Rheem, Ruud, Richmond gas water heater status light codes

125 codes for 57 model series, each with the wording and source from Rheem use and care manuals and the Maximus service manual.

How House Works EditorialChecked against 35 sources,
How it is checked
Methodology
Page
HHW · ERROR-CODES · RHEEM-GAS-TANK
Based on
Rheem use and care manuals and the Maximus service manual

Meanings are quoted from Rheem use and care manuals and the Maximus service manual. The "Who" column is our reading of the remedy in those documents: whether an owner can do the first checks, or the fix belongs to a licensed technician.

Codes with step-by-step checks

How it works: Gas water heater pilot won't stay lit: thermocouple, thermopile and the status light

All Rheem gas tank water heaters codes

CodeMeaningWhoSeriesSource
Status light off“Control Off/Pilot Out”
What to check
Legend on the gas control label, as reproduced in the manual.
Owner checks, then technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
Status light off“Combination Gas Control turned off”
What to check
Owner checks, then technician
5 seriesRheem Performance Series: Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: Atmospheric
AP17110-1 (01/15) p. 24; AP16801-2 (08/14) p. 24; AP23060 Rev 01 p. 24
Status light off“Pilot not lit”
What to check
Owner checks, then technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
Status light off“Insufficient power supply (millivoltage)”
What to check
Technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
Status light off“Combination Gas Control (Thermostat) turned off.”
What to check
Owner checks, then technician
11 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric
5 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP20849 Rev 02 p. 24
Status light steady“Pilot recently extinguished and Thermopile is cooling down Temperature knob recently turned to OFF position”
What to check
Owner checks, then technician
5 seriesRheem Performance Series: Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: Atmospheric
AP17110-1 (01/15) p. 24; AP16801-2 (08/14) p. 24; AP23060 Rev 01 p. 24
Status light steady“Pilot recently extinguished and. Thermopile is cooling down. Temperature knob recently turned to OFF position.”
What to check
Owner checks, then technician
11 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric
5 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP20849 Rev 02 p. 24
1 blink“Normal Operation”
What to check
Legend on the gas control label, as reproduced in the manual; printed in blue, except in AP17110-1 (01/15), which prints no colors.
Owner can check
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
1 blink“Normal Operation Temperature knob in pilot position and pilot is lit”
What to check
Printed in blue, except in AP17110-1 (01/15), which prints no colors.
Owner can check
5 seriesRheem Performance Series: Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: Atmospheric
AP17110-1 (01/15) p. 24; AP16801-2 (08/14) p. 24; AP23060 Rev 01 p. 24
1 blink“Normal Operation. Temperature knob in pilot position and pilot is lit.”
What to check
Printed in blue.
Owner can check
11 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric
5 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP20849 Rev 02 p. 24
2 blinks“Thermopile Voltage Low”
What to check
Legend on the gas control label, as reproduced in the manual; printed in red, except in AP17110-1 (01/15), which prints no colors.
Technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
2 blinks“Low thermopile voltage however pilot is lit”
What to check
Printed in red, except in AP17110-1 (01/15), which prints no colors.
Technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
4 blinks“High Temperature Shutdown”
What to check
Legend on the gas control label, as reproduced in the manual; printed in red, except in AP17110-1 (01/15), which prints no colors.
Technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
4 blinks“High water temperature limit tripped”
What to check
Printed in red, except in AP17110-1 (01/15), which prints no colors.
Technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
5 blinks“Temperature Sensor Failure”
What to check
Legend on the gas control label, as reproduced in the manual; printed in red, except in AP17110-1 (01/15), which prints no colors.
Technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
5 blinks“Water temperature sensor failure”
What to check
Printed in red, except in AP17110-1 (01/15), which prints no colors.
Technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
7 blinks“Gas Control or Valve Failure”
What to check
Legend on the gas control label, as reproduced in the manual; printed in red, except in AP17110-1 (01/15), which prints no colors.
Technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
7 blinks“Combination Gas Control failure”
What to check
Printed in red, except in AP17110-1 (01/15), which prints no colors.
Technician
5 seriesRheem Performance Series: Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: Atmospheric
AP17110-1 (01/15) p. 24; AP16801-2 (08/14) p. 24; AP23060 Rev 01 p. 24
7 blinks“Combination Gas Control (Thermostat) failure.”
What to check
Printed in red.
Technician
11 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric
5 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP20849 Rev 02 p. 24
8 blinks“Flame Sense Error”
What to check
Legend on the gas control label, as reproduced in the manual; printed in red, except in AP17110-1 (01/15), which prints no colors.
Technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
8 blinks“False pilot flame signal”
What to check
Printed in red, except in AP17110-1 (01/15), which prints no colors.
Technician
15 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric
8 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24
9 blinks“Chamber Sensor Failure”
What to check
Legend on the gas control label, as reproduced in the manual; printed in red.
Technician
11 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric
5 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP20849 Rev 02 p. 24
9 blinks“Chamber sensor failure.”
What to check
Printed in red.
Technician
7 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx
AP23698 p. 24; AP22858 p. 23; AP23699 p. 24
9 blinks“Chamber sensor failure or bimetal switch activated.”
What to check
Printed in red.
TechnicianRheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx AtmosphericAP19928 Rev 02 p. 24; AP20849 Rev 02 p. 24
10 blinks“Chamber Temperature Shutdown”
Legend on the gas control label, as reproduced in the manual; printed in red.
Technician
11 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric
5 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP20849 Rev 02 p. 24
10 blinks“Chamber temperature shutdown.”
Printed in red.
Technician
11 seriesRheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric
5 documentsAP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP20849 Rev 02 p. 24
Heartbeat“Call For Heat (no fault conditions)”
Printed as: Heartbeat, alternates bright/dim.
Owner can check
7 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP15696-3 (03/17) p. 28; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32
Heartbeat“Calling For Heat/No Fault Conditions”
Printed as: Heartbeat, alternates bright/dim.
Owner can check
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 24; AP19336 (12/17) p. 25; AP16881-1 (03/17) p. 25; AP15873 (06/10) p. 24; AP17115 (11/13) p. 24
Short flash every 4 seconds“IDLE (no call for heat, no fault conditions)”
Printed as: Short flash once every four seconds.
Owner can check
7 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP15696-3 (03/17) p. 28; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32
Short flash every 4 seconds“Normal Operating Condition/ No Fault Condition”
Printed as: Short flash once every four seconds.
Owner can check
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 24; AP19336 (12/17) p. 25; AP16881-1 (03/17) p. 25; AP15873 (06/10) p. 24; AP17115 (11/13) p. 24
1 flash“Low flame signal”
Printed as: One flash every three seconds; display code 12.
Technician
7 seriesRheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page)
AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP22524 Rev 02 p. 37
1 flash“Low flame signal (control continues to operate)”
Printed as: One Flash, three second pause.
Technician
7 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP15696-3 (03/17) p. 28; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32
1 flash“Control still operating/ Low flame signal”
Printed as: One Flash, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 24; AP19336 (12/17) p. 25; AP16881-1 (03/17) p. 25; AP15873 (06/10) p. 24; AP17115 (11/13) p. 24
2 flashes“Pressure switch failed closed.”
Printed as: Two flashes every three seconds; display code 44; printed as: Two Flash, three second pause.
Technician
14 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Rheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Power Vent, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent, AP22524 Rev 02 (manual not listed on a product page)
7 documentsAP15696-3 (03/17) p. 28; AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32; AP22524 Rev 02 p. 37
2 flashes“Sytem in Lockout/Flue Damper Switch closed”
Printed as: Two Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 24; AP19336 (12/17) p. 25; AP16881-1 (03/17) p. 25; AP15873 (06/10) p. 24; AP17115 (11/13) p. 24
3 flashes“Pressure and/or blower thermal switch failed open.”
What to check
Printed as: Three flashes every three seconds; display code 46.
Technician
7 seriesRheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page)
AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP22524 Rev 02 p. 37
3 flashes“Pressure switch failed open.”
What to check
Printed as: Three Flash, three second pause.
Technician
7 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP15696-3 (03/17) p. 28; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32
3 flashes“System in Lockout/Flue Damper Switch open”
What to check
Printed as: Three Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 24; AP19336 (12/17) p. 25; AP16881-1 (03/17) p. 25; AP15873 (06/10) p. 24; AP17115 (11/13) p. 24
4 flashes“TCO activated.”
Printed as: Four flashes every three seconds; display code 31.
Technician
7 seriesRheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page)
AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP22524 Rev 02 p. 37
4 flashes“TCO limit lockout”
Printed as: Four Flash, three second pause.
Technician
7 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP15696-3 (03/17) p. 28; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32
4 flashes“Flame out of sequence”
Printed as: Four Flash, three second pause.
TechnicianRuud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power VentAP19361 (12/17) p. 32
4 flashes“System in Lockout/ Thermal Cutoff Device tripped”
Printed as: Four Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 24; AP19336 (12/17) p. 25; AP16881-1 (03/17) p. 25; AP15873 (06/10) p. 24; AP17115 (11/13) p. 24
5 flashes“Flame out of sequence”
Printed as: Five flashes every three seconds; display code 14; printed as: Five Flash, three second pause.
Technician
12 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Rheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page)
6 documentsAP15696-3 (03/17) p. 28; AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP15696 (11/10) p. 28; AP22524 Rev 02 p. 37
5 flashes“System in Lockout/No Flame Sense”
Printed as: Five Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 24; AP19336 (12/17) p. 25; AP16881-1 (03/17) p. 25; AP15873 (06/10) p. 24; AP17115 (11/13) p. 24
6-1 flashes“System in lockout. Failed trial for ignitions.”
What to check
Printed as: Six flashes of one, every three seconds; display code 11.
Technician
7 seriesRheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page)
AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP22524 Rev 02 p. 37
6-1 flashes“Failed trial for ignition”
What to check
Printed as: Six-One Flash, three second pause.
Technician
7 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP15696-3 (03/17) p. 28; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32
6-1 flashes“System in Lockout/ Unit failed to light”
What to check
Printed as: Six-One Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 24; AP19336 (12/17) p. 25; AP16881-1 (03/17) p. 25; AP15873 (06/10) p. 24; AP17115 (11/13) p. 24
6-2 flashes“System in lockout. Blower pressure switch and/or thermal switch open.”
Printed as: Six flashes of two, every three seconds; display code 45.
Technician
7 seriesRheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page)
AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP22524 Rev 02 p. 38
6-2 flashes“Recycle limit - PS/limit opened”
Printed as: Six-Two Flash, three second pause.
Technician
7 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP15696-3 (03/17) p. 28; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32
6-2 flashes“System in Lockout/ Flue Damper Switch opened”
Printed as: Six-Two Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 24; AP19336 (12/17) p. 25; AP16881-1 (03/17) p. 25; AP15873 (06/10) p. 24; AP17115 (11/13) p. 24
6-3 flashes“System in lockout. Flame lost.”
Printed as: Six flashes of three, every three seconds; display code 13.
Technician
7 seriesRheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page)
AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP22524 Rev 02 p. 38
6-3 flashes“Recycle limit - flame lost”
Printed as: Six-Three Flash, three second pause.
Technician
7 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP15696-3 (03/17) p. 28; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32
