Rheem tankless water heater error codes

116 codes for RTGH-3, RTG-3, RTG-R-3, IKONIC, ThermaForce, Ruud Mid-Efficiency, each with the wording and page from Rheem's manuals.

How House Works EditorialChecked against 16 sources,
How it is checked
Methodology
Page
HHW · ERROR-CODES · RHEEM
Based on
Rheem manuals

Meanings are quoted from Rheem's manuals. The "Who" column is our reading of the manual's remedy: whether an owner can do the first checks, or the fix belongs to a licensed technician.

Codes with step-by-step checks

  • P1Not enough water flow
  • 11Flame not detected
  • 12Flame lost
  • 14Overheat limiter
  • 29Condensate not draining
  • 61Blower motor
  • 90Blocked vent or air intake
  • 99Vent blockage after shutdown

How it works: How a tankless water heater lights: ignition codes by brand

All Rheem codes

CodeManual meaningWhoSeriesSource
1L“Water heater has buildup of lime deposits.”
The RTG-R-3 chart adds "Flushing the water heater is recommended." (RTG-R-3 manual, p. 74). The troubleshooting manual calls 1L a warning code, "Lime build-up detected in heat exchanger", and says the unit must be drained and flushed (AP21822 tech manual, p. 34).
TechnicianRTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency
6 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 34; AP24838 tech manual p. 27; AP18000-2 manual p. 26
P1“Not enough water flow to operate the unit.”
What to check
The RTG-R-3 chart adds "Water flow was low during recirculation cycle." and asks you to confirm there is no debris in the inlet water filter (RTG-R-3 manual, p. 74). The troubleshooting manual gives 0.4 GPM as the minimum flow to activate the heater (AP21822 tech manual, p. 34).
Owner can checkRTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency
6 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 34; AP24838 tech manual p. 27; AP18000-2 manual p. 26
03“Manifold setting failure”
Listed only in Rheem's troubleshooting manual for service professionals. Only for manifolded (multiple-unit) installations (AP21822 tech manual, p. 35).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 35; AP24838 tech manual p. 28
05“Low heat exchanger temperature detected”
Listed only in Rheem's troubleshooting manuals for service professionals: 05 is a warning, and if the low temperature continues the heater shows error 28 (AP21822 tech manual, p. 35). Ruud Tankless Mid-Efficiency heaters use 05 for something else. Their chart reads "Air intake or vent exhaust opening may be blocked." (remedy: "Remove any blockage.") and "The vent pipes on the vent termination may not be connected properly." (remedy: contact a dealer or qualified service technician) (AP18000-2 manual, p. 26).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 35; AP24838 tech manual p. 28
07“Limited hot water condition”
Listed only in Rheem's troubleshooting manual for service professionals. A warning shown only when a Wi-Fi controller is used, when the heater is set to water saving mode and controls the flow rate (AP21822 tech manual, p. 63).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 63; AP24838 tech manual p. 58
10“Incorrect inlet air volume”
Listed only in Rheem's troubleshooting manual for service professionals. A warning: the heater ran before the vent was installed, or the blower is not creating enough ventilation (AP21822 tech manual, p. 37). The same manual names 10 a "hard lockout" whose reset starts with removing the front cover (AP21822 tech manual, p. 61).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 37; AP24838 tech manual p. 30
11“The gas shut-off valve is not fully opened.”
What to check
Troubleshooting manual name: "Flame Not Detected by Flame Rod". The heater attempts ignition 2 times before it shows 11 (AP21822 tech manual, p. 37).
Owner checks, then technicianRTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency
6 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 37; AP24838 tech manual p. 30; AP18000-2 manual p. 26
12“Gas service has been interrupted.”
What to check
Second row in the same charts: "LP gas is running low (LP models only)." Troubleshooting manual name: "Detected Presence of Flame, Then Lost it", shown after the flame is lost 3 times in a row (AP21822 tech manual, p. 40). The EZ installation guides give "Check gas supply." as the first remedy, and the RTGH guide adds a DIP switch row (RTGH EZ guide, p. 7; RTG EZ guide, p. 2; RTG-R EZ guide, p. 2).
Owner checks, then technicianRTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency
6 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 40; AP24838 tech manual p. 33; AP18000-2 manual p. 26
13“If this code is still displayed after taking the numbered steps above.”
Only the Ruud Tankless Mid-Efficiency chart lists 13 (AP18000-2 manual, p. 26); the RTGH-3, RTG-3 and RTG-R-3 charts do not. Rheem's troubleshooting manuals name 13 only in the heading of a reset procedure for "hard lockouts" (10, 13 and 99) and have no section for it (AP21822 tech manual, p. 61; AP24838 tech manual, p. 56).
TechnicianRuud Mid-EfficiencyAP18000-2 manual p. 26; AP21822 tech manual p. 61; AP24838 tech manual p. 56
14“Water heater is overheating.”
What to check
The RTG-R-3 chart words it "Protective overheating wrap has been broken." (RTG-R-3 manual, p. 74). Troubleshooting manual name: "Over heat limiter is active"; the manual says this is normally caused by inadequate or wrong gas supply and/or venting (AP21822 tech manual, p. 41).
TechnicianRTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency
6 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 41; AP24838 tech manual p. 34; AP18000-2 manual p. 26
15“Excessively hot water detected”
Listed only in Rheem's troubleshooting manuals for service professionals: outlet or heat exchanger water above 207°F (97°C) for more than 15 seconds (AP21822 tech manual, p. 42). The Ruud Tankless Mid-Efficiency chart also lists 15, worded "The heat exchanger is too hot. Check for blockage in the vent.", with a call to a dealer or qualified service technician (AP18000-2 manual, p. 26).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 42; AP24838 tech manual p. 35
16“Outlet thermistor failure”
Listed only in Rheem's troubleshooting manual for service professionals. Shown when the outlet water temperature is above the set point (AP21822 tech manual, p. 42).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 42; AP24838 tech manual p. 35
17“Leak sensor has detected water.”
The meaning above is the RTG-R-3 chart's wording; the troubleshooting manuals head the code "Water leak detected" and say it is shown only when a Wi-Fi controller is used (AP21822 tech manual, p. 62; AP24838 tech manual, p. 57). Only the RTG-R-3 chart lists 17, with the remedy "There is a potential water leak. Contact a dealer or qualified service technician." (RTG-R-3 manual, p. 74). That manual's Leak Sensor section calls the alert "A017" (RTG-R-3 manual, p. 66).
TechnicianRTGH-3, RTG-3, RTG-R-3RTG-R-3 manual p. 74; AP21822 tech manual p. 62; AP24838 tech manual p. 57
24“DIP switch malfunction”
Listed only in Rheem's troubleshooting manual for service professionals. Shown when the UP/DOWN buttons on the built-in controller or remote are pressed for more than 20 seconds (AP21822 tech manual, p. 43).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 43; AP24838 tech manual p. 36
28“Low heat exchanger temperature detected”
Listed only in Rheem's troubleshooting manual for service professionals. Follows warning 05 when the heat exchanger thermistor keeps detecting a low temperature (AP21822 tech manual, p. 35).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 35; AP24838 tech manual p. 28
29“Neutralizer is clogged.”
What to check
The chart row gives only "Contact a dealer or qualified service technician." (RTGH-3 manual, p. 75). We class 29 as mixed because the owner maintenance list in the same manual includes checking the condensate line for blockage and, if a neutralizer is installed, checking its medium once a year (RTGH-3 manual, p. 68). The RTGH EZ guide words the cause "Condensation Trap is clogged." (RTGH EZ guide, p. 7). Troubleshooting manual name: "Condensation not drained from collector": the electrode in the built-in drain trap reads the water level as full, or cannot read it (AP21822 tech manual, p. 43). The RTG-3 chart and the RTG-R-3 troubleshooting manual have no code 29, and AP21822 labels the water level electrode "FOR CONDENSING MODEL ONLY" (AP21822 tech manual, p. 19).
Owner checks, then technicianRTGH-3RTGH-3 manual p. 75; RTGH EZ guide p. 7; AP21822 tech manual p. 43
31“Faulty inlet thermistor.”TechnicianRTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency
6 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 44; AP24838 tech manual p. 37; AP18000-2 manual p. 26
32“Heat exchanger thermistor malfunction”
Listed only in Rheem's troubleshooting manual for service professionals.
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 45; AP24838 tech manual p. 38
33“Faulty outlet thermistor.”TechnicianRTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency
6 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 46; AP24838 tech manual p. 39; AP18000-2 manual p. 26
34“Ambient/air supply thermistor malfunction”
Listed only in Rheem's troubleshooting manual for service professionals.
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 47; AP24838 tech manual p. 40
35“Improper thermistor connection”
Listed only in Rheem's troubleshooting manual for service professionals.
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 48; AP24838 tech manual p. 41
48“Water leak detection disabled”
Listed only in Rheem's troubleshooting manual for service professionals. Wi-Fi controller only: code 17 can be disabled through the Wi-Fi app for 24 hours, after which the heater shows warning 48 (AP21822 tech manual, p. 62).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 62; AP24838 tech manual p. 57
49“Water leak sensor not installed”
Listed only in Rheem's troubleshooting manual for service professionals. Shown only when a Wi-Fi controller is used (AP21822 tech manual, p. 62).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 62; AP24838 tech manual p. 57
51“Main gas solenoid valve (SV) malfunction”
Listed only in Rheem's troubleshooting manual for service professionals. The manual gives 51 and 52 the same explanation: the flame rod still detects flame a few seconds after the heater is turned off (AP21822 tech manual, pp. 49, 50).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 49; AP24838 tech manual p. 42
52“Proportional gas valve malfunction”
