Navien boiler error codes (combi and heating-only boilers)
56 codes for NCB-H, NCB700, NFC-H, NFB-H, NHB-H, NFB-C, NFB700-C, NCB-E, NFC, NFB, NHB, each with the wording and source from Navien User's Information Manuals and Installation & Operation manuals.
How House Works EditorialChecked against 19 sources,
- Prepared by
- How House Works Editorial
- How it is checked
- Methodology
- Page
- HHW · ERROR-CODES · NAVIEN-BOILER
- Based on
- Navien User's Information Manuals and Installation & Operation manuals
Meanings are quoted from Navien User's Information Manuals and Installation & Operation manuals. The "Who" column is our reading of the remedy in those documents: whether an owner can do the first checks, or the fix belongs to a licensed technician.
Codes with step-by-step checks
All Navien boilers codes
| Code | Meaning | Who | Series | Source |
|---|---|---|---|---|
| E001 | “Heat Exchanger Overheat” What to check | Owner checks, then technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E001 | “Heatexchanger over temperature” What to check | Owner checks, then technician | NFC-H, NFC | NFC-H installation manual (March 2021) p. 127; NFC installation manual p. 101 |
| E001 | “Heat exchanger over temperature” What to check | Owner checks, then technician | NFB-C, NFB700-C, NFB, NHB | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20; NHB user's manual p. 22 |
| E003 | “Ignition Failure” What to check | Owner checks, then technician | 11 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H, NFB-C, NFB700-C, NCB-E, NFC, NFB, NHB | 11 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NCB-E user's manual p. 22; NFC installation manual p. 101; NFB user's manual p. 20; NHB user's manual p. 22 |
| E004 | “False Flame” | Owner checks, then technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E004 | “False flame detection” | Owner checks, then technician | 7 seriesNFC-H, NFB-C, NFB700-C, NCB-E, NFC, NFB, NHB | 7 documentsNFC-H installation manual (March 2021) p. 127; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NCB-E user's manual p. 22; NFC installation manual p. 101; NFB user's manual p. 20; NHB user's manual p. 22 |
| E012 | “Flame Loss” What to check | Owner checks, then technician | 11 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H, NFB-C, NFB700-C, NCB-E, NFC, NFB, NHB | 11 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NCB-E user's manual p. 22; NFC installation manual p. 101; NFB user's manual p. 20; NHB user's manual p. 22 |
| E016 | “Heat Exchanger Overheat” | Owner checks, then technician | 8 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H, NFB-C, NFB700-C, NHB | 8 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NHB user's manual p. 22 |
| E016 | “Overheating of heat exchanger” | Owner checks, then technician | NFC-H, NCB-E, NFC | NFC-H installation manual (March 2021) p. 127; NCB-E user's manual p. 22; NFC installation manual p. 101 |
| E016 | “Heat exchanger overheating” | Owner checks, then technician | NFB | NFB user's manual p. 20 |
| E020 | “Abnormal Gas Control Valve” | Technician | NCB-H, NCB700 | NCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136 |
| E020 | “Abnormal operation: gas valve” | Technician | NFB700-C | NFB700-C installation manual (July 2026) p. 119 |
| E030 | “Exhaust Overheat” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E030 | “Abnormal exhaust temperature” | Technician | NFC-H, NCB-E, NFC | NFC-H installation manual (March 2021) p. 127; NCB-E user's manual p. 22; NFC installation manual p. 101 |
| E030 | “Abnormal operation: exhaust temperature” | Technician | NFB-C, NFB700-C, NFB, NHB | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20; NHB user's manual p. 22 |
| E031 | “Burner Overheat” | Technician | NCB-H, NFC-H, NFB-H | NCB-H user's manual (January 2025) p. 25; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23 |
| E031 | “Overheating of burner” | Technician | NFC-H, NFC | NFC-H installation manual (March 2021) p. 127; NFC installation manual p. 101 |
| E031 | “Burner overheating” | Technician | NFB-C, NFB700-C, NFB | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20 |
| E046 | “Heat Exchanger Thermistor” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E046 | “Abnormal operation: heat exchanger overheating sensor” | Technician | NFC-H, NFB-C, NFB, NHB | NFC-H installation manual (March 2021) p. 127; NFB-C user's manual (April 2024) p. 19; NFB user's manual p. 20; NHB user's manual p. 22 |