6-3 flashes“System in Lockout/ Flame Lost”
Printed as: Six-Three Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 24; AP19336 (12/17) p. 25; AP16881-1 (03/17) p. 25; AP15873 (06/10) p. 24; AP17115 (11/13) p. 24
6-4 flashes“System in lockout. Flame sense out of sequence.”
Printed as: Six flashes of four, every three seconds; display code 14.
Technician
7 seriesRheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page)
AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP22524 Rev 02 p. 38
6-4 flashes“Soft Lockout - flame out of sequence sensed”
Printed as: Six-Four Flash, three second pause.
Technician
7 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP15696-3 (03/17) p. 28; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32
6-4 flashes“System in Lockout/ Flame sense out of sequence”
Printed as: Six-Four Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 25; AP19336 (12/17) p. 26; AP16881-1 (03/17) p. 26; AP15873 (06/10) p. 25; AP17115 (11/13) p. 25
6-5 flashes“System in lockout. Failed Ignition attempts.”
Printed as: Six flashes of five, every three seconds; display code 10.
Technician
7 seriesRheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page)
AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP22524 Rev 02 p. 38
7 flashes“System in lockout. Flammable vapor sensor.”
What to check
Printed as: Seven flashes every three seconds; display code 47.
Technician
6 seriesRheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent
AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37
7 flashes“System in lockout. Flammable vapour sensor.”
What to check
Printed as: Seven flashes every three seconds; display code 47.
TechnicianAP22524 Rev 02 (manual not listed on a product page)AP22524 Rev 02 p. 38
7 flashes“Flammable vapor sensor lockout”
What to check
Printed as: Seven Flash, three second pause.
TechnicianRuud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power VentAP15696 (11/10) p. 28; AP19361 (12/17) p. 32
7 flashes“System in Lockout/ Presence of Flammable Vapors detected”
What to check
Printed as: Seven Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 25; AP19336 (12/17) p. 26; AP16881-1 (03/17) p. 26; AP15873 (06/10) p. 25; AP17115 (11/13) p. 25
7 flashes“Flammable vapour sensor lockout”
What to check
Printed as: Seven Flash, three second pause.
TechnicianRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced DraftAP15696-3 (03/17) p. 28
8-1 flashes“Flammable vapor sensor, fault detected.”
Printed as: Eight flashes of one, every three seconds; display code 49.
Technician
6 seriesRheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent
AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37
8-1 flashes“Flammable vapour sensor, fault detected.”
Printed as: Eight flashes of one, every three seconds; display code 49.
TechnicianAP22524 Rev 02 (manual not listed on a product page)AP22524 Rev 02 p. 38
8-1 flashes“FVS fault detected”
Printed as: Eight-One Flash, three second pause.
Technician
7 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP15696-3 (03/17) p. 28; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32
8-1 flashes“System in Lockout/ Flammable Vapor Sensor fault detected”
Printed as: Eight-One Flash, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 25; AP19336 (12/17) p. 26; AP16881-1 (03/17) p. 26; AP15873 (06/10) p. 25; AP17115 (11/13) p. 25
8-2 flashes“Temperature sensor fault detected.”
Printed as: Eight flashes of two, every three seconds; display code 89; printed as: Eight-Two Flash, three second pause.
Technician
14 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Rheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Power Vent, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent, AP22524 Rev 02 (manual not listed on a product page)
7 documentsAP15696-3 (03/17) p. 28; AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32; AP22524 Rev 02 p. 38
8-2 flashes“System in Lockout/ Energy cutoff device fault detected”
Printed as: Eight-Two Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 25; AP19336 (12/17) p. 26; AP16881-1 (03/17) p. 26; AP15873 (06/10) p. 25; AP17115 (11/13) p. 25
8-3 flashes“Electronics fault detected.”
Printed as: Eight flashes of three, every three seconds; display code 15; printed as: Eight-Three Flash, three second pause.
Technician
14 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Rheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Power Vent, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent, AP22524 Rev 02 (manual not listed on a product page)
7 documentsAP15696-3 (03/17) p. 28; AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32; AP22524 Rev 02 p. 38
8-3 flashes“System in Lockout/ Fault in the electronics circuit detected”
Printed as: Eight-Three Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 25; AP19336 (12/17) p. 26; AP16881-1 (03/17) p. 26; AP15873 (06/10) p. 25; AP17115 (11/13) p. 25
8-4 flashes“Combination gas control (thermostat) fault detected.”
Printed as: Eight flashes of four, every three seconds; display code 93.
Technician
7 seriesRheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page)
AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP22524 Rev 02 p. 38
8-4 flashes“Valve fault detected”
Printed as: Eight-Four Flash, three second pause.
Technician
7 seriesRheem Professional Classic Plus Series: Induced Draft, Rheem Performance Platinum Induced Draft, Richmond Encore Powered Damper, Richmond Encore XR90 Induced Draft, Ruud Professional Achiever Plus Series: Induced Draft, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP15696-3 (03/17) p. 28; AP15696 (11/10) p. 28; AP19361 (12/17) p. 32
8-4 flashes“System in Lockout/ Fault with the Gas Control (Thermostat)”
Printed as: Eight-Four Flashes, three second pause.
Technician
11 seriesRheem Professional Prestige Series: Powered Damper, Rheem Professional Classic Plus Series: Powered Damper, Ruud Professional Achiever Plus Series: Powered Damper, Ruud Professional Ultra Series: Powered Damper, Rheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Rheem Performance Platinum Series: Powered Damper, Rheem Performance Platinum Series: Ultra Low NOx Powered Damper, AP17115 (11/13) (manual not listed on a product page)
5 documentsAP15756 (05/10) p. 25; AP19336 (12/17) p. 26; AP16881-1 (03/17) p. 26; AP15873 (06/10) p. 25; AP17115 (11/13) p. 25
9 flashes“Chamber sensor fault”
Printed as: Nine Flash, three second pause; printed as: Nine Flashes, three second pause.
Technician
6 seriesRheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP19336 (12/17) p. 26; AP19361 (12/17) p. 32
9-2 flashes“Chamber temperature fault”
Printed as: Nine-Two Flash, three second pause; printed as: Nine -Two Flashes, three second pause.
Technician
6 seriesRheem Professional Prestige Series: Powered Damper Ultra Low NOx, Ruud Professional Achiever Plus Series: Powered Damper Ultra Low NOx, Richmond Encore Atmospheric Ultra Low NOx, Richmond Essential Plus Atmospheric Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx, Ruud Professional Achiever Series: Ultra Low NOx Power Vent
AP19336 (12/17) p. 26; AP19361 (12/17) p. 32
● ○ ○ ○ ○ ●“Unit shuts down and in lockout.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ○ ○ ● ○“Flame signal sensed out of proper sequence.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ○ ○ ● ●“Problem in the gas valve driver circuit.”
LEDs as printed, left to right: ○ ○ ▼ A B C.
Technician
6 seriesRuud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ○ ○ ● ●“Problem in the combination gas valve driver circuit.”
LEDs as printed, left to right: ▼ B C D E F; LEDs as printed, left to right: ○ ○ ▼ A B C.
Technician
7 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx
AP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP16412-2 p. 28
● ○ ○ ○ ● ●“Problem in the combination gas control (thermostat) driver circuit.”
LEDs as printed, left to right: ○ ○ ▼ A B C.
TechnicianRheem Professional Classic Series: Power Direct VentAP22539 Rev 01 p. 47
● ○ ○ ● ○ ○“An open earth ground circuit to the ignition system.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ○ ● ○ ●“Unit shuts down.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ○ ● ● ○“System in lockout.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ○ ● ● ●“ECO activated.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ● ○ ○ ○“Pressure switch remained closed longerthan 5 seconds after the call for heat began.”
LEDs as printed, left to right: ○ ○ ▼ A B C.
TechnicianRuud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power VentAP17505-1 (03/17) p. 35
● ○ ● ○ ○ ○“Pressure switch remained closed longer than 5 seconds after the call for heat began.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
9 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
5 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ● ○ ○ ●“Pressure switch remained open longer than 5 seconds after the combustion blower was energized.”
LEDs as printed, left to right: ○ ○ ▼ A B C.
Technician
6 seriesRuud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ● ○ ○ ●“Pressure switch remained opened longer than 5 seconds after the combustion blower was energized.”
LEDs as printed, left to right: ▼ B C D E F; LEDs as printed, left to right: ○ ○ ▼ A B C.
Technician
7 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx
AP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP16412-2 p. 28
● ○ ● ○ ● ○“Wiring error or a high resistance to earth ground.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ● ○ ● ●“Error in the hot surface ignitor circuit.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ● ● ○ ○“One of the temperature adjust buttons stuck closed.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ● ● ○ ●“Water temperature sensor is either open or short circuited.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ○ ● ● ● ○“Problem with the internal circuit.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
● ● ● ● ● ●“Problem with the internal circuit.”
LEDs as printed, left to right: ○ ○ ▼ A B C; LEDs as printed, left to right: ▼ B C D E F.
Technician
12 seriesRheem Professional Classic Plus Series: Power Direct Vent, Rheem Professional Classic Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Power Direct Vent, Rheem Professional Classic Series: Power Direct Vent, Richmond Essential Plus Series: Heavy Duty Power Direct Vent, Ruud Professional Achiever Plus Series: Heavy Duty Power Vent, Richmond Essential Series: Power Vent, Richmond Essential Plus Series: Heavy Duty Power Vent, Ruud Professional Achiever Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Power Vent, AP22670 (manual not listed on a product page)
6 documentsAP14896-2 (12/10) p. 39; AP14896-3 (06/11) p. 42; AP17505-1 (03/17) p. 35; AP16412-2 p. 27; AP15762 (04/10) p. 32; AP22670 p. 32
A001“Ignition lockout due to a total of 9 consecutive failed ignitions. This will disable the heater.”
What to check
Owner checks, then technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 42; AP21833 Rev 02 p. 42; AP21831 Rev 02 p. 42; AP23008 Rev 03 p. 35
A002“Flame not stable lockout. Lost flame three times during one heat cycle. This will disable the heater.”Owner checks, then technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 42; AP21833 Rev 02 p. 42; AP21831 Rev 02 p. 42; AP23008 Rev 03 p. 35
A003“The intake pressure switch was detected open when the blower was running. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 42; AP21833 Rev 02 p. 42; AP21831 Rev 02 p. 42; AP23008 Rev 03 p. 35
A004“The proof of air flow switch was detected open during heating operation. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 42; AP21833 Rev 02 p. 42; AP21831 Rev 02 p. 42; AP23008 Rev 03 p. 35
A005“The proof of air flow switch was detected open during pre-purge operation. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 42; AP21833 Rev 02 p. 42; AP21831 Rev 02 p. 42; AP23008 Rev 03 p. 35
A006“The proof of air flow switch was detected open during post purge operation.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 42; AP21833 Rev 02 p. 42; AP21831 Rev 02 p. 42; AP23008 Rev 03 p. 35
A007“Exhaust flue pressure switch was detected open during heating. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 42; AP21833 Rev 02 p. 42; AP21831 Rev 02 p. 42; AP23008 Rev 03 p. 35
A008“The proof of air flow pressure switch was detected closed before the blower started operation. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 42; AP21833 Rev 02 p. 42; AP21831 Rev 02 p. 42; AP23008 Rev 03 p. 35
A010“Ignition Control Test Failure during End of Line (EOL) test”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 42; AP21833 Rev 02 p. 42; AP21831 Rev 02 p. 42; AP23008 Rev 03 p. 35
A012“Flame Detected During Standby/Disabled Mode”Owner checks, then technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 43; AP21833 Rev 02 p. 42; AP21831 Rev 02 p. 42; AP23008 Rev 03 p. 35
A016“Energy Cutout (ECO) switch is open. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 43; AP21833 Rev 02 p. 43; AP21831 Rev 02 p. 43; AP23008 Rev 03 p. 36
A017“Flue (exhaust) gas temperature has exceeded 155°F. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 43; AP21833 Rev 02 p. 43; AP21831 Rev 02 p. 43; AP23008 Rev 03 p. 36
A018“Flue temperature sensor (thermistor) detected open. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 43; AP21833 Rev 02 p. 43; AP21831 Rev 02 p. 43; AP23008 Rev 03 p. 36
A019“Flue temperature sensor (thermistor) detected short circuited. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 43; AP21833 Rev 02 p. 43; AP21831 Rev 02 p. 43; AP23008 Rev 03 p. 36
A022“Upper tank temperature sensor detected open. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 43; AP21833 Rev 02 p. 43; AP21831 Rev 02 p. 43; AP23008 Rev 03 p. 36