Listed only in Rheem's troubleshooting manual for service professionals. Same explanation as 51 in that manual (AP21822 tech manual, pp. 49, 50).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 50; AP24838 tech manual p. 43
61“Faulty blower motor.”
What to check
Troubleshooting manual name: "Blower motor speed incorrect for combustion": the RPM signal is incorrect after the fan starts (AP21822 tech manual, p. 51). The Ruud Tankless Mid-Efficiency chart prints this row as "61 or 99" (AP18000-2 manual, p. 26).
TechnicianRTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency
6 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 51; AP24838 tech manual p. 44; AP18000-2 manual p. 26
63“There is an abnormality in the pump's operation.”
The chart's remedy starts with an owner step: "Remove any blockage that would prevent the pump from flowing water.", then "Contact a dealer or qualified service technician." (RTG-R-3 manual, p. 74). Troubleshooting manual name: "Recirculation pump speed incorrect" (AP24838 tech manual, p. 45).
Owner checks, then technicianRTG-R-3RTG-R-3 manual p. 74; AP24838 tech manual p. 45
65“Water motor failed”
Listed only in Rheem's troubleshooting manual for service professionals; only the RTG-R-3 manual has a section for 65 (AP24838 tech manual, p. 46). AP21822 refers to a section 65 from codes 05 and 28 but has none (AP21822 tech manual, p. 35). The Ruud Tankless Mid-Efficiency chart also lists 65, worded "Faulty water flow solenoid.", with a call to a dealer or qualified service technician (AP18000-2 manual, p. 26).
TechnicianRTG-R-3AP24838 tech manual p. 46
66“Faulty bypass motor.”
The RTG-R-3 chart words it "Faulty water bypass motor" (RTG-R-3 manual, p. 74).
TechnicianRTGH-3, RTG-3, RTG-R-3
5 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 52; AP24838 tech manual p. 47
70“Microcomputer abnormality”
Listed only in Rheem's troubleshooting manual for service professionals.
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 53; AP24838 tech manual p. 48
71“Solenoid valve circuit failure.”
Only the RTGH-3 chart lists 71. Its solution cell also says "Flushing procedure may need to be repeated for excessive lime and scale build-up.", the sentence the troubleshooting manual prints for 1L (RTGH-3 manual, p. 75; AP21822 tech manual, p. 34). The RTG-3 and RTG-R-3 charts do not list 71; both troubleshooting manuals do (AP21822 tech manual, p. 54; AP24838 tech manual, p. 49).
TechnicianRTGH-3, RTG-3, RTG-R-3RTGH-3 manual p. 75; AP21822 tech manual p. 54; AP24838 tech manual p. 49
72“Flame rod detected flame before ignition”
Listed only in Rheem's troubleshooting manual for service professionals.
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 55; AP24838 tech manual p. 50
76“Built-in display (or remote controller) to water heater comm. failure”
Listed only in Rheem's troubleshooting manual for service professionals.
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 56; AP24838 tech manual p. 51
77“WiFi chip communication failure”
Listed only in Rheem's troubleshooting manual for service professionals. A warning shown only when a Wi-Fi controller is used (AP21822 tech manual, p. 63).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 63; AP24838 tech manual p. 58
79“Blower motor current failure”
Listed only in Rheem's troubleshooting manual for service professionals.
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 58; AP24838 tech manual p. 53
80“Detected flame presence after closing solenoid valves”
Listed only in Rheem's troubleshooting manual for service professionals.
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 59; AP24838 tech manual p. 54
82“Installed chip error”
Listed only in Rheem's troubleshooting manual for service professionals.
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 59; AP24838 tech manual p. 54
83“Configuration data restore failure”
Listed only in Rheem's troubleshooting manual for service professionals. A warning shown only when a Wi-Fi controller is used (AP21822 tech manual, p. 63).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 63; AP24838 tech manual p. 58
84“Configuration write limit exceeded”
Listed only in Rheem's troubleshooting manual for service professionals. A warning shown only when a Wi-Fi controller is used (AP21822 tech manual, p. 63).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 63; AP24838 tech manual p. 58
85“DIP switch not set for intended recirculation mode”
Listed only in Rheem's troubleshooting manual for service professionals. A warning shown only with a Wi-Fi controller on heaters installed with a recirculation line, when the DIP switch on the control board and the Wi-Fi app settings do not match (AP21822 tech manual, p. 64).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 64; AP24838 tech manual p. 59
88“Reminder of flushing the heat exchanger and/or replacing the water treatment filter.”
The reminder is off by default and can be set to 500, 750 or 1,000 hours of combustion (RTGH-3 manual, p. 76). The Use and Care manuals print a procedure to clear 88 after the maintenance is done (RTGH-3 manual, p. 77; RTG-3 manual, p. 79; RTG-R-3 manual, p. 76). The troubleshooting manual calls 88 a warning and says the unit will eventually shut down to protect itself (AP21822 tech manual, p. 60).
Owner checks, then technicianRTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency
6 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 60; AP24838 tech manual p. 55; AP18000-2 manual p. 26
89“High exhaust temperature detected”
Listed only in Rheem's troubleshooting manual for service professionals. An over temperature limit switch on the secondary heat exchanger has tripped; the manual says this is normally caused by inadequate or wrong gas supply and/or venting (AP21822 tech manual, p. 61).
TechnicianRTGH-3, RTG-3, RTG-R-3AP21822 tech manual p. 61; AP24838 tech manual p. 56
90“Air intake or vent exhaust opening may be blocked.”
What to check
The charts print one row for "90 or 99", with a second cause: "The vent pipes on the vent termination may not be connected properly." The troubleshooting manual says 90 occurs before the unit goes into ignition and 99 after it shuts down (AP21822 tech manual, p. 61).
Owner checks, then technicianRTGH-3, RTG-3, RTG-R-3
5 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 61; AP24838 tech manual p. 56
99“Air intake or vent exhaust opening may be blocked.”
What to check
Same chart row as 90 ("90 or 99"). The troubleshooting manual says 99 occurs after the unit shuts down and lists it with 10 and 13 as a "hard lockout" whose reset starts with removing the front cover (AP21822 tech manual, p. 61). Ruud Tankless Mid-Efficiency heaters use 99 for something else: their chart prints "61 or 99" as "Faulty blower motor.", with a call to a dealer or qualified service technician (AP18000-2 manual, p. 26).
Owner checks, then technicianRTGH-3, RTG-3, RTG-R-3
5 documentsRTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 61; AP24838 tech manual p. 56
102-106“Manifolding communication error.”
Manifolded installations only. The troubleshooting manual lists each code: 102 is "Manifolding comm. error between unit 2 and manager unit", and 103, 104, 105 and 106 are the same for units 3 to 6 (AP24838 tech manual, p. 59). The chart refers to the manual's Multiple Unit Controls section (RTG-R-3 manual, p. 74).
TechnicianRTG-R-3RTG-R-3 manual p. 74; AP24838 tech manual p. 59
149“Water leak sensor not installed”
Listed only in Rheem's troubleshooting manual for service professionals. Shown only when a Wi-Fi controller is used, if the leak sensor is missing or its connection to the display wire harness is lost (AP24838 tech manual, p. 59).
TechnicianRTG-R-3AP24838 tech manual p. 59
176“Wifi display to water heater communication error.”
The chart's remedy is "Confirm the cable connections are installed properly." (RTG-R-3 manual, p. 74). We class it as technician work because the same manual tells owners not to repair electrical wiring or the remote control (RTG-R-3 manual, p. 5).
TechnicianRTG-R-3RTG-R-3 manual p. 74; AP24838 tech manual p. 60
195“The manager heater detects a failure in one of the manifolded heaters.”
Manifolded installations only. The chart refers to the manual's Multiple Unit Controls section (RTG-R-3 manual, p. 74).
TechnicianRTG-R-3RTG-R-3 manual p. 74; AP24838 tech manual p. 60
196“The manifolded unit detects incorrect local dip switch setting”
Listed only in Rheem's troubleshooting manual for service professionals. Manifolded installations only (AP24838 tech manual, p. 60).
TechnicianRTG-R-3AP24838 tech manual p. 60
A01L“Water heater has buildup of lime deposits.”
The IKONIC service manual uses A018 for lime build-up (IKONIC service manual, p. 44). Neither document says that A01L and A018 are the same code.
TechnicianIKONICIKONIC manual p. 107
A011“The gas shut-off valve is not fully opened.”
The IKONIC chart's remedy also asks you to check that venting and the air supply are not blocked (IKONIC manual, p. 107). Service manual name: "Flame Not Detected From Flame Rod", after 10 ignition attempts (IKONIC service manual, p. 38).
Owner checks, then technicianIKONICIKONIC manual p. 107; IKONIC service manual p. 38
A012“Gas service has been interrupted.”
Second row: "LP gas is running low (LP models only)." Service manual name: "Unit Detected Flame and Lost It", after 15 flame losses in a row (IKONIC service manual, p. 41).
Owner checks, then technicianIKONICIKONIC manual p. 107; IKONIC service manual p. 41
A014“Water heater is overheating.”
Service manual name: "Over Heat Limiter (OHL) activated"; the heater has an Over Heat Limiter and an Over Heat Limit Fuse (IKONIC service manual, p. 43).
TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 43
A017“Leak sensor has detected water.”
The chart points to the manual's Leak Sensor section: if water is found outside the heater, contact a dealer or qualified service technician immediately; if no leak is found, a 24-hour override is available in the SETTINGS menu (IKONIC manual, p. 103). The IKONIC service manual does not list A017.
Owner checks, then technicianIKONICIKONIC manual p. 107; IKONIC manual p. 103
A018“Lime build-up inside the heat exchanger”
Listed only in Rheem's IKONIC service manual for service professionals. The IKONIC Use and Care chart shows lime build-up as A01L (IKONIC manual, p. 107).
TechnicianIKONICIKONIC service manual p. 44
A029“Blocked condensate line.”
Service manual name: "Condensate blockage" (IKONIC service manual, p. 45). The IKONIC manual asks owners to inspect the condensate drain line on a regular basis (IKONIC manual, p. 94).