| E046 | “Abnormal operation: limit control” | Technician | NCB-E, NFC | NCB-E user's manual p. 22; NFC installation manual p. 101 |
| E047 | “Exhaust Thermistor” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E047 | “Abnormal operation: exhaust thermostat” | Technician | 7 seriesNFC-H, NFB-C, NFB700-C, NCB-E, NFC, NFB, NHB | 7 documentsNFC-H installation manual (March 2021) p. 127; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NCB-E user's manual p. 22; NFC installation manual p. 101; NFB user's manual p. 20; NHB user's manual p. 22 |
| E059 | “Abnormal operation: overheat temperature sensor” | Technician | NFB700-C | NFB700-C installation manual (July 2026) p. 119 |
| E060 | “Abnormal Dual Venturi” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E060 | “Abnormal operation: dual venturi” | Technician | 7 seriesNFC-H, NFB-C, NFB700-C, NCB-E, NFC, NFB, NHB | 7 documentsNFC-H installation manual (March 2021) p. 127; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NCB-E user's manual p. 22; NFC installation manual p. 101; NFB user's manual p. 20; NHB user's manual p. 22 |
| E109 | “Abnormal Fan Motor” What to check | Owner checks, then technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E109 | “Abnormal operation: fan motor” What to check | Owner checks, then technician | 7 seriesNFC-H, NFB-C, NFB700-C, NCB-E, NFC, NFB, NHB | 7 documentsNFC-H installation manual (March 2021) p. 127; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NCB-E user's manual p. 22; NFC installation manual p. 101; NFB user's manual p. 20; NHB user's manual p. 22 |
| E110 | “Exhaust Blockage” What to check | Owner checks, then technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E110 | “Abnormal air pressure” What to check | Owner checks, then technician | NFC-H, NCB-E, NFC | NFC-H installation manual (March 2021) p. 127; NCB-E user's manual p. 22; NFC installation manual p. 101 |
| E110 | “Exhaust vent closed” What to check | Owner checks, then technician | NFB-C, NFB, NHB | NFB-C user's manual (April 2024) p. 19; NFB user's manual p. 20; NHB user's manual p. 22 |
| E110 | “Exhaust vent blocked” What to check | Owner checks, then technician | NFB700-C | NFB700-C installation manual (July 2026) p. 119 |
| E123 | “Abnormal Fan Motor Blower” | Technician | NCB-H, NCB700 | NCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136 |
| E123 | “Abnormal operation: fan output” | Technician | NFB700-C | NFB700-C installation manual (July 2026) p. 119 |
| E127 | “Abnormal operation: APS” | Technician | NFB-C, NFB700-C | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119 |
| E205 | “Heating Supply Temp.Sensor” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E205 | “Abnormal operation: heating supply thermistor” | Technician | 5 seriesNFC-H, NFB-C, NFB700-C, NFB, NHB | 5 documentsNFC-H installation manual (March 2021) p. 127; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20; NHB user's manual p. 22 |
| E205 | “Heating supply thermistor open or short circuit” | Technician | NCB-E, NFC | NCB-E user's manual p. 22; NFC installation manual p. 101 |
| E218 | “Heating Return Temp.Sensor” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E218 | “Abnormal operation: heating return thermistor” | Technician | 5 seriesNFC-H, NFB-C, NFB700-C, NFB, NHB | 5 documentsNFC-H installation manual (March 2021) p. 127; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20; NHB user's manual p. 22 |
| E218 | “Heating return thermistor open or short circuit” | Technician | NCB-E, NFC | NCB-E user's manual p. 22; NFC installation manual p. 101 |
| E271 | “Temperature differential limit” | Technician | NHB | NHB user's manual p. 22 |
| E278 | “Ext. Supply Sensor Not Detected” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E278 | “Abnormal operation: system supply thermistor” | Technician | 6 seriesNFC-H, NFB-C, NFB700-C, NFC, NFB, NHB | 6 documentsNFC-H installation manual (March 2021) p. 127; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFC installation manual p. 101; NFB user's manual p. 20; NHB user's manual p. 22 |
| E279 | “Ext. Return Sensor Not Detected” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E279 | “Abnormal operation: system return thermistor” | Technician | 6 seriesNFC-H, NFB-C, NFB700-C, NFC, NFB, NHB | 6 documentsNFC-H installation manual (March 2021) p. 127; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFC installation manual p. 101; NFB user's manual p. 20; NHB user's manual p. 22 |