A023“Upper tank temperature has exceeded 205°F. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 43; AP21833 Rev 02 p. 43; AP21831 Rev 02 p. 43; AP23008 Rev 03 p. 36
A024“Upper tank temperature sensor detected short circuited. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 43; AP21833 Rev 02 p. 43; AP21831 Rev 02 p. 43; AP23008 Rev 03 p. 36
A025“Control does not detect blower RPM. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44; AP23008 Rev 03 p. 37
A026“Blower RPM feedback (actual RPM) is ≥300 RPM from desired RPM for > 1 minute.”Technician
10 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44
A027“Flame current detected prior to opening gas valve. This will disable the heater.”Owner checks, then technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44; AP23008 Rev 03 p. 37
A028“Flame current detected 10 seconds after closing gas valve. This will disable the heater.”Owner checks, then technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44; AP23008 Rev 03 p. 37
A030“Unit lost flame.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44; AP23008 Rev 03 p. 37
A033“Exhaust flue thermistor analog to digital converter fault. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44; AP23008 Rev 03 p. 37
A034“Upper tank thermistor analog to digital converter fault. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44; AP23008 Rev 03 p. 37
A036“Gas relay #1 stuck closed. This could inadvertently allow the gas valve to open. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44; AP23008 Rev 03 p. 37
A037“Gas relay #2 contacts failed to properly close. This can cause gas valve cycling and gas buildup in the burn chamber. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44; AP23008 Rev 03 p. 37
A038“Gas relay #2 stuck closed. This could inadvertently allow the gas valve to open. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 45; AP21833 Rev 02 p. 45; AP21831 Rev 02 p. 45; AP23008 Rev 03 p. 38
A039“This is a control board hardware fault and requires control board replacement if persistent. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 45; AP21833 Rev 02 p. 45; AP21831 Rev 02 p. 45; AP23008 Rev 03 p. 38
A040“This is a control board hardware fault and requires control board replacement if persistent. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 45; AP21833 Rev 02 p. 45; AP21831 Rev 02 p. 45; AP23008 Rev 03 p. 38
A041“This is a control board hardware fault and requires control board replacement if persistent. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 45; AP21833 Rev 02 p. 45; AP21831 Rev 02 p. 45; AP23008 Rev 03 p. 38
A042“This is a control board hardware fault and requires control board replacement if persistent. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 45; AP21833 Rev 02 p. 45; AP21831 Rev 02 p. 45; AP23008 Rev 03 p. 38
A043“This is a control board hardware fault and requires control board replacement if persistent. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 45; AP21833 Rev 02 p. 45; AP21831 Rev 02 p. 45; AP23008 Rev 03 p. 38
A044“Input power frequency not 60 Hz. (outside allowable deviation). This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 45; AP21833 Rev 02 p. 45; AP21831 Rev 02 p. 45; AP23008 Rev 03 p. 38
A101“This is a display board hardware fault and requires control board replacement if persistent. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 45; AP21833 Rev 02 p. 45; AP21831 Rev 02 p. 45; AP23008 Rev 03 p. 38
A102“Set the internal clock time.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 45; AP21833 Rev 02 p. 45; AP21831 Rev 02 p. 45; AP23008 Rev 03 p. 38
A103“This is a display board hardware fault and requires control board replacement if persistent. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 45; AP21833 Rev 02 p. 45; AP21831 Rev 02 p. 45; AP23008 Rev 03 p. 38
A104“Presence of water detected by the leak sensor in the bottom pan. If water is seen locate source and take appropriate action to correct the issue. This may disable the heater based on configuration settings.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 45; AP21833 Rev 02 p. 46; AP21831 Rev 02 p. 46; AP23008 Rev 03 p. 39
A108“Communication lost between the display board and the ignition control board. The ignition control board will continue to operate the heater using the last known configuration settings. Check wiring between the display and P5 of the ignition control board.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 46; AP21833 Rev 02 p. 46; AP21831 Rev 02 p. 46; AP23008 Rev 03 p. 39
A110“Monthly test of automatic shutoff valve (premium models only) was not completed properly. The valve did not close in the allotted time.”Technician
10 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense
AP23779 p. 46; AP21833 Rev 02 p. 46; AP21831 Rev 02 p. 46
A110“The automatic, reoccurring test of the shutoff valve (premium models only) was not completed properly. The valve did not close in the allotted time.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 39
A111“Monthly test of automatic shutoff valve (premium models only) was not completed properly. The valve did not open in the allotted time. This will disable the heater.”Technician
10 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense
AP23779 p. 46; AP21833 Rev 02 p. 46; AP21831 Rev 02 p. 46
A111“The automatic, reoccurring test of the shutoff valve (premium models only) was not completed properly. The valve did not open in the allotted time. This will disable the heater.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 39
A112“Automatic shutoff valve (premium models only) is closed. This will disable the heater.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 46; AP21833 Rev 02 p. 46; AP21831 Rev 02 p. 46; AP23008 Rev 03 p. 39
A143“The switch information on the Shutoff Valve is indicating incorrect information such as both switches are OPEN or both switches are CLOSED.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 47; AP21833 Rev 02 p. 47; AP21831 Rev 02 p. 47; AP23008 Rev 03 p. 42
A200“Software versions between the Display Control and Ignition Control are incompatible.”Technician
10 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense
AP23779 p. 47; AP21833 Rev 02 p. 47; AP21831 Rev 02 p. 47
A200“Incompatible Ignition Control SW The ignition control and display are incompatible with each other. Contact technical support.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 42
T020“Lower tank (inlet) temperature sensor (thermistor) detected open.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 43; AP21833 Rev 02 p. 43; AP21831 Rev 02 p. 43; AP23008 Rev 03 p. 36
T021“Lower tank (inlet) temperature sensor (thermistor) detected short circuited.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 43; AP21833 Rev 02 p. 43; AP21831 Rev 02 p. 43; AP23008 Rev 03 p. 36
T026“Blower RPM feedback (actual RPM) is ≥300 RPM from desired RPM for > 1 minute.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 37
T029“Unit did not light.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44; AP23008 Rev 03 p. 37
T032“Lower (inlet) thermistor analog to digital converter fault.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44; AP23008 Rev 03 p. 37
T035“Gas relay #1 contacts did not close. The unit will continue to try and close the relay to initiate combustion.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 44; AP21833 Rev 02 p. 44; AP21831 Rev 02 p. 44; AP23008 Rev 03 p. 37
T046“Number of Anodes Mismatch”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 38
T105“Check to see if leak sensor is installed in the bottom pan. Check wiring on connector P11 of the ignition control board.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 46; AP21833 Rev 02 p. 46; AP21831 Rev 02 p. 46; AP23008 Rev 03 p. 39
T113“Peak flame rod current has deviated from the startup average. This is indicative of degradation of the flame rod (dirty, sooty). It needs to be cleaned and inspected .”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 46; AP21833 Rev 02 p. 46; AP21831 Rev 02 p. 46; AP23008 Rev 03 p. 39
T114“Peak flame rod current has deviated from the startup average by a significant amount. Clean and inspect flame rod. Replace if necessary.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 46; AP21833 Rev 02 p. 46; AP21831 Rev 02 p. 46; AP23008 Rev 03 p. 39
T115“Monitored characteristics of the combustion system indicate degraded performance. Combustion system needs to be inspected and serviced.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 46; AP21833 Rev 02 p. 46; AP21831 Rev 02 p. 46; AP23008 Rev 03 p. 39
T116“Monitored characteristics of the combustion system indicate severely degraded performance. Combustion system needs to be inspected and serviced.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 46; AP21833 Rev 02 p. 46; AP21831 Rev 02 p. 46; AP23008 Rev 03 p. 39
T117“Periodic maintenance, inspection, and upkeep on the unit.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 46; AP21833 Rev 02 p. 47; AP21831 Rev 02 p. 47; AP23008 Rev 03 p. 39
T118“Periodic maintenance, inspection, and upkeep on the unit.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 47; AP21833 Rev 02 p. 47; AP21831 Rev 02 p. 47; AP23008 Rev 03 p. 39
T119“Periodic maintenance, inspection, and upkeep on the unit.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 47; AP21833 Rev 02 p. 47; AP21831 Rev 02 p. 47; AP23008 Rev 03 p. 40
T120“Periodic maintenance, inspection, and upkeep on the unit.”Technician
11 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page)
AP23779 p. 47; AP21833 Rev 02 p. 47; AP21831 Rev 02 p. 47; AP23008 Rev 03 p. 40
T121“No water detected in Tank due to anode signal(s) being OPEN circuited.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 40
T122“The Display Control is no longer receiving information about the Powered Anodes from the Powered Anode Module.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 40
T123“Upper Anode "open" circuit which could be caused by wiring damage, wiring disconnected or anode damage.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 40
T125“Upper Anode "short" circuited which could be caused by wiring damage, anode damage or the anode is in contact with the tank. This is not a connector issue and not caused from leaking. This can only be a failed anode.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 40
T126“Upper Anode power ≥ 100% and has reached its protective limit.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 41
T127“Upper Anode power > 87% but < 100%. The anode is approaching its protective limit.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 41
T128“Middle Anode "open" circuit which could be caused by wiring damage, wiring disconnected or anode damage.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 41
T130“Middle Anode "short" circuited which could be caused by wiring damage, anode damage or the anode is in contact with the tank. This is not a connector issue and not caused from leaking. This can only be a failed anode.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 41
T131“Middle Anode power ≥ 100% and has reached its protective limit.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 41
T132“Middle Anode power > 87% but < 100%. The anode is approaching its protective limit.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 41
T133“Lower Anode "open" circuit which could be caused by wiring damage, wiring disconnected or anode damage.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 41
T135“Lower Anode "short" circuited which could be caused by wiring damage, anode damage or the anode is in contact with the tank. This is not a connector issue and not caused from leaking. This can only be a failed anode.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 41
T136“Lower Anode power ≥ 100% and has reached its protective limit.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 42
T137“Lower Anode power > 87% but < 100%. The anode is approaching its protective limit.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 42
T138“Anode #4 "open" circuit which could be caused by wiring damage, wiring disconnected or anode damage.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 42
T140“Anode #4 "short" circuited which could be caused by wiring damage, anode damage or the anode is in contact with the tank. This is not a connector issue and not caused from leaking. This can only be a failed anode.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 42
T141“Anode #4 power ≥ 100% and has reached its protective limit.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 42
T142“Anode #4 power > 87% but < 100%. The anode is approaching its protective limit.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 42
T150“Percentage of Successful Ignitions Low The water heater has experienced a higher number of failed ignitions that expected.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 42
T151“Flame Current Deviation Too High The flame current detected has deviated outside the expected range.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 42
T152“Blower Motor Deviation Too High The blower motor PWM signal has deviated outside the expected range.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 42
T504“WiFi chip communication timing error. This doesn't mean the chip has failed.”Technician
10 seriesRheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense
AP23779 p. 47; AP21833 Rev 02 p. 47; AP21831 Rev 02 p. 47
T504“WiFi Chip Communication Error. Refer to the use and care manual for information, or contact technical support or service provider.”TechnicianAP23008 Rev 03 (manual not listed on a product page)AP23008 Rev 03 p. 42