Owner checks, then technicianIKONICIKONIC manual p. 107; IKONIC service manual p. 45
A031“Faulty inlet water thermistor.”TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 46
A032“Faulty heat exchanger thermistor.”TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 47
A033“Faulty outlet water thermistor.”TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 48
A035“Improper thermistor connection.”TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 49
A036“Faulty exhaust thermistor.”TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 50
A055“Faulty gas valve.”
Service manual name: "Gas motor failed", the motor that positions the butterfly valve in the venturi (IKONIC service manual, p. 51).
TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 51
A061“Faulty blower motor.”TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 52
A063“(Built-in recirculation) pump abnormality.”
SR models only (IKONIC manual, p. 107).
TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 53
A065“Faulty water flow solenoid.”
Service manual name: "Water volume control valve malfunction" (IKONIC service manual, p. 54).
TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 54
A066“Faulty bypass solenoid.”
Service manual name: "Water bypass control valve malfunction" (IKONIC service manual, p. 55).
TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 55
A070“Faulty control board.”
Service manual name: "Microcomputer Abnormality" (IKONIC service manual, p. 56).
TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 56
A071“Faulty gas solenoid valve.”
Service manual name: "Gas Air ratio valve malfunction": the flame rod detects flame for 8 seconds after the heater is turned off (IKONIC service manual, p. 57).
TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 57
A072“Flame detected before ignition.”
Service manual name: "Flame rod malfunction" (IKONIC service manual, p. 58).
TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 58
A082“Software error.”
Service manual name: "Installed Chip Error", a problem with the gas chip on the control board (IKONIC service manual, p. 59).
TechnicianIKONICIKONIC manual p. 107; IKONIC service manual p. 59
A090“Air intake or vent exhaust opening may be blocked.”
Two more rows in the IKONIC chart: "The vent pipes on the vent termination may not be connected properly." and "Blocked vent termination or inlet air filter.", both with "Contact a dealer or qualified service technician." (IKONIC manual, p. 107).
Owner checks, then technicianIKONICIKONIC manual p. 107; IKONIC service manual p. 60
A200“Water Heater Communication Failure.”
Listed only in Rheem's IKONIC service manual for service professionals: the user interface is not communicating with the control board (IKONIC service manual, p. 61).
TechnicianIKONICIKONIC service manual p. 61
A2##“WATER HEATER COMM. FAILURE INSTANCE ## (## IS NO.02 TO NO,20)”
Listed only in Rheem's IKONIC service manual for service professionals. In a manifold of up to 20 heaters, the manager heater shows A2## when another heater has an error, where ## is that heater's instance number; the manual's example is A205 (IKONIC service manual, p. 62). Quoted as printed.
TechnicianIKONICIKONIC service manual p. 62
T110“WiFi chip communication error”
Listed only in Rheem's IKONIC service manual for service professionals.
TechnicianIKONICIKONIC service manual p. 63
T111“Reminder of flushing the heat exchanger and/or replacing the water tratment filter”
Quoted as printed ("tratment"). The service alert can be set to 500, 750 or 1000 hours; the Use and Care manual gives the factory setting as OFF (IKONIC manual, p. 76), the service manual as 500 hours (IKONIC service manual, p. 35). The service manual calls T111 a warning after which the unit will eventually shut down (IKONIC service manual, p. 64). Alarms are cleared from the SERVICE menu (IKONIC manual, p. 106).
Owner checks, then technicianIKONICIKONIC manual p. 107; IKONIC service manual p. 64
T113“Not enough hot water to operate the unit.”
The chart's remedy is printed "Increase the water flow from the fuxtures." (IKONIC manual, p. 107). The service manual says the flow rate is less than 0.4 GPM and the heater will not activate (IKONIC service manual, p. 65).
Owner can checkIKONICIKONIC manual p. 107; IKONIC service manual p. 65
T115“Pump schedule disable - No time received.”
Listed only in Rheem's IKONIC service manual for service professionals. Applies to heaters installed with a recirculation line and a pump schedule; the manual says to recheck the scheduled time in the EcoNet app (IKONIC service manual, p. 66).
TechnicianIKONICIKONIC service manual p. 66
T116“Manifold unit fault.”
Listed only in Rheem's IKONIC service manual for service professionals. Manifolded installations only (IKONIC service manual, p. 66).
TechnicianIKONICIKONIC service manual p. 66
F000“Heat exchanger temperature sensor fault.”TechnicianThermaForceI&O manual 84160404 p. 5-5; Controller manual 84162404 p. 1-40
F002“High heat exchanger temperature during DHW demand.”TechnicianThermaForceI&O manual 84160404 p. 5-5; Controller manual 84162404 p. 1-40
F003“High flue temperature.”TechnicianThermaForceI&O manual 84160404 p. 5-5; Controller manual 84162404 p. 1-40
F004“No flame detected during four ignition trials.”
The installation manual's list starts with verifying that the external gas shutoff valve is open, then moves to gas inlet pressure, the condensate drain, venting, grounding, the ignitor and replacement of parts (I&O manual 84160404, p. 5-5).
TechnicianThermaForceI&O manual 84160404 p. 5-5; Controller manual 84162404 p. 1-40
F005“No flame detected during operation.”TechnicianThermaForceI&O manual 84160404 p. 5-6; Controller manual 84162404 p. 1-41
F006“Flame detected when burner is off.”TechnicianThermaForceI&O manual 84160404 p. 5-6; Controller manual 84162404 p. 1-41
F007“Low flame signal.”TechnicianThermaForceI&O manual 84160404 p. 5-6; Controller manual 84162404 p. 1-41
F008“Incorrect fan speed”TechnicianThermaForceI&O manual 84160404 p. 5-6; Controller manual 84162404 p. 1-41
F009“Control module internal fault.”TechnicianThermaForceI&O manual 84160404 p. 5-6; Controller manual 84162404 p. 1-41
F010“Heat exchanger temperature sensor open.”TechnicianThermaForceI&O manual 84160404 p. 5-6; Controller manual 84162404 p. 1-41
F011“Heat exchanger temperature sensor short.”
Listed in the installation manual (I&O manual 84160404, p. 5-6); the table in Controller manual 84162404 does not include F011.
TechnicianThermaForceI&O manual 84160404 p. 5-6
F012“Flue temperature sensor open.”TechnicianThermaForceI&O manual 84160404 p. 5-6; Controller manual 84162404 p. 1-41
F013“DHW inlet temperature sensor open/short”TechnicianThermaForceI&O manual 84160404 p. 5-7; Controller manual 84162404 p. 1-41
F014“Heat exchanger temperature sensor mounting fault.”TechnicianThermaForceI&O manual 84160404 p. 5-7; Controller manual 84162404 p. 1-41
F015“High cabinet temperature”TechnicianThermaForceI&O manual 84160404 p. 5-7; Controller manual 84162404 p. 1-41
F016“DHW outlet temperature sensor mounting fault”TechnicianThermaForceI&O manual 84160404 p. 5-7; Controller manual 84162404 p. 1-41
F017“DHW bypass valve fault”TechnicianThermaForceI&O manual 84160404 p. 5-7; Controller manual 84162404 p. 1-42
F018“Flue/Combustion Air blockage.”
The user's manual does not name F018, but says that if a vent blockage is easily accessible and removable, remove it and reset the unit by touching the wrench for 2 seconds; if it is not, contact a qualified service agency (User's manual 84161404, p. 4).
Owner checks, then technicianThermaForceI&O manual 84160404 p. 5-7; Controller manual 84162404 p. 1-42; User's manual 84161404 p. 4
F019“Boiler Memory Module (BMM) fault.”TechnicianThermaForceI&O manual 84160404 p. 5-7; Controller manual 84162404 p. 1-42
F021“Critical parameter changed”TechnicianThermaForceI&O manual 84160404 p. 5-7; Controller manual 84162404 p. 1-42
F028“Reset button fault”TechnicianThermaForceI&O manual 84160404 p. 5-7; Controller manual 84162404 p. 1-42
F029“Gas valve fault.”TechnicianThermaForceI&O manual 84160404 p. 5-7; Controller manual 84162404 p. 1-42
F040“Cabinet temperature sensor open.”TechnicianThermaForceI&O manual 84160404 p. 5-8; Controller manual 84162404 p. 1-42
F041“Cabinet temperature sensor short”TechnicianThermaForceI&O manual 84160404 p. 5-8; Controller manual 84162404 p. 1-42
F042“Cascade DHW not available”TechnicianThermaForceI&O manual 84160404 p. 5-8; Controller manual 84162404 p. 1-42
-- (Blinking)“Water presssure sensor fault”
Printed without a number, as two blinking dashes. Quoted as printed ("presssure").
TechnicianThermaForceI&O manual 84160404 p. 5-8; Controller manual 84162404 p. 1-43
n030“DHW outlet temperature sensor open/short”TechnicianThermaForceI&O manual 84160404 p. 5-9; Controller manual 84162404 p. 1-44
n040“Cascade communication lost”TechnicianThermaForceI&O manual 84160404 p. 5-9; Controller manual 84162404 p. 1-44
n041“Cascade system sensor open”TechnicianThermaForceI&O manual 84160404 p. 5-9; Controller manual 84162404 p. 1-44
n120“Maintenance recommended”
Based on hours of use (I&O manual 84160404, p. 5-9). The user's manual says annual maintenance must only be done by a qualified service technician (User's manual 84161404, p. 12).
TechnicianThermaForceI&O manual 84160404 p. 5-9; Controller manual 84162404 p. 1-44
n121“Maintenance required, limited DHW output”
Hot water output stays limited until maintenance is performed (I&O manual 84160404, p. 5-9).
TechnicianThermaForceI&O manual 84160404 p. 5-9; Controller manual 84162404 p. 1-44
n122“Maintenance required, no DHW output”
Hot water output is disabled until maintenance is performed (I&O manual 84160404, p. 5-9).
TechnicianThermaForceI&O manual 84160404 p. 5-9; Controller manual 84162404 p. 1-44
n150“High heat exchanger temperature, limited output”TechnicianThermaForceI&O manual 84160404 p. 5-9; Controller manual 84162404 p. 1-44
n151“High flue temperature, limited output”TechnicianThermaForceI&O manual 84160404 p. 5-9; Controller manual 84162404 p. 1-45
n152“Flue temperature sensor mounting fault”TechnicianThermaForceI&O manual 84160404 p. 5-10; Controller manual 84162404 p. 1-45
n201“Heat exchanger air purge function activated”TechnicianThermaForceI&O manual 84160404 p. 5-10; Controller manual 84162404 p. 1-45
n202“High flue temperature, burner disabled”TechnicianThermaForceI&O manual 84160404 p. 5-10; Controller manual 84162404 p. 1-45
n245“Flue gas back flow, fan on low speed”TechnicianThermaForceI&O manual 84160404 p. 5-10; Controller manual 84162404 p. 1-45