| E291 | “Return Temp. Exceeds Supply” | Technician | NFB-H, NHB-H | NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E291 | “Supply/Return inversion limit” | Technician | NFB-C, NFB700-C, NFB, NHB | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20; NHB user's manual p. 22 |
| E302 | “Low Water Pressure” What to check | Technician | 6 seriesNCB700, NFB-H, NHB-H, NFB-C, NFB, NHB | 6 documentsNCB700 installation manual (July 2026) p. 136; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119; NFB-C user's manual (April 2024) p. 19; NFB user's manual p. 20; NHB user's manual p. 22 |
| E351 | “Abnormal Auto Feeder Valve” What to check | Technician | NCB-H, NFC-H | NCB-H user's manual (January 2025) p. 25; NFC-H user's manual (April 2024) p. 24 |
| E351 | “Abnormal Auto feeder valve (make-up water)” What to check | Technician | NFC-H, NCB-E, NFC | NFC-H installation manual (March 2021) p. 127; NCB-E user's manual p. 22; NFC installation manual p. 101 |
| E352 | “High Water Pressure” | Technician | 10 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H, NFB-C, NCB-E, NFC, NFB, NHB | 10 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119; NFB-C user's manual (April 2024) p. 19; NCB-E user's manual p. 22; NFC installation manual p. 101; NFB user's manual p. 20; NHB user's manual p. 22 |
| E353 | “Water Pressure Sensor” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E353 | “Abnormal operation: water pressure sensor” | Technician | 6 seriesNFC-H, NFB-C, NCB-E, NFC, NFB, NHB | 6 documentsNFC-H installation manual (March 2021) p. 127; NFB-C user's manual (April 2024) p. 19; NCB-E user's manual p. 22; NFC installation manual p. 101; NFB user's manual p. 20; NHB user's manual p. 22 |
| E407 | “Dom.Hot Water Outlet Sensor” What to check | Technician | NCB-H, NCB700, NFC-H | NCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24 |
| E407 | “Hot water outlet: thermistor open or short circuit” What to check | Technician | NFC-H, NFC | NFC-H installation manual (March 2021) p. 127; NFC installation manual p. 101 |
| E407 | “Hot water outlet thermistor open or short circuit” What to check | Technician | NCB-E | NCB-E user's manual p. 22 |
| E421 | “Dom.Cold Water Inlet Sensor” | Technician | NCB-H, NCB700, NFC-H | NCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24 |
| E421 | “Cold water inlet: thermistor open or short circuit” | Technician | NFC-H, NFC | NFC-H installation manual (March 2021) p. 127; NFC installation manual p. 101 |
| E421 | “Cold water inlet thermistor open or short circuit” | Technician | NCB-E | NCB-E user's manual p. 22 |
| E434 | “Abnormal Water Adjust Valve” | Technician | NCB-H, NCB700, NFC-H | NCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24 |
| E434 | “Abnormal operation: water adjustment valve” | Technician | NFC-H, NFC | NFC-H installation manual (March 2021) p. 127; NFC installation manual p. 101 |
| E439 | “No Dom.Water Flow Detected” | Owner checks, then technician | NCB-H, NCB700, NFC-H | NCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 136; NFC-H user's manual (April 2024) p. 24 |
| E439 | “Abnormal operation: flow sensor” | Owner checks, then technician | NFC-H, NCB-E, NFC | NFC-H installation manual (March 2021) p. 127; NCB-E user's manual p. 22; NFC installation manual p. 101 |
| E441 | “Dom.Hot Water Outlet2 Sensor” | Technician | NCB-H, NCB700, NFC-H | NCB-H user's manual (January 2025) p. 25; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 24 |
| E441 | “Hot water outlet 2: thermistor open or short circuit” | Technician | NFC-H, NFC | NFC-H installation manual (March 2021) p. 127; NFC installation manual p. 101 |
| E445 | “Abnormal Mixing Valve” | Technician | NCB-H, NCB700, NFC-H | NCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 24 |
| E445 | “Abnormal operation: Bypass mixing valve” | Technician | NFC-H, NFC | NFC-H installation manual (March 2021) p. 127; NFC installation manual p. 101 |
| E480 | “DHW Tank Sensor Not Detected” | Technician | NFB-H, NHB-H | NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E480 | “Abnormal operation: DHW tank temperature sensor” | Technician | NFB-C, NFB700-C, NFB | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20 |