What to check, code by code

Rheem water heater status light off: control off or pilot out

Checked

Status light, gas valve LED or display

Status light off

“Control Off/Pilot Out”

Owner checks, then technician

Printed on 15 model series · 8 documents

Rheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric · AP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24

Legend on the gas control label, as reproduced in the manual.

Short answer On Rheem, Ruud and Richmond status light models, a dark light means the gas control is off, the pilot is out, or millivoltage is too low. Turn the control on or relight the pilot by the label; thermopile checks are technician work. See what to check

What it means

Rheem’s table gives a dark status light three possible conditions, in this order: “Combination Gas Control turned off”, “Pilot not lit” and “Insufficient power supply (millivoltage)” (AP23060 Rev 01, p. 24). The label legend sums them up as “Control Off/Pilot Out”. The Ultra Low NOx manuals word the first one “Combination Gas Control (Thermostat) turned off.” (AP23699, p. 24).

The light also goes dark on purpose. When you turn the knob to OFF, the STATUS light “will briefly stay lit, then go off after a short period of time” (AP23060 Rev 01, p. 17). And when you light the pilot, you hold the knob in until the STATUS light begins to blink (AP23060 Rev 01, p. 17). With the knob at OFF, a dark light is what the label describes.

The NOTICE above the table sets the order: “If pilot is not lit and the status light is not blinking or constantly on, follow the lighting instructions”, then read the code once the light blinks (AP23060 Rev 01, p. 24).

Check these first

In the table’s order, with the steps from the lighting label in the same manual:

  1. Smell for gas before lighting: all around the heater and next to the floor, because some gas is heavier than air (AP23060 Rev 01, p. 17). If you smell gas, stop and follow the steps at the top of this page.
  2. If the knob is at OFF, the table’s fix is to follow the operating instructions to turn the gas control on (AP23060 Rev 01, p. 24). In this manual the operating instructions start with the lighting label (AP23060 Rev 01, pp. 2, 17).
  3. Light the pilot by the label. Turn the knob to OFF and wait five minutes; remove the outer door, but not the inner door; turn the knob to PILOT; hold it all the way in and press the piezo button several times until the STATUS light begins to blink; check the pilot flame through the sight glass (AP23060 Rev 01, p. 17).
  4. If the STATUS light has not started blinking after 90 seconds and the pilot is not lit, the label says to repeat steps 2 through 6. If the pilot will not stay lit after several attempts, turn the knob to OFF and call your service technician or gas supplier (AP23060 Rev 01, p. 17).
  5. The label’s last steps are to replace the outer door, release the knob (it should pop back out) and set the knob to the temperature you want. If the knob does not pop back out, stop and immediately call your service technician or gas supplier (AP23060 Rev 01, p. 17).
  6. If the pilot lights but goes out when you let go of the knob, the NOTICE says to repeat the lighting instructions and keep the knob depressed until the pilot is lit and the code can be fully read (AP23060 Rev 01, p. 24). Two red blinks, for example, mean low thermopile voltage; see 2 blinks.

When to call a licensed technician

  • Low millivoltage. The table’s checks for it are the thermopile connector at the gas control, the thermopile wires (replaced if damaged) and the pilot assembly (AP23060 Rev 01, p. 24). Rheem’s chart also lists a disconnected thermopile as the first cause of a pilot that goes out when the knob is released and says to make sure the connectors at the gas control are connected properly (AP23060 Rev 01, p. 22). We list this work for a technician because it is on the gas control and the pilot. The table calls this condition “Insufficient power supply (millivoltage)”.
  • A pilot that will not stay lit. The chart’s other causes are a defective thermopile, a defective safety magnet, an opened single use gas shut-off device in the gas control, and a tripped combustion shutoff device. Each goes to a qualified service technician, and the two gas control causes mean replacing the gas control (AP23060 Rev 01, p. 22).
  • A pilot that will not light. The chart names air in the gas line, a clogged pilot orifice and a pinched or clogged pilot tube, all for a qualified service technician (AP23060 Rev 01, p. 22).

The manual’s CAUTION on the same page says not to attempt repair of gas piping, the gas control, burners, vent connectors or other safety devices (AP23060 Rev 01, p. 22).

Notes for different models

The status light table is in the manuals for the Performance and Performance Plus Atmospheric and Ultra Low NOx lines and the Ultra Low NOx Skinny, High BTU, High Demand and Heavy Duty models. It is on page 24 of AP23060 Rev 01, AP16801-2 (08/14), AP17110-1 (01/15), AP23698, AP23699, AP20849 Rev 02 and AP19928 Rev 02, and on page 23 of AP22858.

  • AP17110-1 (01/15) prints no colors, and its note says “If the Status Light is not blinking, relight the Pilot.” (AP17110-1, p. 24).
  • The charts in AP19928 Rev 02, AP20849 Rev 02, AP23698 and AP23699 describe a pilot that does not stay lit “when the BLACK button is released” (AP23699, p. 22), while their lighting labels describe a knob (AP23699, p. 17). Follow the label on your heater, as the table itself says (AP23060 Rev 01, p. 24).
  • Power vent, powered damper and induced draft models have a gas valve LED, and their LED tables have no row for an unlit LED (AP22511 Rev 02, p. 37; AP15756, pp. 24–25).
  • The Professional Classic Series: Atmospheric has no status light table. Its chart says the pilot burner may be out when there is not enough or no hot water, and to relight it by the “Lighting The Water Heater” section (AP22543 Rev 04, p. 22).

Related codes: Status light steady, 1 blink, 2 blinks. All Rheem gas tank water heaters codes

Rheem water heater status light stays on: pilot recently out or knob just turned off

Checked

Status light, gas valve LED or display

Status light steady

“Pilot recently extinguished and Thermopile is cooling down Temperature knob recently turned to OFF position”

Owner checks, then technician

Printed on 5 model series · 3 documents

Rheem Performance Series: Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: Atmospheric · AP17110-1 (01/15) p. 24; AP16801-2 (08/14) p. 24; AP23060 Rev 01 p. 24

Short answer On Rheem, Ruud and Richmond status light models, a light that stays on without blinking means the pilot recently went out and the thermopile is cooling down, or the knob was just turned to OFF. Rheem's fix is to light the pilot by the label. See what to check

What it means

Rheem’s table calls this state “Constantly lit” and gives it two causes: the pilot recently went out and the thermopile is cooling down, or the temperature knob was recently turned to OFF (AP23060 Rev 01, p. 24). The light does not blink, so it is not a count.

The table prints no color for this row (AP23060 Rev 01, p. 24). The note under the label legend says that when the knob is turned to OFF with the pilot lit, the status light “will briefly stay lit and turn from blue to red” (AP23060 Rev 01, p. 24), and the lighting label says it will “briefly stay lit, then go off after a short period of time” (AP23060 Rev 01, p. 17). A steady light right after you turned the knob to OFF is that sequence. “Solid red” is not printed as a code in any of the current Rheem manuals collected for this site.

Check these first

The table’s remedy is the same for both causes: “Follow the lighting instructions as detailed on the water heater and it’s Use & Care manual to light the pilot” (AP23060 Rev 01, p. 24).

  1. If you smell gas, stop and follow the steps at the top of this page. The label says to smell all around the heater and next to the floor before lighting (AP23060 Rev 01, p. 17).
  2. If you turned the knob to OFF yourself, the light staying on for a short time and then going off is what the label describes (AP23060 Rev 01, p. 17).
  3. If the pilot went out, light it by the label. It starts with the knob at OFF and a five-minute wait to clear out any gas; then the knob goes to PILOT and you hold it in while pressing the piezo button until the STATUS light begins to blink (AP23060 Rev 01, p. 17).
  4. If the pilot lights but goes out when you release the knob, repeat the lighting instructions and keep the knob depressed until the code can be fully read, as the NOTICE says (AP23060 Rev 01, p. 24). The code then tells you more; low thermopile voltage, for example, is 2 blinks.
  5. If the pilot will not stay lit after several attempts, turn the knob to OFF and call your service technician or gas supplier (AP23060 Rev 01, p. 17).

When to call a licensed technician

  • A pilot that keeps going out. Rheem’s chart lists a disconnected thermopile (make sure its connectors at the gas control are connected properly), a defective thermopile, a defective safety magnet, an opened single use gas shut-off device in the gas control and a tripped combustion shutoff device. The chart names a qualified service technician for all but the first; we list the first for a technician too, because the connectors are on the gas control (AP23060 Rev 01, p. 22).
  • A pilot that is lit while the light stays on without blinking. The table has no row for that and gives the owner no step; the manual’s “If you need service” page lists who to call (AP23060 Rev 01, p. 28).
  • Any repair of the gas control, burners or other safety devices, which the CAUTION on the troubleshooting page refers to qualified service personnel (AP23060 Rev 01, p. 22).

Notes for different models

The “Constantly lit” row is in all eight status light manuals: AP23060 Rev 01, AP16801-2 (08/14), AP17110-1 (01/15), AP23698, AP23699, AP20849 Rev 02 and AP19928 Rev 02 on page 24, and AP22858 on page 23.

  • AP17110-1 (01/15) drops the color from the legend note: “If Pilot is lit, Status Light will briefly stay lit when Knob is turned to OFF.” (AP17110-1, p. 24).
  • On power vent, powered damper and induced draft models the gas valve LED has no steady state in its table. The normal states there are a short flash once every four seconds and a “heartbeat” that alternates bright and dim (AP15756, p. 24).
  • Manuals without a status light table, such as the one for the Professional Classic Series: Atmospheric, print no “Constantly lit” row (AP22543 Rev 04, pp. 21–22).

Related codes: Status light off, 1 blink, 2 blinks. All Rheem gas tank water heaters codes

Checked

Status light, gas valve LED or display

2 blinks

“Thermopile Voltage Low”

Technician

Printed on 15 model series · 8 documents

Rheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric · AP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24

Legend on the gas control label, as reproduced in the manual; printed in red, except in AP17110-1 (01/15), which prints no colors.

Short answer On Rheem, Ruud and Richmond status light models, two red blinks every three seconds mean low thermopile voltage with the pilot lit. The table's fixes at the thermopile and pilot are technician work. Power vent and powered damper LEDs use two flashes differently. See what to check

Two red blinks every three seconds is the label’s “Thermopile Voltage Low”. The table under it is more exact: “Low thermopile voltage however pilot is lit” (AP23060 Rev 01, p. 24). The pilot is burning, but the thermopile voltage is low.

The same table has a second thermopile row. “Insufficient power supply (millivoltage)” is one of the causes of a light that is off, and its checks are the same three as for two blinks: the thermopile connector at the gas control, the thermopile wires, and the pilot assembly (AP23060 Rev 01, p. 24). That case has its own page: status light off.

The table gives this row no step that stops short of the thermopile and the pilot, so the owner’s part is short:

  1. If you smell gas, stop and follow the steps at the top of this page.
  2. Read the code with the pilot lit: two red blinks every three seconds (AP23060 Rev 01, p. 24). AP17110-1 (01/15) prints no colors, so on that manual count the blinks only (AP17110-1, p. 24).
  3. If the pilot goes out and will not stay lit after several attempts at the lighting label, turn the knob to OFF and call your service technician or gas supplier (AP23060 Rev 01, p. 17).
  4. Have the model and serial number from the rating plate ready, and call your installer, plumbing contractor or service agency first; the manual lists Rheem’s Manufacturer’s National Service Department at 1-866-279-4566 as the next step (AP23060 Rev 01, p. 28).
  • The table’s three checks: “Check thermopile connector to the Combination Gas Control to ensure it is properly connected”, check the thermopile wires for damage and replace them if needed, and inspect the pilot assembly (AP23060 Rev 01, p. 24). We list these for a technician: the connector is on the gas control, and the CAUTION on the troubleshooting page refers repairs of the gas control, burners and other safety devices to qualified service personnel (AP23060 Rev 01, p. 22).
  • A defective thermopile. Rheem’s chart says it “should be replaced by a qualified service technician” (AP23060 Rev 01, p. 22).

The status light manuals give no millivolt value for this code, so this page gives none.

Two means different things on Rheem’s indicators:

Indicator and manuals What two means
Status light: AP23060 Rev 01, AP16801-2 (08/14), AP17110-1 (01/15), AP23698, AP23699, AP20849 Rev 02, AP19928 Rev 02, p. 24; AP22858, p. 23 “Low thermopile voltage however pilot is lit”
Power vent gas valve LED: AP22511 Rev 02, AP23058 Rev 01, AP23057 Rev 01, p. 37 “Pressure switch failed closed.” (LCD code 44)
Powered damper gas valve LED: AP15756 (05/10), p. 24 “Sytem in Lockout/Flue Damper Switch closed” (typo as printed)
Induced draft gas valve LED: AP15696-3 (03/17), AP15696 (11/10), p. 28. Also the Ruud manual AP19361 (12/17), p. 32 “Pressure switch failed closed”

On the power vent models the fixes are the blower pressure switch wiring and replacing the blower assembly (AP22511 Rev 02, p. 37). On the powered damper models they are the flue damper wiring and connections, replacing the flue damper assembly, and a qualified service technician (AP15756, p. 24). Both are technician work.

The six-LED panels and the Maximus display have no two-count code. Manuals without a status light table, such as the Professional Classic Series: Atmospheric, do not describe two blinks (AP22543 Rev 04, pp. 21–22).