What to check, code by code

Rheem tankless code P1 (not enough water flow): what to check

Checked

Rheem display

P1

“Not enough water flow to operate the unit.”

Owner can check

Printed on 4 model series · 6 documents

RTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency · RTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 34; AP24838 tech manual p. 27; AP18000-2 manual p. 26

The RTG-R-3 chart adds "Water flow was low during recirculation cycle." and asks you to confirm there is no debris in the inlet water filter (RTG-R-3 manual, p. 74). The troubleshooting manual gives 0.4 GPM as the minimum flow to activate the heater (AP21822 tech manual, p. 34).

Short answer On Rheem RTGH-3, RTG-3 and RTG-R-3 heaters, P1 means there is not enough water flow to operate the unit. Open the hot tap fully, check that the water shut-off valve is completely open and clean the aerator; call for service if P1 stays. See what to check

What it means

P1 means the water flow is too low for the heater to run. It needs at least 0.4 gpm (1.5 L/min) to start (RTGH-3 and RTG-3 Troubleshooting Manual, AP21822, p. 34; RTG-R-3 Troubleshooting Manual, AP24838, p. 27; RTGH-3 Use and Care Manual, p. 38). The RTG-3 and RTG-R-3 manuals add that it needs at least 0.25 gpm (1.01 L/min) to keep running (RTG-3 Use and Care Manual, p. 36; RTG-R-3 Use and Care Manual, p. 36). Operation also needs at least 14 psi (97 kPa) of water pressure, and 40 psi (276 kPa) for the maximum flow rate (RTGH-3 manual, p. 38).

The chart’s remedy is to increase the water flow from the fixtures (RTGH-3 manual, p. 75).

Check these first

Most of these steps come from Rheem’s troubleshooting chart for “Not enough or no hot water” (RTGH-3 manual, p. 72; RTG-3 manual, p. 74; RTG-R-3 manual, p. 71).

  1. Open the hot tap all the way. The main burner goes off when the incoming water volume is inadequate (RTGH-3 manual, p. 72).
  2. Make sure the water shut-off valve to the heater is completely open (RTGH-3 manual, p. 72).
  3. Clean the aerator on the tap if it is clogged or dirty (RTGH-3 manual, p. 72).
  4. If the water piping may be frozen, let it thaw (RTGH-3 manual, p. 72).
  5. Before you touch the inlet water filter, drain the heater as the manual describes; its warning is about scalding. Turn the heater off, close the gas shut-off valve, unplug the heater at least 10 seconds later, run the hot water until it is cold, close the water shut-off valve and open the drain valve (RTGH-3 manual, p. 69; RTG-3 manual, p. 71; RTG-R-3 manual, p. 68).
  6. Clean the inlet water filter at the base of the cold water inlet line. On RTG-R-3 heaters the P1 row asks for this check directly (RTG-R-3 manual, p. 74). Unscrew the filter without tapping or forcing it, rinse it under running water, using a soft brush for heavy sediment, and screw it back until snug without overtightening (RTGH-3 manual, pp. 66–67; RTG-3 manual, pp. 68–69; RTG-R-3 manual, pp. 65–66). To put the heater back in service, close the drain valve, open the water shut-off valve, run the hot taps until the air is out, reconnect power, open the gas shut-off valve and press POWER ON/OFF (RTGH-3 manual, p. 70; RTG-3 manual, p. 72; RTG-R-3 manual, p. 69).
  7. If P1 is still shown, run the reset sequence from the chart section and call for service if the code stays (RTGH-3 manual, p. 74).

When to call a licensed technician

  • P1 stays with the tap wide open, a clean aerator and a clean filter.
  • Hot and cold water lines reversed at the heater. The chart’s fix is to reverse them (RTGH-3 manual, p. 72), and Rheem says plumbing should be done by a qualified plumbing contractor (RTGH-3 manual, p. 38).
  • Low house water pressure. Rheem’s sizing formula adds pipe and faucet pressure losses and a safety margin of more than 5 psi (34 kPa) to the 14 psi minimum (RTGH-3 manual, p. 38).
  • The troubleshooting manual’s checks, written for technicians and service professionals only (AP21822 tech manual, p. 7): debris in the heat exchanger, which calls for flushing; a blocked water flow sensor; a plumbing cross-over in the house; and a flow reading in maintenance mode, where more than 0.4 gpm with no firing points to the control board (AP21822 tech manual, p. 34).

Notes for different models

The RTGH-3 troubleshooting chart sends you to page 75 for the water filter, but the cleaning steps are on pp. 66–67 (RTGH-3 manual, p. 72). The RTG-3 and RTG-R-3 charts point to the right pages (RTG-3 manual, p. 74; RTG-R-3 manual, p. 71).

IKONIC heaters use T113; their service manual describes it as a flow rate below 0.4 gpm (IKONIC Use and Care Manual, p. 107; IKONIC Technical Training and Service Manual, p. 65). The chart for Ruud Tankless Mid-Efficiency heaters prints the same P1 row as the -3 charts (Tankless Water Heater Use and Care Manual AP18000-2, p. 26).

Related codes: 1L, 63, T113. All Rheem codes

Rheem tankless code 11 (flame not detected): what to check

Checked

Rheem display

11

“The gas shut-off valve is not fully opened.”

Owner checks, then technician

Printed on 4 model series · 6 documents

RTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency · RTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 37; AP24838 tech manual p. 30; AP18000-2 manual p. 26

Troubleshooting manual name: "Flame Not Detected by Flame Rod". The heater attempts ignition 2 times before it shows 11 (AP21822 tech manual, p. 37).

Short answer Rheem code 11 means the burner did not light, and Rheem's charts point to a gas shut-off valve that is not fully open. Reset the heater and check that the valve is fully open; if 11 is still shown, call for service. See what to check

What it means

Code 11 means the burner did not light. After an ignition failure the heater tries to light 2 times, and if its flame rod still detects no flame, it shows 11 (RTGH-3 and RTG-3 Troubleshooting Manual, AP21822, p. 37; RTG-R-3 Troubleshooting Manual, AP24838, p. 30). The owner charts give one cause and one remedy: check the gas shut-off valve and open it completely (RTGH-3 Use and Care Manual, p. 75; RTG-3 Use and Care Manual, p. 77; RTG-R-3 Use and Care Manual, p. 74).

These heaters have no pilot. An ignition device lights the burner, and the label says not to try lighting it by hand (RTGH-3 manual, p. 6).

Check these first

If a gas leak is present or suspected, do not try to find the cause yourself (RTGH-3 manual, p. 5).

  1. Close all hot water taps. Turn the heater off with the POWER ON/OFF button on the remote control, wait about 5 minutes, turn it back on, then open a hot tap and check the display (RTGH-3 manual, p. 74; RTG-3 manual, p. 76; RTG-R-3 manual, p. 73).
  2. If 11 is still shown, close the tap, turn the heater off, unplug it for about 30 seconds and plug it back in (RTGH-3 manual, p. 74).
  3. Check that the gas shut-off valve is fully open (RTGH-3 manual, p. 75). The label’s operating instructions place this valve on the outside of the unit; it turns counterclockwise to ON (RTGH-3 manual, p. 6). Rheem says not to turn the heater on unless the gas and water supplies are completely open (RTGH-3 manual, p. 5).
  4. If the valve was closed, reopen it the way the label describes: turn off electric power to the heater, set the valve to OFF and wait five minutes. Then smell for gas around the heater, including next to the floor. If you smell gas, stop and follow the gas steps above. If you do not, turn the valve to ON and turn the power back on (RTGH-3 manual, p. 6).
  5. Restart the heater, open a hot tap and check the display. If 11 is still shown, turn the heater off, write down the code and call for service (RTGH-3 manual, p. 74). The label adds that if the heater will not operate, you turn off the gas to it and call your service technician or gas supplier (RTGH-3 manual, p. 6).