| E515 | “Abnormal PCB” What to check | Owner checks, then technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E515 | “Abnormal operation: PCB component” What to check | Owner checks, then technician | 5 seriesNFC-H, NFB-C, NFB700-C, NFB, NHB | 5 documentsNFC-H installation manual (March 2021) p. 127; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20; NHB user's manual p. 22 |
| E515 | “Abnormal operation: PCB” What to check | Owner checks, then technician | NCB-E, NFC | NCB-E user's manual p. 22; NFC installation manual p. 101 |
| E517 | “Abnormal DIP Switch” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E517 | “Abnormal operation: Dip switch setting” | Technician | NFC-H, NCB-E, NFC | NFC-H installation manual (March 2021) p. 127; NCB-E user's manual p. 22; NFC installation manual p. 101 |
| E517 | “Abnormal operation: DIP switch setting (PCB)” | Technician | NFB-C, NFB700-C, NFB, NHB | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20; NHB user's manual p. 22 |
| E593 | “Abnormal Panel Key” | Technician | NCB700 | NCB700 installation manual (July 2026) p. 137 |
| E594 | “Abnormal EEPROM” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E594 | “Abnormal operation: EEPROM” | Technician | NFC-H, NCB-E, NFC | NFC-H installation manual (March 2021) p. 127; NCB-E user's manual p. 22; NFC installation manual p. 101 |
| E594 | “Abnormal operation: EEPROM (PCB)” | Technician | NFB-C, NFB700-C, NFB, NHB | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20; NHB user's manual p. 22 |
| E598 | “RTC communication abnormality” | Technician | NCB700 | NCB700 installation manual (July 2026) p. 137 |
| E615 | “Abnormal Memory” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E615 | “Abnormal operation: input and memory” | Technician | NFC-H, NCB-E, NFC | NFC-H installation manual (March 2021) p. 128; NCB-E user's manual p. 22; NFC installation manual p. 102 |
| E615 | “Abnormal operation: MCU” | Technician | NFB-C, NFB700-C, NFB, NHB | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20; NHB user's manual p. 22 |
| E706 | “Abnormal operation: air damper input” | Technician | NFB700-C | NFB700-C installation manual (July 2026) p. 119 |
| E736 | “Cascade Communication” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E736 | “Abnormal operation: cascade communication” | Technician | 7 seriesNFC-H, NFB-C, NFB700-C, NCB-E, NFC, NFB, NHB | 7 documentsNFC-H installation manual (March 2021) p. 128; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NCB-E user's manual p. 22; NFC installation manual p. 102; NFB user's manual p. 20; NHB user's manual p. 22 |
| E740 | “Outdoor Sensor Not Detected” | Owner checks, then technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 24; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E740 | “Abnormal operation: outdoor temperature sensor (appears only when the outdoor reset curve is enabled).” | Owner checks, then technician | NFC-H, NCB-E, NFC | NFC-H installation manual (March 2021) p. 128; NCB-E user's manual p. 22; NFC installation manual p. 102 |
| E740 | “Abnormal operation: outdoor temperature sensor” | Owner checks, then technician | NFB-C, NFB700-C, NFB, NHB | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 119; NFB user's manual p. 20; NHB user's manual p. 22 |
| E744 | “Abnormal operation: louver switch input” | Technician | NFB700-C | NFB700-C installation manual (July 2026) p. 119 |
| E761 | “Pump Aquastat Not Detected” | Owner checks, then technician | NCB-H, NCB700, NFC-H | NCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 25 |
| E761 | “Abnormal Operation: Pre-Heat Aquastat” | Owner checks, then technician | NFC-H, NFC | NFC-H installation manual (March 2021) p. 128; NFC installation manual p. 102 |
| E762 | “Vent Pipe Not Fully Inserted” What to check | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 25; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E762 | “Abnormal flue gas duct: Vent pipe not properly inserted” What to check | Technician | NFC-H | NFC-H installation manual (March 2021) p. 128 |
| E765 | “Abnormal external-pump” | Technician | NFB-C, NFB700-C | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 120 |
| E769 | “High Gas Pressure Switch” | Technician | NFB700-C | NFB700-C installation manual (July 2026) p. 120 |
| E772 | “Low Gas Pressure Switch” | Technician | NFB700-C | NFB700-C installation manual (July 2026) p. 120 |