Related codes: Status light off, Status light steady, 8 blinks. All Rheem gas tank water heaters codes

Checked

Status light, gas valve LED or display

5 blinks

“Temperature Sensor Failure”

Technician

Printed on 15 model series · 8 documents

Rheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric · AP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24

Legend on the gas control label, as reproduced in the manual; printed in red, except in AP17110-1 (01/15), which prints no colors.

Short answer On Rheem, Ruud and Richmond status light models, five red blinks every three seconds mean water temperature sensor failure; Rheem's only step is to contact a qualified service technician. On power vent and powered damper LEDs, five flashes mean something else. See what to check

Five red blinks every three seconds is the label’s “Temperature Sensor Failure”. The table under it says “Water temperature sensor failure”, and its remedy is “Contact a qualified service technician. See “IF YOU NEED SERVICE” on page 28” (AP23060 Rev 01, p. 24). The Ultra Low NOx manuals print the same row (AP23699, p. 24; AP22858, p. 23).

The status light manuals say nothing more about this sensor: not where it is, and not what the control does while the code shows.

The manual gives the owner one step for five blinks: contact a qualified service technician (AP23060 Rev 01, p. 24).

  1. If you smell gas, stop and follow the steps at the top of this page.
  2. Read the code with the pilot lit, as the NOTICE above the table says, and count the red blinks in one three-second cycle (AP23060 Rev 01, p. 24).
  3. Have the model and serial number from the rating plate ready. Call your installer, plumbing contractor or service agency first; the manual lists Rheem’s Manufacturer’s National Service Department at 1-866-279-4566 as the next step (AP23060 Rev 01, p. 28).
  • For the code itself. Every status light manual gives five blinks the same remedy (AP23060 Rev 01, p. 24; AP19928 Rev 02, p. 24).
  • For any work on the gas control or its sensors. The manual’s CAUTION refers repairs of the gas control and other safety devices to qualified service personnel (AP23060 Rev 01, p. 22), and replacing a defective gas control is a job for a qualified service technician (AP23060 Rev 01, p. 23).

Five means different things on Rheem’s indicators, and none of the gas valve LED tables uses it for a temperature sensor:

Indicator and manuals What five means Table’s fix
Status light: AP23060 Rev 01, AP16801-2 (08/14), AP17110-1 (01/15), AP23698, AP23699, AP20849 Rev 02, AP19928 Rev 02, p. 24; AP22858, p. 23 “Water temperature sensor failure” Contact a qualified service technician
Power vent gas valve LED: AP22511 Rev 02, AP23058 Rev 01, AP23057 Rev 01, p. 37 “Flame out of sequence” (LCD code 14) Replace the combination gas control (thermostat)
Induced draft gas valve LED: AP15696-3 (03/17), AP15696 (11/10), p. 28 “Flame out of sequence”; cause “Pilot or burner valve has failed open” Replace the gas control
Powered damper gas valve LED: AP15756 (05/10), p. 24 “System in Lockout/No Flame Sense”; cause “Pilot and/or Main Burner valve has failed to open” Replace the Gas Control (Thermostat)

AP19361 (12/17) has no five-flash row; it prints its “Flame out of sequence” row as four flashes (AP19361, p. 32). In the power vent table, LCD code 14 is printed both for five flashes and for six flashes of four (AP22511 Rev 02, p. 37).

Temperature sensor codes on the other indicators:

  • Power vent, induced draft and AP19361 (12/17) gas valve LEDs: 8-2 flashes, “Temperature sensor fault detected.” The fixes are the wiring at the gas control’s thermal well and replacing the thermal well (AP22511 Rev 02, p. 37; AP15696-3, p. 28). On the powered damper models 8-2 flashes means “System in Lockout/ Energy cutoff device fault detected” instead (AP15756, p. 25).
  • Six-LED panels: the pattern ● ○ ● ● ○ ●, “Water temperature sensor is either open or short circuited.” (AP17505-1, p. 35).
  • Maximus display: A022 and A024 for the upper tank sensor, T020 and T021 for the lower tank (inlet) sensor (AP21833 Rev 02, p. 43).

Related codes: 8-2 flashes, ● ○ ● ● ○ ●, A022. All Rheem gas tank water heaters codes

Checked

Status light, gas valve LED or display

8 blinks

“Flame Sense Error”

Technician

Printed on 15 model series · 8 documents

Rheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Richmond Essential Series: Atmospheric, Rheem Performance Plus Series: Atmospheric, Rheem Performance Plus Series: Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric, Rheem Performance Series: Atmospheric · AP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP16801-2 (08/14) p. 24; AP17110-1 (01/15) p. 24; AP20849 Rev 02 p. 24; AP23060 Rev 01 p. 24

Legend on the gas control label, as reproduced in the manual; printed in red, except in AP17110-1 (01/15), which prints no colors.

Short answer On Rheem, Ruud and Richmond status light models, eight red blinks every three seconds mean a false pilot flame signal (Flame Sense Error); Rheem's only step is to contact a qualified service technician. Gas valve LED tables have no plain eight-flash code. See what to check

Eight red blinks every three seconds is the label’s “Flame Sense Error”. The table under it says “False pilot flame signal”, and its remedy is “Contact a qualified service technician. See “IF YOU NEED SERVICE” on page 28” (AP23060 Rev 01, p. 24). The Ultra Low NOx manuals print the same row (AP23699, p. 24; AP22858, p. 23).

The status light manuals give no cause and no check beyond the row.

The manual gives the owner one step for eight blinks: contact a qualified service technician (AP23060 Rev 01, p. 24).

  1. If you smell gas, stop and follow the steps at the top of this page.
  2. Read the code with the pilot lit, as the NOTICE above the table says (AP23060 Rev 01, p. 24).
  3. Have the model and serial number from the rating plate ready. Call your installer, plumbing contractor or service agency first; the manual lists Rheem’s Manufacturer’s National Service Department at 1-866-279-4566 as the next step (AP23060 Rev 01, p. 28).
  • For the code itself, in every status light manual (AP23060 Rev 01, p. 24; AP20849 Rev 02, p. 24).
  • For any work on the pilot, the burner or the gas control. Cleaning the burner “must be performed only by qualified service personnel”, and the burner chamber is a sealed area whose access door gasket must be replaced if the door is removed (AP23060 Rev 01, p. 21). The troubleshooting CAUTION refers repairs of the gas control and other safety devices to qualified service personnel (AP23060 Rev 01, p. 22).

The gas valve LED tables have no plain eight-flash code. They use two-number codes from 8-1 to 8-4, and the powered damper manuals word them differently:

Code Power vent: AP22511 Rev 02, AP23058 Rev 01, AP23057 Rev 01, p. 37 Powered damper: AP15756 (05/10), p. 25 Induced draft: AP15696-3 (03/17), p. 28
8-1 flashes “Flammable vapor sensor, fault detected.” “System in Lockout/ Flammable Vapor Sensor fault detected” “FVS fault detected”
8-2 flashes “Temperature sensor fault detected.” “System in Lockout/ Energy cutoff device fault detected” “Temperature sensor fault detected”
8-3 flashes “Electronics fault detected.” “System in Lockout/ Fault in the electronics circuit detected” “Electronics fault detected”
8-4 flashes “Combination gas control (thermostat) fault detected.” “System in Lockout/ Fault with the Gas Control (Thermostat)” “Valve fault detected”

For 8-4 flashes the tables start with cycling the power to the gas control and then replacing it (AP22511 Rev 02, p. 37; AP15756, p. 25). They sit under cautions about servicing controls, so these are technician steps.

Codes on the other indicators that also concern a flame signal at the wrong time:

  • Power vent gas valve LED: five flashes, “Flame out of sequence”, and six flashes of four, “System in lockout. Flame sense out of sequence.”; the fix for both is replacing the gas control (AP22511 Rev 02, p. 37).
  • Powered damper gas valve LED: six-four flashes, “System in Lockout/ Flame sense out of sequence”, caused by the gas control’s valve stuck open (AP15756, p. 25).
  • Six-LED panels: the pattern ● ○ ○ ○ ● ○, “Flame signal sensed out of proper sequence.”, fixed by replacing the gas control (AP17505-1, p. 35).
  • Maximus display: A012, “Flame Detected During Standby/Disabled Mode”; A027, flame current detected before the gas valve opens; A028, flame current detected 10 seconds after it closes (AP21833 Rev 02, pp. 42, 44).

Related codes: 6-4 flashes, 5 flashes, A028. All Rheem gas tank water heaters codes

Checked

Status light, gas valve LED or display

9 blinks

“Chamber Sensor Failure”

Technician

Printed on 11 model series · 5 documents

Rheem Professional Classic Series Ultra Low NOx Skinny Models, Ruud Professional Achiever Series Ultra Low NOx Skinny Models, Rheem PERFORMANCE Ultra Low NOx High BTU Models with Installed Side Water Connections, Rheem Professional Classic Series Ultra Low NOx High BTU Models with Installed Side Water Connections, Ruud Professional Achiever Series Ultra Low NOx High BTU with Side Connections Models, Rheem Performance Ultra Low NOx Skinny, Rheem Performance Series: Ultra Low NOx, Rheem Professional Classic Series: Heavy Duty Ultra Low NOx, Rheem Professional Classic Plus Series: Heavy Duty Ultra Low NOx, Ruud Professional Achiever Series: Heavy Duty Ultra Low NOx, Rheem Performance Series: High Demand Ultra Low NOx Atmospheric · AP23698 p. 24; AP22858 p. 23; AP23699 p. 24; AP19928 Rev 02 p. 24; AP20849 Rev 02 p. 24

Legend on the gas control label, as reproduced in the manual; printed in red.

Short answer Nine red blinks mean chamber sensor failure on models covered by five Ultra Low NOx status light manuals (two add "or bimetal switch activated"). Rheem's only step is to contact a qualified service technician. Other status light manuals do not list nine blinks. See what to check

Nine red blinks every three seconds is the label’s “Chamber Sensor Failure”. Only the Ultra Low NOx status light manuals print it, in two wordings, and both rows say “Contact a qualified service technician. See “IF YOU NEED SERVICE” on page 28”:

  • “Chamber sensor failure.” in AP23698, AP23699 and AP22858, the manuals for the Ultra Low NOx Skinny models, the Performance Ultra Low NOx line and the Ultra Low NOx High BTU models (AP23699, p. 24; AP22858, p. 23).
  • “Chamber sensor failure or bimetal switch activated.” in AP20849 Rev 02 and AP19928 Rev 02, the manuals for the High Demand Ultra Low NOx Atmospheric and the Heavy Duty Ultra Low NOx models (AP20849 Rev 02, p. 24; AP19928 Rev 02, p. 24).

The status light manuals AP23060 Rev 01, AP16801-2 (08/14) and AP17110-1 (01/15) have no nine-blink row, so for the Performance and Performance Plus Atmospheric and the other heaters covered by them, Rheem does not describe nine blinks (AP23060 Rev 01, p. 24).

The same five Ultra Low NOx manuals add ten blinks, “Chamber temperature shutdown.”, with the same remedy (AP23699, p. 24). None of them says where the chamber sensor is or what it measures.

The table gives the owner one step for nine blinks: contact a qualified service technician (AP23699, p. 24).