When to call a licensed technician

  • Code 11 comes back after the valve check and the reset.
  • Anything on the troubleshooting manual’s list for 11. Rheem writes that manual for technicians and service professionals only (AP21822 tech manual, p. 7). Its checks are the gas supply pressure at the heater’s gas connection, measured at standby and at maximum firing; the gas filter at that connection; the vent connections and termination; DIP switch settings for venting and altitude; and the igniter and flame rods (AP21822 tech manual, p. 37).
  • The pressure window the technician checks against is 4.0–10.5 in. w.c. for natural gas and 8.0–13.0 in. w.c. for propane (AP21822 tech manual, p. 37; RTGH-3 manual, p. 5). If the pressure is too high or too low, the Use and Care manual says to contact your gas supplier for correction (RTGH-3 manual, p. 45).
  • The charts do not link 11 to gas line size. The RTGH-3 manual does say that an undersized flexible gas connector will cause operational issues, and that half-inch gas lines are permitted only when the system pressure is 8.0 in. w.c. or more and the pipe capacity table is followed (RTGH-3 manual, p. 43). Gas piping is not an owner repair (RTGH-3 manual, p. 5).
  • Above 2,000 ft (610 m), a qualified service technician makes the altitude adjustments (RTGH-3 manual, p. 47).

Notes for different models

The RTGH-3, RTG-3 and RTG-R-3 charts print the same row for 11, and so does the chart for Ruud Tankless Mid-Efficiency heaters (Tankless Water Heater Use and Care Manual AP18000-2, p. 26).

IKONIC heaters show A011 for the same cause. Their chart also asks you to check that venting and the air supply are not blocked (IKONIC Use and Care Manual, p. 107), and the service manual says the heater makes 10 ignition attempts before it shows A011 (IKONIC Technical Training and Service Manual, p. 38).

Related codes: 12, 72, 90. All Rheem codes

Rheem tankless code 12 (flame lost): what to check

Checked

Rheem display

12

“Gas service has been interrupted.”

Owner checks, then technician

Printed on 4 model series · 6 documents

RTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency · RTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 40; AP24838 tech manual p. 33; AP18000-2 manual p. 26

Second row in the same charts: "LP gas is running low (LP models only)." Troubleshooting manual name: "Detected Presence of Flame, Then Lost it", shown after the flame is lost 3 times in a row (AP21822 tech manual, p. 40). The EZ installation guides give "Check gas supply." as the first remedy, and the RTGH guide adds a DIP switch row (RTGH EZ guide, p. 7; RTG EZ guide, p. 2; RTG-R EZ guide, p. 2).

Short answer Rheem code 12 means the burner lit and then lost its flame; the charts name interrupted gas service or, on LP models, propane running low. Reset the heater, then contact your gas utility or refill the LP container; if 12 remains, call for service. See what to check

What it means

Code 12 means the burner lit and then went out. When the heater loses its flame while burning, it stops the fuel, tries to restart and counts the losses; after 3 in a row it shows 12 (RTGH-3 and RTG-3 Troubleshooting Manual, AP21822, p. 40; RTG-R-3 Troubleshooting Manual, AP24838, p. 33). The owner charts list two causes, each with its own remedy: interrupted gas service, and on LP models a propane supply that is running low (RTGH-3 Use and Care Manual, p. 75; RTG-3 Use and Care Manual, p. 77; RTG-R-3 Use and Care Manual, p. 74).

Check these first

If a gas leak is present or suspected, do not try to find the cause yourself (RTGH-3 manual, p. 5).

  1. Close all hot water taps. Turn the heater off with the POWER ON/OFF button on the remote control, wait about 5 minutes, turn it back on, then open a hot tap and check the display (RTGH-3 manual, p. 74; RTG-3 manual, p. 76; RTG-R-3 manual, p. 73).
  2. If 12 is still shown, close the tap, turn the heater off, unplug it for about 30 seconds and plug it back in (RTGH-3 manual, p. 74).
  3. If gas service to the house may have been interrupted, contact your gas utility company. That is the chart’s remedy for the first cause (RTGH-3 manual, p. 75).
  4. On a propane heater, refill or replace the LP gas container (RTGH-3 manual, p. 75). The data plate shows which fuel your heater is built for (RTGH-3 manual, p. 5).
  5. Restart the heater, open a hot tap and check the display. If 12 is still shown, turn the heater off, write down the code and call for service (RTGH-3 manual, p. 74).

When to call a licensed technician

  • Code 12 comes back while the gas supply is on and the propane tank has fuel.
  • Anything on the troubleshooting manual’s list for 12. Rheem writes that manual for technicians and service professionals only (AP21822 tech manual, p. 7). Its checks are the gas supply pressure at the heater’s gas connection, the gas filter at that connection, the vent connections and termination, the flame rod, and DIP switch settings for venting and altitude (AP21822 tech manual, p. 40).
  • The manual explains why pressure is measured twice, at standby and at maximum firing: it can be normal at standby and still drop when another gas appliance runs (AP21822 tech manual, p. 40). The correct range is 4.0–10.5 in. w.c. for natural gas and 8.0–13.0 in. w.c. for propane (AP21822 tech manual, p. 40). If the pressure is too high or too low, the Use and Care manual says to contact your gas supplier for correction (RTGH-3 manual, p. 45).
  • Above 2,000 ft (610 m), a qualified service technician makes the altitude adjustments (RTGH-3 manual, p. 47).

Notes for different models

The EZ installation guides word the remedies differently. All three give “Check gas supply.” for interrupted gas service and send a low gas supply to a dealer or qualified service technician (RTGH Tankless Easy Installation Guide, p. 7; RTG Tankless Easy Installation Guide, p. 2; RTG-R Tankless Easy Installation Guide, p. 2). The RTGH guide adds a row for DIP switch settings (RTGH EZ guide, p. 7). Those switches sit on the control board behind the front cover (AP21822 tech manual, p. 61), and only a qualified service technician should remove that cover (RTGH-3 manual, p. 49).

IKONIC heaters show A012, with the same two causes in their chart (IKONIC Use and Care Manual, p. 107). The IKONIC service manual counts 15 flame losses in a row before A012 instead of 3 (IKONIC Technical Training and Service Manual, p. 41). The chart for Ruud Tankless Mid-Efficiency heaters prints the same two rows for 12 (Tankless Water Heater Use and Care Manual AP18000-2, p. 26).

Related codes: 11, 90, 80. All Rheem codes

Rheem tankless code 14 (overheat limiter): what to check

Checked

Rheem display

14

“Water heater is overheating.”

Technician

Printed on 4 model series · 6 documents

RTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency · RTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 41; AP24838 tech manual p. 34; AP18000-2 manual p. 26

The RTG-R-3 chart words it "Protective overheating wrap has been broken." (RTG-R-3 manual, p. 74). Troubleshooting manual name: "Over heat limiter is active"; the manual says this is normally caused by inadequate or wrong gas supply and/or venting (AP21822 tech manual, p. 41).

Short answer On Rheem RTGH-3 and RTG-3 heaters, code 14 means the water heater is overheating (on RTG-R-3, a broken protective overheating wrap). The charts' only remedy is to contact a dealer or qualified service technician. See what to check

What it means

Code 14 comes from the heater’s Over Heat Limiter (OHL). When the OHL has been activated or broken, the heater shows 14. Rheem’s troubleshooting manual says this is normally caused by an inadequate or wrong gas supply and/or venting (RTGH-3 and RTG-3 Troubleshooting Manual, AP21822, p. 41; RTG-R-3 Troubleshooting Manual, AP24838, p. 34). All three owner charts give a single remedy: contact a dealer or qualified service technician (RTGH-3 Use and Care Manual, p. 75; RTG-3 Use and Care Manual, p. 77; RTG-R-3 Use and Care Manual, p. 74).

Check these first

The charts give owners no fix for 14 itself. These steps come from other parts of the same manuals.

If a gas leak is present or suspected, do not try to find the cause yourself (RTGH-3 manual, p. 5).

  1. If the heater has overheated or the gas supply does not shut off, turn off the manual gas shut-off valve to the heater. This comes from Rheem’s safety warnings (RTGH-3 manual, p. 5; RTG-3 manual, p. 5; RTG-R-3 manual, p. 5); the chart row for 14 does not mention it.
  2. Reset once, as the chart section asks for any code. Close all hot water taps, turn the heater off with the POWER ON/OFF button on the remote control, wait about 5 minutes, turn it back on and open a hot tap (RTGH-3 manual, p. 74; RTG-3 manual, p. 76; RTG-R-3 manual, p. 73).
  3. If 14 is still shown, turn the heater off, unplug it for about 30 seconds, plug it back in and restart. If 14 remains, turn the heater off, write down the code and call for service (RTGH-3 manual, p. 74).
  4. With the heater off, check the air intake and vent outlet outside for blockage or debris. The intake needs at least 12 in. (30 cm) of clearance from any obstruction (RTGH-3 manual, p. 66; RTG-3 manual, p. 68; RTG-R-3 manual, p. 65). This is a routine care check, not a remedy from the code 14 row; Rheem asks that all care around the heater be done with it turned off and its power disconnected (RTGH-3 manual, p. 66).

When to call a licensed technician

  • Every case of 14. That is the only remedy the charts give.
  • The technician checks the OHL itself, and the gas supply and venting that the troubleshooting manual names as the usual causes (AP21822 tech manual, p. 41). Rheem writes that manual for technicians and service professionals only (AP21822 tech manual, p. 7).
  • Inlet gas pressure must stay within 4.0–10.5 in. w.c. for natural gas and 8.0–13.0 in. w.c. for propane; outside that range a gas pressure regulator must be installed (RTGH-3 manual, p. 5).
  • The venting system should be inspected once a year to make sure every section is secure and airtight. The RTGH-3 manual says qualified service personnel can advise on this (RTGH-3 manual, p. 64); the RTG-3 and RTG-R-3 manuals assign the inspection to a qualified service technician (RTG-3 manual, p. 66; RTG-R-3 manual, p. 63).
  • Do not run the heater if the vent system shows signs of leaking exhaust (RTGH-3 manual, p. 64; RTG-3 manual, p. 66; RTG-R-3 manual, p. 63).