| E773 | “Improper Gas Type Detected” | Technician | NCB-H, NCB700, NFC-H | NCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 25 |
| E773 | “Using the wrong gas” | Technician | NFC-H | NFC-H installation manual (March 2021) p. 128 |
| E774 | “Manual reset limit” | Technician | NFB-C, NFB700-C | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 120 |
| E775 | “Auto reset limit” | Technician | NFB-C, NFB700-C | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 120 |
| E777 | “Low Water Cutoff Activated” | Owner checks, then technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 25; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E777 | “Abnormal operation: LWCO limit (external device)” | Owner checks, then technician | NFC-H, NFB-C, NFB, NHB | NFC-H installation manual (March 2021) p. 128; NFB-C user's manual (April 2024) p. 19; NFB user's manual p. 20; NHB user's manual p. 22 |
| E777 | “Low Water Cut Off” | Owner checks, then technician | NFB700-C | NFB700-C installation manual (July 2026) p. 120 |
| E777 | “Abnormal operation: LWCO” | Owner checks, then technician | NCB-E | NCB-E user's manual p. 22 |
| E777 | “LWCO (service code: 7700) (external device)” | Owner checks, then technician | NFC | NFC installation manual p. 102 |
| E782 | “Front Panel Communication” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 25; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E782 | “Abnormal operation: panel communication” | Technician | NFC-H | NFC-H installation manual (March 2021) p. 128 |
| E782 | “Abnormal operation: boiler communication” | Technician | NFB-C, NFB700-C, NFB, NHB | NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 120; NFB user's manual p. 20; NHB user's manual p. 22 |
| E782 | “Abnormal operation: main panel communication” | Technician | NCB-E, NFC | NCB-E user's manual p. 22; NFC installation manual p. 102 |
| E784 | “Zone Controller Communication” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 25; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E784 | “Abnormal operation: zone controller communication (external device)” | Technician | 5 seriesNFC-H, NFB-C, NFB700-C, NFB, NHB | 5 documentsNFC-H installation manual (March 2021) p. 128; NFB-C user's manual (April 2024) p. 19; NFB700-C installation manual (July 2026) p. 120; NFB user's manual p. 20; NHB user's manual p. 22 |
| E784 | “Abnormal operation: zone controller communication” | Technician | NFC | NFC installation manual p. 102 |
| E786 | “Improper Front Panel” | Technician | NCB-H, NCB700, NFC-H | NCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H installation manual (March 2021) p. 128 |
| E786 | “Improper Front Panel Detected” | Technician | NFC-H, NFB-H, NHB-H | NFC-H user's manual (April 2024) p. 25; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E788 | “Incorrect Gas Type Setting” | Technician | 5 seriesNCB-H, NCB700, NFC-H, NFB-H, NHB-H | 5 documentsNCB-H user's manual (January 2025) p. 26; NCB700 installation manual (July 2026) p. 137; NFC-H user's manual (April 2024) p. 25; NFB-H user's manual (April 2024) p. 23; NHB-H installation manual (April 2026) p. 119 |
| E788 | “Abnormal Gas Setting” | Technician | NFC-H | NFC-H installation manual (March 2021) p. 128 |
| E788 | “Abnormal operation: Gas type settings” | Technician | NFB700-C | NFB700-C installation manual (July 2026) p. 120 |
What to check, code by code
Navien boiler error code E001: heat exchanger overheat
Checked
Boiler front panel display
E001
“Heat Exchanger Overheat”
Printed on 5 model series · 5 documents
Short answer E001 on a Navien boiler means heat exchanger overheat (NFB, NHB, NFB-C and NFB700-C tables: 'over temperature'). The NCB-H manual says to reset it once from the front panel; if it comes back, call an authorized technician or Navien Technical Support. See what to check
What it means
E001 is Navien’s heat exchanger overheat code. The NCB-H, NCB700, NFC-H, NFB-H and NHB-H tables word it “Heat Exchanger Overheat” (navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136; navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24). The NFB, NHB, NFB-C and NFB700-C tables say “Heat exchanger over temperature” (navien-nfb-um, p. 20; navien-nhb-um, p. 22; navien-nfb-c-um, p. 19; navien-nfb700-c-io, p. 119). The tables say nothing more about the condition. The NCB-E table has no E001 (navien-ncb-e-um, p. 22).