  1. If you smell gas, stop and follow the steps at the top of this page.
  2. Check which manual your heater has. Its AP number is on the cover, and the product pages on rheem.com, ruud.com and richmondwaterheaters.com link each model line to its manual. If your manual has no nine-blink row, this code is not defined for your heater.
  3. Read the code with the pilot lit. The NOTICE above the table in AP23698, AP23699 and AP22858 says the pilot burner must be lit to view status light codes (AP23699, p. 24).
  4. Have the model and serial number from the rating plate ready. Call your installer, plumbing contractor or service agency first; the manual lists Rheem’s Manufacturer’s National Service Department at 1-866-279-4566 as the next step (AP23699, p. 28).
  • For the code itself, in all five manuals that print it (AP23699, p. 24; AP19928 Rev 02, p. 24).
  • For any work behind the burner access door. The installation section of AP23699 says the burner chamber is designed to be sealed with a gasket and tamper resistant screws, that the burner access door should not be removed unless absolutely necessary and only by a qualified service technician, and that a new gasket must go on any door that has been removed (AP23699, p. 14).
  • For repairs to the gas control, burners or other safety devices, which the manual refers to qualified service personnel (AP23699, p. 25).
Indicator and manuals Nine Ten or nine-two
Status light: AP23698, AP23699, p. 24; AP22858, p. 23 “Chamber sensor failure.” Ten blinks: “Chamber temperature shutdown.”
Status light: AP20849 Rev 02, AP19928 Rev 02, p. 24 “Chamber sensor failure or bimetal switch activated.” Ten blinks: “Chamber temperature shutdown.”
Status light: AP23060 Rev 01, AP16801-2 (08/14), AP17110-1 (01/15), p. 24 No row No row
Powered damper gas valve LED, Ultra Low NOx: AP19336 (12/17), p. 26 Nine flashes: “Chamber Sensor Fault”; causes “Sensor Unplugged.” and “Sensor Fault”; fix “Replace Sensor” Nine-two flashes: “Chamber Temperature Fault”; cause “Insufficient supply air detected”; “Contact Authorized Service Provider”
Gas valve LED, AP19361 (12/17): p. 32 Nine flashes: “Chamber sensor fault”; fix “Replace sensor” Nine-two flashes: “Chamber temperature fault”; “Contact Authorized Service Provider”

The other powered damper manuals, AP15756 (05/10), AP15873 (06/10), AP16881-1 (03/17) and AP17115 (11/13), the power vent manuals AP22511 Rev 02, AP23058 Rev 01 and AP23057 Rev 01, and the induced draft manuals AP15696-3 (03/17) and AP15696 (11/10) have no nine-flash row. On the gas valve LED, the second code is nine-two flashes, not ten.

One overlap to watch: the rheem.com pages for the Performance Series: Ultra Low NOx link both AP23699, which has the nine-blink row, and AP17110-1 (01/15), which does not, and they do not say which manual goes with which model. Check the AP number on the manual that came with your heater.

Related codes: 10 blinks, 9 flashes, 9-2 flashes. All Rheem gas tank water heaters codes

Rheem power vent water heater 3 flashes: pressure switch open

Checked

Status light, gas valve LED or display

3 flashes

“Pressure and/or blower thermal switch failed open.”

Technician

Printed on 7 model series · 4 documents

Rheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page) · AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP22524 Rev 02 p. 37

Printed as: Three flashes every three seconds; display code 46.

Short answer On Rheem power vent and induced draft tanks, three gas valve LED flashes mean a pressure switch failed open; on powered damper tanks, the flue damper switch is open. Fixes are technician work; power vent owners can check the outdoor vent terminal. See what to check

What it means

Three flashes is the code for a switch that failed open. On power vent models, the control checks the blower vacuum switch at start-up and on each call for heat: it verifies that the switch is open, runs the blower for a pre-purge of about 5 seconds, and then verifies that the switch has closed, “ensuring that the blower is functioning properly and that the venting system is not blocked” (AP22511 Rev 02, p. 31). Which switch the code names depends on the manual:

  • Power vent: “Pressure and/or blower thermal switch failed open.”, LCD code 46 on models with the optional display. The table’s fixes: verify that the wiring to the blower pressure switch and thermal switch is correct and properly connected, check the vent system for blockage or obstructions, and replace the blower assembly (AP22511 Rev 02, p. 37).
  • Induced draft, and the Ruud Ultra Low NOx manual AP19361 (12/17): “Pressure switch failed open.” Its causes are “Vent blockage or improper installation, switch tube blockage, faulty switch, blower improper operation or temperature switch open” (AP15696-3, p. 28; AP19361, p. 32).
  • Powered damper: “System in Lockout/Flue Damper Switch open”. Its causes include an improperly installed damper, a damper switch stuck open or faulty, incorrect wiring, a faulty damper motor, and obstruction or debris in the damper opening (AP15756, p. 24).

Check these first

The power vent manual gives the owner part of the vent check as routine maintenance:

  1. If you smell gas, stop and follow the steps at the top of this page.
  2. Check the outdoor vent terminal “to see that it is free of obstructions, and that there is no damage nearby caused by condensate” (AP22511 Rev 02, p. 32). In applicable climates, the manual also says to inspect the vent and air-inlet terminals for snow (AP22511 Rev 02, p. 33).
  3. Inspect the dilution air inlet and the combustion air inlet openings, make certain no blockage exists, and clean any lint, dirt or oil accumulation; clean the screens in the vent terminal if it has them (AP22511 Rev 02, p. 32).
  4. If the vent may be blocked beyond what you can see, the manual’s chart says to “Contact a qualified service technician to evaluate vent system for blockage.” (AP22511 Rev 02, p. 35).

In the powered damper and induced draft manuals, the three-flash rows list only technician fixes; the powered damper row ends with “Contact a qualified service technician.” (AP15756, p. 24).

When to call a licensed technician

  • Wiring to the pressure switch, thermal switch or flue damper switch, the switch tube, and the switches themselves (AP22511 Rev 02, p. 37; AP15696-3, p. 28; AP15756, p. 24).
  • Replacing the blower assembly or the blower temperature switch (AP22511 Rev 02, p. 37; AP15696-3, p. 28), or the flue damper assembly (AP15756, p. 24).
  • Evaluating the vent system for blockage or improper installation (AP22511 Rev 02, p. 35).

The power vent table sits under cautions about servicing controls and not attempting repair of the vent system or other safety devices (AP22511 Rev 02, p. 37).

Notes for different models

Indicator and manuals Three Six-two code for the same switch
Power vent: AP22511 Rev 02, AP23058 Rev 01, AP23057 Rev 01, p. 37 “Pressure and/or blower thermal switch failed open.” (LCD 46) Six flashes of two: “System in lockout. Blower pressure switch and/or thermal switch open.” (LCD 45)
Induced draft: AP15696-3 (03/17), AP15696 (11/10), p. 28. Also the Ruud manual AP19361 (12/17), p. 32 “Pressure switch failed open.” Six-two: “Recycle limit - PS/limit opened”, with excessive wind at the vent termination added to the causes
Powered damper: AP15756 (05/10), AP15873 (06/10), AP17115 (11/13), p. 24 “System in Lockout/Flue Damper Switch open” Six-two: “System in Lockout/ Flue Damper Switch opened”

The power vent table calls its six-two code a lockout; the manuals do not say how many three-flash events lead to it.

On the six-LED panels of some power vent and power direct vent models, the open pressure switch is the pattern ● ○ ● ○ ○ ●, “Pressure switch remained open longer than 5 seconds after the combustion blower was energized.”, and the fixes include checking for an obstructed air intake or exhaust (AP17505-1, p. 35). On the Maximus display, A003 and A007 are the intake and exhaust pressure switches found open, with “Check switch wiring and venting.” (AP21833 Rev 02, p. 42).

The blue and red status light has no three-blink code (AP23060 Rev 01, p. 24).

Related codes: 6-2 flashes, 2 flashes, ● ○ ● ○ ○ ●. All Rheem gas tank water heaters codes

Rheem power vent water heater 6-1 flashes: failed to light

Checked

Status light, gas valve LED or display

6-1 flashes

“System in lockout. Failed trial for ignitions.”

Technician

Printed on 7 model series · 4 documents

Rheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent, AP22524 Rev 02 (manual not listed on a product page) · AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37; AP22524 Rev 02 p. 37

Printed as: Six flashes of one, every three seconds; display code 11.

Short answer On Rheem power vent, induced draft and powered damper tanks, six flashes of one mean the heater failed to light. The tables name gas supply problems and the pilot; pilot and gas control work is for a technician. See what to check

What it means

The manuals print this gas valve LED code as “Six flashes of one, every three seconds” (power vent) and as “Six-One Flash” or “Six-One Flashes” with a three-second pause (induced draft and powered damper) (AP22511 Rev 02, p. 37; AP15696-3, p. 28; AP15756, p. 24).

On power vent models the pilot is lit by a spark, and the main gas valve opens only once the pilot flame is established (AP22511 Rev 02, p. 31). The manual adds: “If no main burner flame is established, the gas control will go through three trials for ignition before going into a lock-out. A warning light will alert the user of this lock-out condition.” It then sends you to its troubleshooting guide (AP22511 Rev 02, p. 29). The wording of the code:

  • Power vent: “System in lockout. Failed trial for ignitions.”, LCD code 11 on models with the optional display. The table’s fixes, in order: the gas supply is off or too low to operate, so turn on the gas supply and/or increase the inlet gas supply pressure; replace the pilot assembly; replace the combination gas control (thermostat) (AP22511 Rev 02, p. 37).
  • Induced draft, and the Ruud Ultra Low NOx manual AP19361 (12/17): “Failed trial for ignition”, caused by “Insufficient gas supply, unstable pilot, carbon buildup on electrode or wire/pilot tube damage”; fixes “Check gas supply” and “Replace pilot” (AP15696-3, p. 28; AP19361, p. 32).
  • Powered damper: “System in Lockout/ Unit failed to light”. Its causes are an unstable pilot flame, a restricted or damaged pilot tube, carbon build-up on the pilot’s electrode, a damaged pilot igniter wire and gas supply problems; fixes “Replace Pilot assembly” and “Correct gas supply” (AP15756, p. 24).

Check these first

  1. If you smell gas, stop and follow the steps at the top of this page.
  2. Make sure the gas supply to the heater is on. The power vent table’s first fix is “Gas supply is off or too low to operate. Turn on the gas supply and/or increase the inlet gas supply pressure.” (AP22511 Rev 02, p. 37). Raising the inlet gas supply pressure is not an owner step.
  3. The owner’s operating procedure is the label on the heater. The power vent label’s steps use the ON/OFF switch on the gas control, the electric power and a five-minute wait to clear out any gas, and it says not to light the pilot by hand. “If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” and call your service technician or gas supplier.” (AP22511 Rev 02, p. 28). The powered damper label ends the same way (AP15756, p. 17).

When to call a licensed technician

  • When the heater does not operate after the label’s steps (AP22511 Rev 02, p. 28).
  • For low inlet gas pressure, the pilot assembly, the pilot tube and electrode, the igniter wire, and the gas control (AP22511 Rev 02, p. 37; AP15696-3, p. 28; AP15756, p. 24).
  • For air in the gas line. The power vent chart sends “Unable to light the main burner” with air in the gas line to “a qualified service technician to purge the air from the gas line.” (AP22511 Rev 02, p. 35).

The power vent table sits under the caution not to attempt repair of gas piping, the gas control, burners, the vent system or other safety devices (AP22511 Rev 02, p. 37).

Notes for different models

Indicator and manuals Six-one Related ignition codes
Power vent: AP22511 Rev 02, AP23058 Rev 01, AP23057 Rev 01, p. 37 “System in lockout. Failed trial for ignitions.” (LCD 11) Six flashes of five: “System in lockout. Failed Ignition attempts.” (LCD 10), same fixes; six flashes of three: “System in lockout. Flame lost.” (LCD 13)
Induced draft: AP15696-3 (03/17), AP15696 (11/10), p. 28. Also the Ruud manual AP19361 (12/17), p. 32 “Failed trial for ignition” Six-three: “Recycle limit - flame lost”
Powered damper: AP15756 (05/10), AP15873 (06/10), AP17115 (11/13), p. 24 “System in Lockout/ Unit failed to light” Six-three: “System in Lockout/ Flame Lost”

On the six-LED panels of some power vent and power direct vent models, the lockout row is the pattern ● ○ ○ ● ● ○, “System in lockout.”, and its first fix is “Gas supply is off or too low to operate.” (AP17505-1, p. 35). On the Maximus, A001 is an ignition lockout after 9 consecutive failed ignitions and T029 is “Unit did not light.” (AP21833 Rev 02, pp. 42, 44); see A001.

The LCD codes 10 to 15 on a power vent tank are not the tankless codes with the same numbers; numbered tankless codes are in the Rheem tankless table.