Notes for different models

The RTG-R-3 chart describes 14 as a broken protective overheating wrap rather than an overheating heater, with the same remedy (RTG-R-3 manual, p. 74).

IKONIC heaters use A014, with the same chart row as the RTGH-3 (IKONIC Use and Care Manual, p. 107). Their service manual says these heaters have both an Over Heat Limiter and an Over Heat Limit Fuse, and that A014 appears if either one has been activated (IKONIC Technical Training and Service Manual, p. 43).

The chart for Ruud Tankless Mid-Efficiency heaters prints the same row for 14 (Tankless Water Heater Use and Care Manual AP18000-2, p. 26).

Related codes: 89, 15, 90. All Rheem codes

Rheem tankless code 29 (condensate not draining): what to check

Checked

Rheem display

29

“Neutralizer is clogged.”

Owner checks, then technician

RTGH-3 · RTGH-3 Use and Care Manual, p. 75; RTGH Tankless Easy Installation Guide, p. 7; RTGH-3 and RTG-3 Troubleshooting Manual, p. 43

The chart row gives only "Contact a dealer or qualified service technician." (RTGH-3 manual, p. 75). We class 29 as mixed because the owner maintenance list in the same manual includes checking the condensate line for blockage and, if a neutralizer is installed, checking its medium once a year (RTGH-3 manual, p. 68). The RTGH EZ guide words the cause "Condensation Trap is clogged." (RTGH EZ guide, p. 7). Troubleshooting manual name: "Condensation not drained from collector": the electrode in the built-in drain trap reads the water level as full, or cannot read it (AP21822 tech manual, p. 43). The RTG-3 chart and the RTG-R-3 troubleshooting manual have no code 29, and AP21822 labels the water level electrode "FOR CONDENSING MODEL ONLY" (AP21822 tech manual, p. 19).

Short answer On Rheem RTGH-3 heaters, the owner chart lists code 29 as 'Neutralizer is clogged'; the technician manual says condensate is not draining from the built-in trap. Check the drain line and any neutralizer medium; if 29 remains, call a dealer or qualified service technician. See what to check

What it means

RTGH-3 heaters are condensing models with a built-in drain trap for condensate. An electrode in the trap senses the water level. If the trap reads full, or the electrode cannot detect the level at all, the heater shows 29 (RTGH-3 and RTG-3 Troubleshooting Manual, AP21822, p. 43). The RTGH-3 Use and Care Manual says that if the condensate drain gets blocked, an error code appears and the drain must be cleared (RTGH-3 manual, p. 41). Condensate is acidic (RTGH-3 manual, p. 64).

Check these first

The chart row for 29 has one remedy: contact a dealer or qualified service technician (RTGH-3 manual, p. 75). The owner maintenance list in the same manual covers the drain line and the neutralizer (RTGH-3 manual, p. 68), so an owner can check both before the call.

  1. Close all hot water taps. Turn the heater off with the POWER ON/OFF button on the remote control, wait about 5 minutes, turn it back on and open a hot tap. If 29 is still shown, turn the heater off, unplug it for about 30 seconds and plug it back in (RTGH-3 manual, p. 74). Keep the heater turned off for the checks below.
  2. Look along the condensate drain line you can see for a blockage. Checking it is on the owner maintenance list (RTGH-3 manual, p. 68), and the manual asks owners to inspect the drain line regularly to make sure condensate drains properly (RTGH-3 manual, p. 64).
  3. Look at the end of the drain line. Rheem’s installation section says it should be open to the air, not under water or anything else, with the line sloping down toward the end (RTGH-3 manual, p. 41). In cold climates the drain may need protection from freezing (RTGH-3 manual, p. 41).
  4. If a condensate neutralizer is installed, check that its medium is still there. The owner list calls for this once a year and says to replace the neutralizer if the medium is used up (RTGH-3 manual, p. 68).
  5. Restart the heater and open a hot tap. If 29 is still shown, turn the heater off, write down the code and call for service (RTGH-3 manual, p. 74).

When to call a licensed technician

  • A clogged neutralizer: the chart sends it to a dealer or qualified service technician (RTGH-3 manual, p. 75).
  • Code 29 coming back after the checks above.
  • The troubleshooting manual’s list for 29, written for technicians and service professionals only (AP21822 tech manual, p. 7). The first item is the protection plug on the drain connection at the bottom of the unit, which may not have been removed. The others are a blockage inside or outside the drain line, a pinched line, and a “P” trap, which the drain line does not need and which the manual says to remove (AP21822 tech manual, p. 43).
  • Do not run the heater without the condensate drain connected and routed to an external neutralizer or to a drain that can handle corrosive condensate (RTGH-3 manual, p. 64).
  • Changes to the drain line follow the installation rules: PVC, CPVC or flexible tube only, and no direct connection to the sewer (RTGH-3 manual, p. 41).

Notes for different models

Code 29 belongs to the condensing RTGH-3. The RTG-3 chart does not list it (RTG-3 Use and Care Manual, p. 77), and the RTG-R-3 Troubleshooting Manual has no section for it. AP21822 covers both RTGH-3 and RTG-3 models, but labels the water level electrode “FOR CONDENSING MODEL ONLY” (AP21822 tech manual, p. 19).

The RTG-3 and RTG-R-3 manuals describe a condensate trap for direct-vent models that connects to the vent. Owners are asked to inspect it regularly to make sure it holds enough water and drains properly (RTG-3 manual, p. 66; RTG-R-3 Use and Care Manual, p. 63).

IKONIC heaters show A029 for a blocked condensate line and send it to a dealer or qualified service technician (IKONIC Use and Care Manual, p. 107). Their manual asks owners to inspect the condensate drain line on a regular basis and to check the neutralizer medium periodically (IKONIC Use and Care Manual, p. 94).

Related codes: A029, 17. All Rheem codes

Rheem tankless code 61 (blower motor): what to check

Checked

Rheem display

61

“Faulty blower motor.”

Technician

Printed on 4 model series · 6 documents

RTGH-3, RTG-3, RTG-R-3, Ruud Mid-Efficiency · RTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 51; AP24838 tech manual p. 44; AP18000-2 manual p. 26

Troubleshooting manual name: "Blower motor speed incorrect for combustion": the RPM signal is incorrect after the fan starts (AP21822 tech manual, p. 51). The Ruud Tankless Mid-Efficiency chart prints this row as "61 or 99" (AP18000-2 manual, p. 26).

Short answer On Rheem RTGH-3, RTG-3 and RTG-R-3 heaters, code 61 means a faulty blower motor: the fan's speed signal is wrong after it starts. Reset the heater; if 61 stays, call a dealer or qualified service technician. See what to check

What it means

The heater checks the fan’s RPM signal after the fan starts to run. If the signal is incorrect, it shows 61 (RTGH-3 and RTG-3 Troubleshooting Manual, AP21822, p. 51; RTG-R-3 Troubleshooting Manual, AP24838, p. 44). All three owner charts send 61 to a dealer or qualified service technician (RTGH-3 Use and Care Manual, p. 75; RTG-3 Use and Care Manual, p. 77; RTG-R-3 Use and Care Manual, p. 74).

A fan that keeps turning for a while after you close the hot tap is normal. Rheem calls it the post-purge cycle, which clears flue gases (RTGH-3 manual, p. 73; RTG-3 manual, p. 75; RTG-R-3 manual, p. 72).

Check these first

The charts give no owner remedy for 61 beyond the service call. The reset sequence that applies to every code is the only owner step.

  1. Close all hot water taps. Turn the heater off with the POWER ON/OFF button on the remote control, wait about 5 minutes, turn it back on, then open a hot tap and check the display (RTGH-3 manual, p. 74; RTG-3 manual, p. 76; RTG-R-3 manual, p. 73).
  2. If 61 is still shown, close the tap, turn the heater off, unplug it for about 30 seconds, plug it back in and restart (RTGH-3 manual, p. 74).
  3. If 61 is still shown, turn the heater off, write down the code and call for service (RTGH-3 manual, p. 74). Rheem directs repairs to your installer, plumbing contractor or licensed service agent, and lists its Manufacturer National Service Department at 1-866-720-2076 if the problem is not solved (RTGH-3 manual, p. 75).

When to call a licensed technician

  • Every case of 61 that the reset does not clear.
  • Anything that means opening the heater. Rheem tells owners not to disassemble it (RTGH-3 manual, p. 8) and says only a qualified service technician should remove the front cover (RTGH-3 manual, p. 49); removing the front cover panel exposes live electricity (RTGH-3 manual, p. 65).
  • The troubleshooting manual’s checks for 61 are written for technicians and service professionals only (AP21822 tech manual, p. 7). Its flowchart includes DC voltage measurements, with a window of 144–192 V DC in AP21822 (AP21822 tech manual, p. 51) and 145–195 V DC in AP24838 (AP24838 tech manual, p. 44).
  • The same manual sends technicians to the 61 section from code 10, which means the blower is not creating enough ventilation or the heater ran before the vent was installed (AP21822 tech manual, p. 37). Code 79 is a separate blower code for motor current (AP21822 tech manual, p. 58).

Notes for different models

The chart for Ruud Tankless Mid-Efficiency heaters prints its blower row as “61 or 99” (Tankless Water Heater Use and Care Manual AP18000-2, p. 26). On the -3 heaters, 99 is a venting code instead.