Do not mix it up with E016. In the NCB-H and NCB700 tables, E016 has the same words, “Heat Exchanger Overheat”, with different actions: turn off the system for at least 30 minutes and then restart it, and flush the heat exchanger (navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136). The NFC-H, NFB-H and NHB-H user’s manuals also use the same words for both codes (navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24). The manuals do not explain how the two codes differ, so go by the number on the display.
Check these first
For E001 the NCB-H user’s manual gives one action, “Reset the boiler from the front panel.” (navien-ncb-h-um-2501, p. 25). The NCB700 and NFC installation manuals give the same one (navien-ncb700-io, p. 136; navien-nfc-io, p. 101).
- Reset the boiler once: on the NCB-H, press Back on the front panel (navien-ncb-h-um-2501, p. 13). The NCB700 and NFC installation manuals also name the Back button (navien-ncb700-io, p. 116; navien-nfc-io, p. 87).
- If E001 comes back after the reset, the manual’s next step is an authorized technician, a licensed professional or Navien Technical Support at 1-800-519-8794 (navien-ncb-h-um-2501, p. 24).
- When you call, have the model number, serial number, date purchased, installation location and type, and the error code ready (navien-ncb-h-um-2501, p. 64).
On the NFC-H, NFB-H and NHB-H, the E001 row reads “Check for proper system flow.” (navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24). The manuals do not say who checks the flow or how, and they give the owner no procedure for it. The reset on these three is the Back button (navien-nfc-h-um-c, p. 13; navien-nfb-h-um, p. 13; navien-nhb-h-um, p. 14).
When to call a licensed technician
- E001 returns after one reset (navien-ncb-h-um-2501, p. 24).
- The system flow check from the NFC-H, NFB-H and NHB-H tables (navien-nfb-h-um, p. 23).
- Anything inside the boiler. Navien tells owners not to repair or replace any part unless the user’s manual specifically recommends it (navien-ncb-h-um-2501, p. 5).
- The seasonal inspection. A qualified technician should inspect the boiler at the beginning of every heating season and when there is a problem (navien-ncb-h-um-2501, p. 18).
Notes for different models
| Series and document | Wording | Action in the table | Source |
|---|---|---|---|
| NCB-H user’s manual, NCB700 installation manual | “Heat Exchanger Overheat” | “Reset the boiler from the front panel.” | navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136 |
| NFC-H, NFB-H, NHB-H user’s manuals | “Heat Exchanger Overheat” | “Check for proper system flow.” | navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24 |
| NFC-H installation manual (March 2021) | “Heatexchanger over temperature” (as printed) | “Manual RESET Auto RESET” | navien-nfc-h-io, p. 127 |
| NFC installation manual | “Heatexchanger over temperature” | “Reset the boiler from the front panel.” | navien-nfc-io, p. 101 |
| NFB, NHB, NFB-C user’s manuals, NFB700-C installation manual | “Heat exchanger over temperature” | “Auto reset/Manual reset/Power On reset” | navien-nfb-um, p. 20; navien-nhb-um, p. 22; navien-nfb-c-um, p. 19; navien-nfb700-c-io, p. 119 |
| NCB-E user’s manual | No E001 in the table | navien-ncb-e-um, p. 22 |
The manuals do not explain the “Auto reset”, “Manual reset” and “Power On reset” labels. The installation manuals describe “level 1” errors that clear automatically once the problem is resolved, but they do not say whether E001 is one of them (navien-ncb-h-io, p. 119).
E001 does not appear in the Navien tankless water heater tables used on this site. For those codes, see the Navien tankless table.
Related codes: E016, E046, E030. All Navien boilers codes
Navien boiler error code E003: ignition failure, what to check
Checked
Boiler front panel display
E003
“Ignition Failure”
Printed on 11 model series · 11 documents
Short answer On Navien boilers, E003 means ignition failure. If you smell gas, follow the gas safety steps on this page. On the NCB-H and NCB-E, check that the main gas supply valve is open and reset once; if E003 returns, call an authorized technician. See what to check
What it means
E003 is Navien’s ignition failure code. Every Navien boiler table used here has it, from the NCB-H combi to the NFB700-C, worded “Ignition Failure” or “Ignition failure” (navien-ncb-h-um-2501, p. 25; navien-nfb-um, p. 20; navien-nfb700-c-io, p. 119). These boilers have no pilot: an ignition device lights the burner automatically, and the user’s manual says not to try to light the burner by hand (navien-ncb-h-um-2501, p. 3).