Related codes: 6-5 flashes, 6-3 flashes, 1 flash. All Rheem gas tank water heaters codes

Rheem power vent water heater 7 flashes: flammable vapor lockout

Checked

Status light, gas valve LED or display

7 flashes

“System in lockout. Flammable vapor sensor.”

Technician

Printed on 6 model series · 3 documents

Rheem Professional Classic Plus Series: Heavy Duty Power Vent, Rheem Professional Classic Series: Power Vent Ultra Low NOx, Rheem Professional Classic Series: Power Vent, Rheem Performance Series: Power Vent, Richmond Essential Series: Power Vent, Ruud Professional Achiever Series: Power Vent · AP22511 Rev 02 p. 37; AP23058 Rev 01 p. 37; AP23057 Rev 01 p. 37

Printed as: Seven flashes every three seconds; display code 47.

Short answer On Rheem, Ruud and Richmond power vent, powered damper and induced draft tanks, seven gas valve LED flashes mean a flammable vapor sensor lockout. The manuals tell the owner to promptly contact a qualified service technician. Status light models use seven blinks differently. See what to check

What it means

These tanks have a flammable vapor sensor that the electronic control watches in all modes of operation. When it detects flammable vapors, the control shuts the heater down and keeps it from being started again (AP22511 Rev 02, p. 31). Seven flashes of the gas valve LED is that lockout. The wording differs by manual:

  • Power vent: “System in lockout. Flammable vapor sensor.”, shown as LCD code 47 on models with the optional display (AP22511 Rev 02, p. 37).
  • Powered damper: “System in Lockout/ Presence of Flammable Vapors detected”. The table’s causes are gasoline or other flammable vapors, a faulty flammable vapor sensor or a faulty gas control (thermostat) (AP15756, p. 25).
  • Induced draft, and the Ruud Ultra Low NOx manual AP19361 (12/17): “Flammable vapor sensor lockout”, caused by “Gasoline or other flammable gas was detected near the appliance or the sensor has failed” (AP15696, p. 28; AP19361, p. 32).

The power vent manual lists what sets the sensor off: vapors of gasoline; vapors of certain flammable paints, stains and thinners; vapors of vent pipe cement and solvents; bleach in direct contact with the sensor; and some other flammable materials and their vapors (AP22511 Rev 02, p. 31).

The powered damper manual explains why the heater stays off. Air movement can carry flammable vapors some distance, and the pilot or main burner can ignite them and “create a shut down condition of the water heater which will not allow the water heater to ignite until examined by a Qualified Service Technician” (AP15756, p. 7).

Check these first

The power vent manual gives the owner this instruction: “If the flammable vapor sensor shuts down the water heater, then the electronic control will display the appropriate error code and you should then promptly contact a qualified service technician.” (AP22511 Rev 02, p. 31). Page 3 of the power vent and induced draft manuals adds three things: clear any hazardous materials and ventilate the area around the water heater; do not turn off the appliance or adjust the ON/OFF switch in any way; do not tamper with the flammable vapor sensor (AP22511 Rev 02, p. 3; AP15696 (11/10), p. 3; AP15696-3, p. 3; AP19361, p. 3). What else they say:

  1. If you smell gas, stop and follow the steps at the top of this page.
  2. Contact a qualified service technician. Page 3 of the power vent and induced draft manuals says it too: “If the flammable vapor sensor shuts down the water heater, contact a qualified service technician.” (AP22511 Rev 02, p. 3; AP15696, p. 3; AP19361, p. 3). The powered damper manual says the same about its combustion shut off device (AP15756, p. 20).
  3. Do not store or use gasoline or other flammable vapors and liquids, such as adhesives or paint thinner, near the heater. If such flammables must be used, the manual says to open doors and windows for ventilation and to shut off all gas burning appliances nearby, including their pilot burners (AP22511 Rev 02, p. 29).
  4. Do not block the flammable vapor sensor, and keep water, solvents and cleaning agents off it. The manual says it needs no maintenance or cleaning (AP22511 Rev 02, p. 33).

When to call a licensed technician

  • For every seven-flash lockout, as above (AP22511 Rev 02, p. 31).
  • The gas valve LED table sits under cautions about servicing controls and not attempting repair of the gas control. For power vent models it lists three steps: verify that no gasoline or flammable vapors are present, reset the combination gas control (thermostat), and replace the flammable vapor sensor (AP22511 Rev 02, p. 37). The powered damper table resets the gas control with the “ON/OFF” switch on its front and adds replacing the gas control (AP15756, p. 25). The owner’s sections of the same manuals do not hand the reset to the owner; they send the shutdown to a technician.
  • 8-1 flashes is a different code, a fault in the sensor itself: “Flammable vapor sensor, fault detected.” on power vent models, fixed by replacing the sensor or the gas control (AP22511 Rev 02, p. 37).

Notes for different models

Indicator and manuals What seven flashes mean
Power vent: AP22511 Rev 02, AP23058 Rev 01, AP23057 Rev 01, p. 37 “System in lockout. Flammable vapor sensor.” (LCD code 47)
Powered damper: AP15756 (05/10), AP15873 (06/10), AP17115 (11/13), p. 25; AP16881-1 (03/17), AP19336 (12/17), p. 26 “System in Lockout/ Presence of Flammable Vapors detected”
Induced draft: AP15696-3 (03/17), p. 28 “Flammable vapour sensor lockout”
Induced draft: AP15696 (11/10), p. 28. Also the Ruud manual AP19361 (12/17), p. 32 “Flammable vapor sensor lockout”

On the six-LED panels of some power vent and power direct vent models, the same lockout is the pattern ● ○ ○ ○ ○ ●, “Unit shuts down and in lockout.”, with “1. FV sensor detected presence of flammable vapors. 2. Contact a service agency.” (AP17505-1, p. 35; AP14896-2, p. 39). The pattern ● ○ ○ ● ○ ●, “Unit shuts down.”, lists the sensor’s wiring, open circuits to the sensor and replacing the sensor as its fixes (AP17505-1, p. 35).

On models with the blue and red status light, seven red blinks mean “Combination Gas Control failure” instead; see 7 blinks. Those manuals describe a combustion shut off device that shuts the heater down if undesirable combustion conditions occur, such as flammable vapors or blocked combustion air inlet openings, and say to contact a qualified service technician if this occurs (AP23060 Rev 01, p. 22).

Related codes: 8-1 flashes, ● ○ ○ ○ ○ ●, ● ○ ○ ● ○ ●. All Rheem gas tank water heaters codes

Rheem Maximus A001: ignition lockout, what to check

Checked

Status light, gas valve LED or display

A001

“Ignition lockout due to a total of 9 consecutive failed ignitions. This will disable the heater.”

Owner checks, then technician

Printed on 11 model series · 4 documents

Rheem Professional Prestige Maximus Heavy Duty with LeakSense, Rheem Performance Platinum Maximus With LeakSense, Rheem Performance Platinum Maximus Heavy Duty With LeakSense, Ruud Professional Ultra Super High Efficiency Gas Heavy Duty with LeakSense, Rheem Professional Classic Plus Maximus, Rheem Performance Plus Maximus, Ruud Professional Achiever Plus Super High Efficiency Gas, Rheem Professional Prestige Maximus with LeakSense, Ruud Professional Ultra Super High Efficiency Gas Water Heater with LeakSense, Richmond Encore Super High Efficiency Gas Water Heater With Leaksense, AP23008 Rev 03 (manual not listed on a product page) · AP23779 p. 42; AP21833 Rev 02 p. 42; AP21831 Rev 02 p. 42; AP23008 Rev 03 p. 35

Short answer A001 is an ignition lockout on Rheem, Ruud and Richmond super high efficiency tanks: 9 failed ignitions in the use and care manuals, 27 in the service manual. Turn the unit off and on; if it persists, contact technical support or a service provider. See what to check

What it means

A001 is an alarm. Rheem’s table describes it as “Ignition lockout due to a total of 9 consecutive failed ignitions. This will disable the heater.” The alarm screen reads “A001 Ignition lockout.” with the instruction “Clear error code by turning the unit off/on. If problem persists, contact technical support or service provider.” (AP21833 Rev 02, p. 42). AP21831 Rev 02 and AP23779 print the same row on p. 42, and the service manual AP23008 Rev 03 on p. 35.

The service manual describes a longer sequence than the 9 in its own code table: after 9 failed ignition attempts the control shows alert T029 and waits 30 minutes; after two more rounds of 9, 27 consecutive failed attempts in all, it shows A001 and stays locked out until the power is cycled (AP23008 Rev 03, pp. 31, 32, 47). The use and care manuals give only the count of 9.

The table’s other codes help place it. T029, an alert, is “Unit did not light.” and its screen reads “T029 Failed ignition. Retrying.” (AP21833 Rev 02, p. 44). A001 is the alarm that disables the heater (AP21833 Rev 02, p. 42). T029 is the alert shown while the control is still retrying.

You find the code on the touchscreen. With an active alarm the “Service” button blinks on the home screen; pressing it shows the active alarms and the alarm history, and “more info” gives a longer explanation (AP21833 Rev 02, pp. 37–38).

Check these first

  1. If you smell gas, stop and follow the steps at the top of this page.
  2. Clear the code by turning the unit off and on, as the alarm screen says (AP21833 Rev 02, p. 42). The manual’s chart refers to the unit’s “ON/OFF” switch (AP21833 Rev 02, p. 41).
  3. If the burner still will not light, the chart’s first row is air in the gas line: “Let the unit cycle at least 3 times to remove air from the gas line. If the unit does not try to light, contact a qualified service technician to purge the air from the gas line.” (AP21833 Rev 02, p. 40).
  4. The next row is the gas valves: “Check to make sure that all manual shut-off valves between the unit and the gas line are open.” (AP21833 Rev 02, p. 40).
  5. If A001 persists, contact technical support or a service provider, as the screen says (AP21833 Rev 02, p. 42).

When to call a licensed technician

  • A001 that comes back after the off and on (AP21833 Rev 02, p. 42).
  • The other causes in the chart for a main burner that will not light: a blocked inlet or exhaust vent pipe, the pressure switch and its hoses, wire connections that are not fully secured, and a gas control problem (AP21833 Rev 02, pp. 40–41). Apart from making sure the pressure switch hoses are not kinked or disconnected, these are checks for a qualified service technician.
  • Grounding. The chart says to verify that the electrical supply line and the unit have a proper ground connection (AP21833 Rev 02, p. 41).
  • Anything behind the protective cover. The manual says to make certain power to the water heater is off before removing it for any reason, and not to attempt repair of gas piping, the gas control, the burner, vent connectors or other safety devices (AP21833 Rev 02, p. 41).

Notes for different models

Rheem’s product pages link three use and care manuals with the same A001 row:

Manual Cover Linked from
AP21833 Rev 02, p. 42 “RESIDENTIAL HIGH EFFICIENCY WATER HEATER” Professional Classic Plus Maximus, Performance Plus Maximus
AP21831 Rev 02, p. 42 “RESIDENTIAL SUPER HIGH EFFICIENCY WATER HEATER” Professional Prestige Maximus with LeakSense; Ruud Professional Achiever Plus and Professional Ultra Super High Efficiency Gas; Richmond Encore Super High Efficiency Gas
AP23779, p. 42 “COMMERCIAL HIGH EFFICIENCY WATER HEATER” Performance Platinum Maximus with LeakSense, its Heavy Duty version, Professional Prestige Maximus Heavy Duty with LeakSense; Ruud Professional Ultra Super High Efficiency Gas Heavy Duty

AP23779 says “commercial” on the cover but is the manual rheem.com links for these residential pages. Its text differs from AP21833 in 22 of the 58 rows, but not in A001. The service manual AP23008 Rev 03 lists 80 codes, including some that the use and care manuals do not print (AP23008 Rev 03, pp. 35–42).

A002, “Flame not stable lockout. Lost flame three times during one heat cycle.”, carries the same off-and-on instruction (AP21833 Rev 02, p. 42).

The status light and gas valve LED models have no A codes. On power vent models the comparable lockout is 6-1 flashes.