IKONIC heaters show A061 for a faulty blower motor, with the same remedy (IKONIC Use and Care Manual, p. 107).

Related codes: 79, 10. All Rheem codes

Rheem tankless code 90 (blocked vent or air intake): what to check

Checked

Rheem display

90

“Air intake or vent exhaust opening may be blocked.”

Owner checks, then technician

RTGH-3, RTG-3, RTG-R-3 · RTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 61; AP24838 tech manual p. 56

The charts print one row for "90 or 99", with a second cause: "The vent pipes on the vent termination may not be connected properly." The troubleshooting manual says 90 occurs before the unit goes into ignition and 99 after it shuts down (AP21822 tech manual, p. 61).

Short answer On Rheem RTGH-3, RTG-3 and RTG-R-3 heaters, code 90 means the air intake or vent exhaust opening may be blocked (found before ignition). With the heater off, clear both openings outside, then restart; if 90 stays, call for service. See what to check

What it means

Code 90 means the heater found a blockage in its venting before it went into ignition. The troubleshooting manual says the heater checks for a blockage during its pre-purge and post-purge cycles, that the same code appears if the heater was run before the vent was installed, and that 90 occurs before ignition while 99 occurs after the unit shuts down (RTGH-3 and RTG-3 Troubleshooting Manual, AP21822, p. 61; RTG-R-3 Troubleshooting Manual, AP24838, p. 56).

The owner charts print 90 and 99 in one row with two causes. A blocked air intake or vent exhaust opening is for the owner to clear. Vent pipes not connected properly at the termination go to a dealer or qualified service technician (RTGH-3 Use and Care Manual, p. 75; RTG-3 Use and Care Manual, p. 77; RTG-R-3 Use and Care Manual, p. 74).

Check these first

  1. Close all hot water taps. Turn the heater off with the POWER ON/OFF button on the remote control, wait about 5 minutes, turn it back on, then open a hot tap and check the display (RTGH-3 manual, p. 74; RTG-3 manual, p. 76; RTG-R-3 manual, p. 73).
  2. If 90 is still shown, close the tap, turn the heater off, unplug it for about 30 seconds and plug it back in. Keep the heater turned off while you check the venting (RTGH-3 manual, pp. 66, 74).
  3. Go outside to where the air intake and vent exhaust end, and remove anything blocking them. Leave at least 12 in. (30 cm) between the air intake opening and any obstruction (RTGH-3 manual, pp. 66, 75; RTG-3 manual, p. 68; RTG-R-3 manual, p. 65).
  4. On RTGH-3 heaters, the owner maintenance list also includes a visual check of the vent screens, removing any debris or blockage (RTGH-3 manual, p. 68).
  5. Restart the heater, open a hot tap and check the display. If 90 is still shown, turn the heater off, write down the code and call for service (RTGH-3 manual, p. 74).

Do not run the heater if the vent system shows signs of leaking exhaust (RTGH-3 manual, p. 64; RTG-3 manual, p. 66; RTG-R-3 manual, p. 63).

When to call a licensed technician

  • Vent pipes that are loose or not connected properly at the termination. The chart sends this to a dealer or qualified service technician (RTGH-3 manual, p. 75).
  • Code 90 that returns with the openings clear.
  • Any change to the vent run. All three manuals require venting to follow national and local codes and the vent manufacturer’s instructions, and forbid venting through a chimney (RTGH-3 manual, p. 20; RTG-3 manual, p. 21; RTG-R-3 manual, p. 21).
  • RTGH-3 vent limits: only 2 or 3 in. pipe of approved materials (RTGH-3 manual, p. 20). With no elbows, the longest equivalent run is 60 ft (18.3 m) of 2 in. pipe or 150 ft (45.7 m) of 3 in. pipe; a standard 90° elbow counts as 6 ft (1.83 m), and DIP switch settings depend on vent length (RTGH-3 manual, p. 21).
  • RTG-3 and RTG-R-3 direct-vent limits: 3 in./5 in. (7.6 cm/12.7 cm) UL-approved Category III coaxial stainless steel vent pipe, or concentric vent pipe approved by the water heater manufacturer (RTG-3 manual, p. 21; RTG-R-3 manual, p. 21). With no elbows, the longest equivalent run is 43 ft (13.1 m) (RTG-3 manual, p. 22; RTG-R-3 manual, p. 22).
  • The yearly vent inspection. The RTGH-3 manual says the venting system should be inspected annually to make sure every section is secure and airtight, and that qualified service personnel can advise (RTGH-3 manual, p. 64). The RTG-3 and RTG-R-3 manuals assign that inspection to a qualified service technician (RTG-3 manual, p. 66; RTG-R-3 manual, p. 63).

The manuals warn never to run the heater unless it is properly vented (RTGH-3 manual, p. 3; RTG-3 manual, p. 21; RTG-R-3 manual, p. 21).

Notes for different models

Code 99 shares this chart row. Rheem’s troubleshooting manual also lists 99 as a “hard lockout” whose reset is done behind the front cover (AP21822 tech manual, p. 61).

IKONIC heaters show A090, and their chart adds a third cause, “Blocked vent termination or inlet air filter.”, with a call to a dealer or qualified service technician (IKONIC Use and Care Manual, p. 107). IKONIC models have an inlet air filter that Rheem recommends inspecting and cleaning once a year (IKONIC Use and Care Manual, p. 97). The RTGH-3, RTG-3 and RTG-R-3 manuals give owners no air filter procedure.

On Ruud Tankless Mid-Efficiency heaters the chart uses 05 for a blocked air intake or vent, and 99 for a faulty blower motor (Tankless Water Heater Use and Care Manual AP18000-2, p. 26).

Related codes: 99, 10, 14. All Rheem codes

Rheem tankless code 99 (vent blockage after shutdown): what to check

Checked

Rheem display

99

“Air intake or vent exhaust opening may be blocked.”

Owner checks, then technician

RTGH-3, RTG-3, RTG-R-3 · RTGH-3 manual p. 75; RTG-3 manual p. 77; RTG-R-3 manual p. 74; AP21822 tech manual p. 61; AP24838 tech manual p. 56

Same chart row as 90 ("90 or 99"). The troubleshooting manual says 99 occurs after the unit shuts down and lists it with 10 and 13 as a "hard lockout" whose reset starts with removing the front cover (AP21822 tech manual, p. 61). Ruud Tankless Mid-Efficiency heaters use 99 for something else: their chart prints "61 or 99" as "Faulty blower motor.", with a call to a dealer or qualified service technician (AP18000-2 manual, p. 26).

Short answer On Rheem RTGH-3, RTG-3 and RTG-R-3 heaters, code 99 means the air intake or vent exhaust opening may be blocked: clear both openings outside, restart, and call for service if 99 stays. Ruud Mid-Efficiency heaters use 99 for a faulty blower motor. See what to check

What it means

Code 99 is the after-shutdown version of 90. Rheem’s troubleshooting manual says the heater checks for a blockage in the venting during its pre-purge and post-purge cycles, and that 99 occurs after the unit shuts down, while 90 occurs before ignition (RTGH-3 and RTG-3 Troubleshooting Manual, AP21822, p. 61; RTG-R-3 Troubleshooting Manual, AP24838, p. 56). In the owner charts, 90 and 99 share one row: the owner clears a blocked air intake or vent exhaust opening, and vent pipes not connected properly at the termination go to a dealer or qualified service technician (RTGH-3 Use and Care Manual, p. 75; RTG-3 Use and Care Manual, p. 77; RTG-R-3 Use and Care Manual, p. 74).

The troubleshooting manual also lists 99, with 10 and 13, as a “hard lockout”. Its reset procedure starts with turning the remote off, removing the front cover and setting DIP switches on the control board (AP21822 tech manual, p. 61). The Use and Care manual says only a qualified service technician should remove the front cover (RTGH-3 manual, p. 49).

Check these first

  1. Close all hot water taps. Turn the heater off with the POWER ON/OFF button on the remote control, wait about 5 minutes, turn it back on, then open a hot tap and check the display (RTGH-3 manual, p. 74; RTG-3 manual, p. 76; RTG-R-3 manual, p. 73).
  2. If 99 is still shown, close the tap, turn the heater off, unplug it for about 30 seconds and plug it back in. Keep the heater turned off while you check the venting (RTGH-3 manual, pp. 66, 74).
  3. Outside, remove anything blocking the air intake or the vent exhaust. Leave at least 12 in. (30 cm) between the air intake opening and any obstruction (RTGH-3 manual, pp. 66, 75; RTG-3 manual, p. 68; RTG-R-3 manual, p. 65).
  4. Restart the heater, open a hot tap and check the display. If 99 is still shown, turn the heater off, write down the code and call for service (RTGH-3 manual, p. 74). The Use and Care manuals do not say whether their reset sequence clears a hard lockout.

Do not run the heater if the vent system shows signs of leaking exhaust (RTGH-3 manual, p. 64; RTG-3 manual, p. 66; RTG-R-3 manual, p. 63).

When to call a licensed technician

  • Code 99 that stays after the openings are clear and the heater has been unplugged. The hard lockout reset is done behind the front cover, on the control board (AP21822 tech manual, p. 61).
  • Vent pipes that are loose or not connected properly at the termination (RTGH-3 manual, p. 75).
  • Any work on the vent run. The vent pipe and its length limits differ by series: RTGH-3 uses 2 or 3 in. pipe (RTGH-3 manual, pp. 20–21), RTG-3 and RTG-R-3 direct-vent models use 3 in./5 in. Category III coaxial stainless steel or manufacturer-approved concentric vent pipe (RTG-3 manual, pp. 21–22; RTG-R-3 manual, pp. 21–22).
  • The yearly vent inspection (RTGH-3 manual, p. 64; RTG-3 manual, p. 66; RTG-R-3 manual, p. 63).