The code tables do not say what stopped the ignition. A one-page Navien parts guide for the NCB-H says ignition failure can occur when there is a buildup of dirt or white powder (navien-ncb-h-emergency-kit, p. 1).
Check these first
The NCB-H user’s manual gives one action for E003 (navien-ncb-h-um-2501, p. 25), and the NCB-E manual gives the same one (navien-ncb-e-um, p. 22).
- If you smell gas, stop and follow the steps at the top of this page. Before operating the boiler, the manual says to smell all around the appliance area for gas, next to the floor as well, because some gas is heavier than air (navien-ncb-h-um-2501, p. 3).
- Make sure the main gas supply valve is open (navien-ncb-h-um-2501, p. 25).
- Reset the boiler once. On the NCB-H press Back on the front panel (navien-ncb-h-um-2501, p. 13); on the NCB-E press Reset (navien-ncb-e-um, p. 11).
- If E003 comes back, the manual’s next step is an authorized technician, a licensed professional or Navien Technical Support at 1-800-519-8794 (navien-ncb-h-um-2501, p. 24). Have the model number, serial number, date purchased, installation location and type, and the error code ready (navien-ncb-h-um-2501, p. 64).
The NFC-H, NFB-H and NHB-H user’s manuals word the E003 check as “Check gas supply valve and igniter.” and do not say who does it (navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24). They give the owner no procedure for the igniter, and they tell owners not to repair or replace any part of the boiler unless the manual specifically recommends it (navien-nfb-h-um, p. 5). The reset on these three is the Back button (navien-nfc-h-um-c, p. 13; navien-nfb-h-um, p. 13; navien-nhb-h-um, p. 14).
When to call a licensed technician
- E003 returns after the gas valve check and one reset (navien-ncb-h-um-2501, p. 24).
- Ignition failure that keeps happening on an NCB-H. Navien’s Emergency Kit Quick Guide describes a flame rod service for it. That work includes removing the igniter and fitting a new igniter gasket, and the guide warns that using the old gasket can cause gas leakage, which can cause severe personal injury or death (navien-ncb-h-emergency-kit, p. 1). The user’s manual has no igniter procedure for the owner and tells owners not to repair or replace any part unless it specifically recommends it (navien-ncb-h-um-2501, p. 5).
- Anything on the gas supply past the valve. The user’s manual cover says installation and service must be performed by a qualified installer, service agency or the gas supplier (navien-ncb-h-um-2501, p. 1).
Notes for different models
| Series and document | Wording | Action in the table | Source |
|---|---|---|---|
| NCB-H user’s manual, NCB700 installation manual | “Ignition Failure” | “Ensure that the main gas supply valve is open.” | navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136 |
| NCB-E user’s manual, NFC installation manual | “Ignition failure” | “Ensure that the main gas supply valve is open.” | navien-ncb-e-um, p. 22; navien-nfc-io, p. 101 |
| NFC-H, NFB-H, NHB-H user’s manuals | “Ignition Failure” | “Check gas supply valve and igniter.” | navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24 |
| NFC-H installation manual (March 2021) | “Ignition failure” | “Manual RESET” | navien-nfc-h-io, p. 127 |
| NFB, NHB, NFB-C user’s manuals, NFB700-C installation manual | “Ignition failure” | “Manual reset/Power On reset” | navien-nfb-um, p. 20; navien-nhb-um, p. 22; navien-nfb-c-um, p. 19; navien-nfb700-c-io, p. 119 |
The manuals do not explain the labels “Manual RESET”, “Manual reset” and “Power On reset”. The reset buttons differ: Reset on the NHB (navien-nhb-um, p. 11), press and hold Reset on the NFB-C (navien-nfb-c-um, p. 10), Back on the NFB (navien-nfb-um, p. 10). The Emergency Kit Quick Guide quoted above is written for the NCB-H.
Navien’s NCB700 downloads page had no user’s manual on October 21, 2026, and the NFC has only its installation manual, so for these two the action above comes from the installation manual.