Related codes: A002, T029, A030. All Rheem gas tank water heaters codes

How to read the status light

Rheem gas tanks use four kinds of indicators, and one count can mean different things on each. Seven is “Combination Gas Control failure” on the status light (AP23060 Rev 01, p. 24) and “System in lockout. Flammable vapor sensor.” on the power vent gas valve LED (AP22511 Rev 02, p. 37). Find your indicator first:

  • A status light on the gas control that blinks blue or red. One blue blink every three seconds is “Normal Operation”; red counts of 2, 4, 5, 7 and 8 are faults; five Ultra Low NOx manuals (AP23698, AP23699, AP22858, AP20849 Rev 02, AP19928 Rev 02) add 9 and 10, and the Ultra Low NOx manual AP17110-1 (01/15) has neither (AP23060 Rev 01, p. 24; AP23699, p. 24; AP17110-1, p. 24). The pilot must be lit before the light can show a code (AP23060 Rev 01, p. 24).
  • A gas valve LED on power vent, powered damper and induced draft models. A short flash every four seconds and a bright/dim “heartbeat” are normal states; some fault codes have two numbers, printed as “Six-One Flashes” (AP15756, p. 24). Power vent models with the optional display also show an LCD code number (AP22511 Rev 02, p. 37).
  • A row of six LEDs on some power vent and power direct vent models. It normally shows the temperature setting; a fault is a pattern, listed in the table above as ● for a lit LED and ○ for an unlit one (AP17505-1, pp. 28, 35).
  • A touchscreen with A (alarm) and T (alert) codes on the Maximus and other super high efficiency models (AP21833 Rev 02, p. 42).

The manuals for the Professional Classic and Classic Plus Atmospheric, the Professional Classic Plus Heavy Duty, the Professional Classic and Classic Plus Ultra Low NOx (not the Skinny, High BTU or Heavy Duty Ultra Low NOx models), the Direct Vent lines and the manufactured housing lines have no indicator table, only a “Before You Call For Service” chart (AP22543 Rev 04, pp. 21–22; AP23059 Rev 01, pp. 22–23).

A manual’s cover gives its AP number, not the series. The product pages on rheem.com, ruud.com and richmondwaterheaters.com link each line to its manual. Most AP files are posted on all three sites; AP16412-2, AP17505-1, AP23057, AP15696 (11/10), AP15762 and AP19361 appear only on Ruud and Richmond pages.

Clearing a code

The status light manuals have no reset button and no reset procedure. Their table offers these remedies: turn the gas control on or light the pilot when the light is off or constantly lit; set the temperature knob for one blink; for two blinks or low millivoltage, a check of the thermopile connector, the thermopile wires and the pilot assembly (technician work); and “Contact a qualified service technician” for red codes 4, 5, 7 and 8 (AP23060 Rev 01, p. 24).

In the power vent, powered damper and induced draft manuals, a reset appears only in the solution column of the gas valve LED table, such as “Reset the Gas Control (Thermostat) using “ON/OFF” switch located on the front of the control” (AP15756, p. 25). For a flammable vapor shutdown, the owner’s section says to contact a qualified service technician (AP22511 Rev 02, p. 31).

On the Maximus, the A001 and A002 screens say “Clear error code by turning the unit off/on” and “If problem persists, contact technical support or service provider.” (AP21833 Rev 02, p. 42).

Lighting the pilot

Follow the label on your own heater; the manual reprints it under “Lighting the water heater”.

  • Status light models: hold the knob in at PILOT and press the piezo button until the STATUS light begins to blink, then check the pilot through the sight glass. No blinking after 90 seconds and no pilot means repeating steps 2 through 6; a knob that does not pop back out means stop and call your service technician or gas supplier (AP23060 Rev 01, p. 17).
  • Professional Classic Atmospheric: a separate thermostat dial goes to “PILOT LIGHTING”, and you hold the knob down for about one minute after the pilot lights (AP22543 Rev 04, p. 16).
  • Power vent and powered damper models light the pilot automatically; their labels say not to light it by hand and use the ON/OFF switch, the electric power and a five-minute wait (AP22511 Rev 02, p. 28; AP15756, p. 17).

Tank or tankless?

Numbers such as 11, 12, 29 or 99 are also Rheem tankless codes, listed in the Rheem tankless code table. A power vent tank with the optional display prints LCD codes 10 to 15, 31, 44 to 47, 49, 89 and 93 next to the LED flashes (AP22511 Rev 02, p. 37); there 11 is “System in lockout. Failed trial for ignitions.” and 12 is “Low flame signal”. The tank manuals here do not print 17 or 99, and 29 appears only as T029 on the Maximus display (AP21833 Rev 02, p. 44). Tank manuals give capacities in gallons, for example “For 29, 30, 40, 50, 55 and 60 gallon models” (AP23060 Rev 01, p. 25).

If you are replacing a tank, the water heater size calculator estimates the first-hour rating you need. Gas tanks made from May 6, 2029 must meet the formula in DOE’s new rule; see the 2029 DOE water heater standard.

Which gas control is on your heater

  • Status light manuals call the part “Combination Gas Control (Thermostat)” and name no maker (AP23060 Rev 01, p. 24).
  • Power vent manuals label the valve “HONEYWELL ELECTRONIC CONTROL” in the wiring diagram, with no model number (AP22511 Rev 02, p. 23), and the photo on the powered damper label in AP15756 (05/10) shows a gas control marked Honeywell (AP15756, p. 17).
  • The Maximus service manual names Fasco and SIT valves (AP23008 Rev 03, pp. 15, 48).
  • For older heaters, Rheem’s bulletins name White Rodgers controls on standard 30, 40, 50 and 60 gallon atmospheric models from September 3, 2007 (TB 1425, p. 1) and on the Guardian PowerVent from October 2007 (TB 1621, p. 1).

This site reads codes from Rheem’s tables only, not from a valve maker’s flash chart.

When to stop and call a professional

  • You smell gas or suspect a leak. The manual says not to look for the cause yourself, to leave the house with your family and pets, and to stay away until a qualified agency has found the area safe (AP23060 Rev 01, p. 5).
  • Red status code 4, 5, 7, 8, 9 or 10 (AP23060 Rev 01, p. 24; AP23699, p. 24), or a flammable vapor or combustion shutoff (AP22511 Rev 02, p. 31; AP23060 Rev 01, p. 20).
  • A knob that does not pop back out, or a pilot that will not stay lit after several tries (AP23060 Rev 01, p. 17).
  • Overheating, fire, flood, physical damage, or gas that does not shut off: turn off the manual gas shut-off valve (AP23060 Rev 01, p. 18). A flooded heater must be replaced (AP23060 Rev 01, p. 17).
  • Any repair of gas piping, the gas control, burners, vent connectors or other safety devices (AP23060 Rev 01, p. 22). Thermopile and pilot work, gas pressure and the temperature limits are jobs for a licensed technician.

Rheem’s order for service is your installer, plumbing contractor or service agency first, then its Manufacturer’s National Service Department at 1-866-279-4566; have the model and serial number from the rating plate ready (AP23060 Rev 01, p. 28).

See also

Rheem, Ruud, Richmond are trademarks of their owners. How House Works is not affiliated with or endorsed by Rheem, Ruud, Richmond.

Sources

35 documents
  1. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP23060 Rev 01. Accessed Oct 26, 2026.
  2. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP22543 Rev 04. Accessed Oct 26, 2026.
  3. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP23059 Rev 01. Accessed Oct 26, 2026.
  4. Rheem Manufacturing Company. Technical Bulletin 1425 – White Rodger Thermostat Control Atmospheric Gas Water Heater. TB 1425, September 3, 2007. File linked from Rheem's Water Heating Technical Bulletins index (rheem.com/whtechbulletins/). Accessed Oct 26, 2026.
  5. Rheem Manufacturing Company. Technical Bulletin 1621 – White Rodgers Intelli-VentTM Guardian PowerVent Control. TB 1621, no date printed. File linked from Rheem's Water Heating Technical Bulletins index (rheem.com/whtechbulletins/). Accessed Oct 26, 2026.
  6. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - Low NOx Emissions. AP23698. Accessed Oct 26, 2026.
  7. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP22858. Accessed Oct 26, 2026.
  8. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - Low NOx Emissions. AP23699. Accessed Oct 26, 2026.
  9. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - Ultra Low NOx Emissions. AP19928 Rev 02. Accessed Oct 26, 2026.
  10. Rheem Manufacturing Company. Residential 29, 30, 40, 50, 55 and 60 Gallon with Electronic Control, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters. AP16801-2 (08/14). Accessed Oct 26, 2026.
  11. Rheem Manufacturing Company. Residential 28, 38, 40, 48 and 55 Gallon, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters. AP17110-1 (01/15). Accessed Oct 26, 2026.
  12. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - Ultra Low NOx Emissions. AP20849 Rev 02. Accessed Oct 26, 2026.
  13. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Induced Draft, Residential Gas - FVIR Certified. AP15696-3 (03/17). Accessed Oct 26, 2026.
  14. Rheem Manufacturing Company. Residential 29 Gallon, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Induced Draft, Residential Gas - FVIR Certified. AP15696 (11/10). Accessed Oct 26, 2026.
  15. Rheem Manufacturing Company. Water Heaters, Residential Gas - Low NOx Emissions, FVIR Certified, Use & Care Manual. AP19361 (12/17). Accessed Oct 26, 2026.
  16. Rheem Manufacturing Company. Residential 38, 40, and 50 Gallon, Residential Gas - FVIR Certified, With Damper & Electronic Control. AP15756 (05/10). Accessed Oct 26, 2026.
  17. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - Low NOx Emissions. AP19336 (12/17). Accessed Oct 26, 2026.
  18. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP16881-1 (03/17). Accessed Oct 26, 2026.
  19. Rheem Manufacturing Company. Residential 38 and 48 Gallon, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters. AP15873 (06/10). Accessed Oct 26, 2026.
  20. Rheem Manufacturing Company. Residential 38, 40 and 50 Gallon, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters. AP17115 (11/13). Accessed Oct 26, 2026.
  21. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP22511 Rev 02. Accessed Oct 26, 2026.
  22. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP23058 Rev 01. Accessed Oct 26, 2026.
  23. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP23057 Rev 01. Accessed Oct 26, 2026.
  24. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP22524 Rev 02. Accessed Oct 26, 2026.
  25. Rheem Manufacturing Company. Residential 40, 50, 65 & 75 Gallon Models, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters. AP14896-2 (12/10). Accessed Oct 26, 2026.
  26. Rheem Manufacturing Company. Residential 40, 50, 65 & 75 Gallon Models, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters. AP14896-3 (06/11). Accessed Oct 26, 2026.
  27. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Gas Water Heaters, FVIR Compliant. AP17505-1 (03/17). Accessed Oct 26, 2026.
  28. Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Gas Water Heaters, Low NOx Emissions. AP16412-2. Accessed Oct 26, 2026.
  29. Rheem Manufacturing Company. Residential 60 And 75 Gallon, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters. AP15762 (04/10). Accessed Oct 26, 2026.
  30. Rheem Manufacturing Company. Residential 75 Gallon, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters. AP22670. Accessed Oct 26, 2026.
  31. Rheem Manufacturing Company. Residential 40, 50, 65 & 75 Gallon Models, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified, PowerDirect Vent (Canada, bilingual). AP22539 Rev 01. Canadian market manual (listed on rheem.com as "Canada"). Accessed Oct 26, 2026.
  32. Rheem Manufacturing Company. COMMERCIAL HIGH EFFICIENCY WATER HEATER, USE & CARE MANUAL. AP23779. Accessed Oct 26, 2026.
  33. Rheem Manufacturing Company. RESIDENTIAL HIGH EFFICIENCY WATER HEATER, USE & CARE MANUAL. AP21833 Rev 02. Accessed Oct 26, 2026.
  34. Rheem Manufacturing Company. RESIDENTIAL SUPER HIGH EFFICIENCY WATER HEATER, USE & CARE MANUAL. AP21831 Rev 02. Accessed Oct 26, 2026.
  35. Rheem Manufacturing Company. 40, 50, and 75 Gallon Service Manual, Residential and Commercial, Condensing Water Heater (includes Maximus and Triton LD). AP23008 Rev 03. Accessed Oct 26, 2026.