Notes for different models

On Ruud Tankless Mid-Efficiency heaters, 99 means something else. Their chart prints it with 61 as a faulty blower motor and sends it to a dealer or qualified service technician; the venting row on that chart is 05 (Tankless Water Heater Use and Care Manual AP18000-2, p. 26). On those heaters the chart’s answer to 99 is a service call, not the venting checks above.

IKONIC heaters report a venting blockage as A090 (IKONIC Use and Care Manual, p. 107).

Related codes: 90, 10, 61. All Rheem codes

How to read a Rheem code

On RTGH-3, RTG-3 and RTG-R-3 heaters the code appears in the LED display of the remote control (RTGH-3 Use and Care Manual, p. 74). Condensing and non-condensing indoor models also show it on a built-in controller (RTGH-3 and RTG-3 Troubleshooting Manual, AP21822, p. 21). Most codes are two digits; 1L and P1 include a letter.

The Service Error Code Chart in each Use and Care manual lists only some of the codes (RTGH-3 manual, p. 75; RTG-3 Use and Care Manual, p. 77; RTG-R-3 Use and Care Manual, p. 74). The rest come from Rheem’s troubleshooting manuals, written for technicians and service professionals only (AP21822 tech manual, p. 7).

IKONIC heaters show codes such as A011 or T111 on the LCD of the user interface (IKONIC Use and Care Manual, pp. 106–107). On ThermaForce heaters (RTGH-L199i; both names are from rheem.com, not the manuals), fault codes such as F004 flash on the main display (I&O manual 84160404, p. 5-5).

Clearing a code

The RTGH-3, RTG-3 and RTG-R-3 manuals print the same sequence (RTGH-3 manual, p. 74; RTG-3 manual, p. 76; RTG-R-3 manual, p. 73):

  1. Close all hot water taps. Turn the heater off with POWER ON/OFF on the remote, wait about 5 minutes, turn it on and open a hot tap.
  2. If the code remains, turn the heater off, unplug it for about 30 seconds, plug it back in, follow the chart for that code and restart.
  3. If the code is still shown, turn the heater off, write the code down and call for service. If the code is not in the chart, turn the heater off immediately and call.

The troubleshooting manual calls 10, 13 and 99 “hard lockouts” and resets them with the front cover off (AP21822 tech manual, p. 61). Only a qualified service technician should remove that cover (RTGH-3 manual, p. 49).

IKONIC heaters clear codes from the SERVICE menu with “Clear Alarms?” (IKONIC Use and Care Manual, p. 106). For ThermaForce, the installation manual resets fault codes by touching the wrench for 2 seconds after the cause is resolved (I&O manual 84160404, p. 5-5). The user’s manual gives owners that reset only for a blocked vent that is easily accessible and removable; otherwise it says to contact a qualified service agency (User’s manual 84161404, p. 4).

When to stop and call a professional

If you smell gas, follow the block on the manual’s cover; its last step is not to return home until the gas supplier or fire department authorizes it (RTGH-3 manual, p. 1). Do not try to find a gas leak yourself (RTGH-3 manual, p. 5).

Owners should not repair electrical wiring, gas piping, the remote control, burners, vent connectors or other safety devices (RTGH-3 manual, p. 5), or disassemble the heater (RTGH-3 manual, p. 8). Turn off the manual gas shut-off valve if the heater has been through overheating, fire, flood or physical damage, or if the gas does not shut off (RTGH-3 manual, p. 5).

Hard-wiring is for a qualified electrician (RTGH-3 manual, p. 47). The RTGH-3 (Rev 06), RTG-3 (Rev 06), RTG-R-3 and IKONIC manuals recommend not connecting the heater to a GFCI or AFCI circuit (RTGH-3 manual, p. 47; RTG-3 manual, p. 44; RTG-R-3 manual, p. 44; IKONIC Use and Care Manual, p. 69). The Rev 04 manuals for ECOH-3 and ECO-3 models, the RTGH Easy Installation Guide and the Ruud AP18000-2 manual say not to (ECOH-3 Use and Care Manual, p. 47; ECO-3 Use and Care Manual, p. 44; RTGH EZ guide, p. 5; AP18000-2 manual, p. 55).

Questions, adjustments and repairs go to your installer, plumbing contractor or licensed service agent. If the problem is still not solved, Rheem lists its Manufacturer National Service Department at 1-866-720-2076 (RTGH-3 manual, p. 75).

See also

Other tankless water heaters: Navien, Noritz, Rinnai

Rheem is a trademark of its owner. How House Works is not affiliated with or endorsed by Rheem.

Sources

16 documents
  1. Rheem Manufacturing Company. RTGH-3 Use and Care Manual. AP21820 Rev 06, no printed date; cover title: Super High Efficiency Condensing Tankless Water Heater Use and Care Manual; the same file is posted for Ruud RUTGH models; p. 1 is the unnumbered cover. Accessed Oct 12, 2026.
  2. Rheem Manufacturing Company. ECOH-3 Use and Care Manual. AP21820 Rev 04, no printed date; cover title: Super High Efficiency Condensing Tankless Water Heater Use and Care Manual; Rev 04 of the RTGH-3 manual, linked from the ECOH-3 product page. Accessed Oct 12, 2026.
  3. Rheem Manufacturing Company. RTG-3 Use and Care Manual. AP22009 Rev 06, no printed date; cover title: High-Efficiency Non-Condensing Tankless Water Heater Use and Care Manual; the same file is posted for Ruud RUTG models. Accessed Oct 12, 2026.
  4. Rheem Manufacturing Company. ECO-3 Use and Care Manual. AP22009 Rev 04, no printed date; cover title: High-Efficiency Non-Condensing Tankless Water Heater Use and Care Manual; Rev 04 of the RTG-3 manual, linked from the ECO-3 product pages. Accessed Oct 12, 2026.
  5. Rheem Manufacturing Company. RTG-R-3 Use and Care Manual. AP23962 Rev 02, no printed date; cover title: High-Efficiency Non-Condensing Tankless Water Heater with Recirculation Use and Care Manual; the same file is posted for Ruud RUTG-R models. Accessed Oct 12, 2026.
  6. Rheem Manufacturing Company. RTGH Tankless Easy Installation Guide. AP23365, no revision or date printed; no page numbers printed, pages given are PDF pages. Accessed Oct 12, 2026.
  7. Rheem Manufacturing Company. RTG Tankless Easy Installation Guide. AP23366, no revision or date printed; no page numbers printed, p. 2 is the PDF page. Accessed Oct 12, 2026.
  8. Rheem Manufacturing Company. RTG-R Tankless Easy Installation Guide. AP23964 Rev 00, print-file stamp 7/7/25; no page numbers printed, p. 2 is the PDF page. Accessed Oct 12, 2026.
  9. Rheem Manufacturing Company. RTGH-3 and RTG-3 Troubleshooting Manual. AP21822 Rev 02, no issue date printed; cover title: High and Super High Efficiency Tankless Water Heater Troubleshooting Manual; written for technicians and service professionals only (p. 7). Accessed Oct 12, 2026.
  10. Rheem Manufacturing Company. RTG-R-3 Troubleshooting Manual. AP24838 Rev 01, no issue date printed; cover title: High Efficiency Tankless Water Heater with Recirculation Troubleshooting Manual; written for technicians and service professionals only (p. 6). Accessed Oct 12, 2026.
  11. Rheem Manufacturing Company. IKONIC Use and Care Manual. AP22745 Rev 07, no printed date; cover title: Condensing Tankless Water Heater Use and Care Manual; Ruud's S and SR Series pages post Rev 06. Accessed Oct 12, 2026.
  12. Rheem Manufacturing Company. IKONIC Technical Training and Service Manual. AP23209 Rev 03, no printed date; written for technicians and service professionals only (p. 4). Accessed Oct 12, 2026.
  13. Rheem Sales Co. / IBC Technologies. User's Information Manual 84161404. Document 84161404, May 2023; cover title: User's Information Manual, High Efficiency Condensing Tankless Water Heater, 199,000 Btu/hr Model (Natural Gas or Propane); the manual does not print the names ThermaForce, RTGH-L199i or L-Series, which come from the rheem.com and ruud.com product pages that post it (2026-10-12). Accessed Oct 12, 2026.
  14. Rheem Sales Co. / IBC Technologies. Installation and Operating Instructions 84160404. Document 84160404, May 2023; cover title: Installation and Operating Instructions, High Efficiency Condensing Tankless Water Heater; page numbers are printed by section (p. 5-5 is PDF page 67); the manual does not print the names ThermaForce, RTGH-L199i or L-Series, which come from the rheem.com and ruud.com product pages that post it (2026-10-12). Accessed Oct 12, 2026.
  15. Rheem Sales Co. / IBC Technologies. Controller Manual 84162404. Document 84162404, May 2023; cover title: Controller Manual, Tankless Water Heater Controller; page numbers are printed by section (p. 1-40 is PDF page 44); the manual does not print the names ThermaForce, RTGH-L199i or L-Series, which come from the rheem.com and ruud.com product pages that post it (2026-10-12). Accessed Oct 12, 2026.
  16. Rheem Manufacturing Company (posted on ruud.com). Tankless Water Heater Use and Care Manual AP18000-2. AP18000-2 Rev 03, no printed date; cover title: Tankless Water Heater Use and Care Manual, Noncondensing 199,900 Btu/h, 180,000 Btu/h, and 150,000 Btu/h Models; the manual prints no model numbers and no -3 suffix; ruud.com posts it on its Tankless Mid-Efficiency 70, 84 and 95 product pages (2026-10-12). Accessed Oct 12, 2026.