Navien’s tankless water heaters also have an E003, with a table of their own: see Navien tankless E003.
Related codes: E012, E004, E020. All Navien boilers codes
Navien boiler error code E012: flame loss, what to check
Checked
Boiler front panel display
E012
“Flame Loss”
Printed on 11 model series · 11 documents
Short answer On Navien boilers, E012 means flame loss. On the NCB-H and NCB-E the manual's steps are to clean the intake air filter with the power off and make sure the cord is properly grounded; if E012 returns after one reset, call an authorized technician. See what to check
What it means
E012 is Navien’s flame loss code. Every Navien boiler table used here has it, worded “Flame Loss” or “Flame loss” (navien-ncb-h-um-2501, p. 25; navien-nfb-um, p. 20; navien-nfb700-c-io, p. 119). The tables say nothing more about the condition, and the action that goes with it depends on the series.
Check these first
The NCB-H user’s manual gives two actions for E012: “Clean the intake air filter.” and “Ensure that the electrical cord is properly grounded.” (navien-ncb-h-um-2501, p. 25). The NCB-E manual gives the same two (navien-ncb-e-um, p. 22).
- Clean the intake air filter (navien-ncb-h-um-2501, p. 25). The procedure starts with the power off: press the Power button to turn the boiler off and disconnect its power supply before you unfasten the four latches and remove the front cover. The filter is at the top left, held by one screw; dust and rinse it under clean running water, let it dry completely, refit it and the cover, then reconnect the power (navien-ncb-h-um-2501, pp. 16–17). The E110 page lists the steps in full.
- Make sure the boiler’s electrical cord is properly grounded (navien-ncb-h-um-2501, p. 25). The manual does not say how to check this. Among its service options it lists a licensed professional for the affected system, for example an electrician (navien-ncb-h-um-2501, p. 64).
- Reset the boiler once. On the NCB-H press Back on the front panel (navien-ncb-h-um-2501, p. 13); on the NCB-E press Reset (navien-ncb-e-um, p. 11).
- If E012 comes back, the manual’s next step is an authorized technician, a licensed professional or Navien Technical Support at 1-800-519-8794 (navien-ncb-h-um-2501, p. 24).
On the NCB-E the filter procedure is different: three buckles hold the cover, and the filter is cleaned with a toothbrush and clean running water (navien-ncb-e-um, pp. 14–15).
On the NFC-H, NFB-H and NHB-H the E012 row reads “Check gas, venting and condensate trap.” and does not say who checks (navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24). The owner maintenance schedule in the same manuals is not tied to any code, but it does give the owner two related monthly items: a visual inspection of the vent piping for signs of leakage and blockage, and an inspection of the condensate trap and the PVC fittings (navien-nfc-h-um-c, p. 18; navien-nfb-h-um, p. 17; navien-nhb-h-um, p. 18). Cleaning the condensate trap is in the service technician’s section of those manuals (navien-nfc-h-um-c, p. 19; navien-nfb-h-um, p. 18; navien-nhb-h-um, p. 19).
When to call a licensed technician
- E012 returns after the filter, the cord check and one reset (navien-ncb-h-um-2501, p. 24).
- Anything on the gas supply. The user’s manual cover says installation and service must be performed by a qualified installer, service agency or the gas supplier (navien-ncb-h-um-2501, p. 1).
- Cleaning the condensate trap, which the manuals place in the service technician’s section (navien-nfb-h-um, p. 18).
- Anything inside the boiler beyond the air filter. Navien tells owners not to repair or replace any part unless the user’s manual specifically recommends it (navien-ncb-h-um-2501, p. 5).
Notes for different models
| Series and document | Wording | Action in the table | Source |
|---|---|---|---|
| NCB-H user’s manual, NCB700 installation manual | “Flame Loss” | “Clean the intake air filter.” and “Ensure that the electrical cord is properly grounded.” | navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136 |
| NCB-E user’s manual, NFC installation manual | “Flame loss” | The same two actions | navien-ncb-e-um, p. 22; navien-nfc-io, p. 101 |
| NFC-H, NFB-H, NHB-H user’s manuals | “Flame Loss” | “Check gas, venting and condensate trap.” | navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24 |
| NFC-H installation manual (March 2021) | “Flame loss” | “Manual RESET” | navien-nfc-h-io, p. 127 |
| NFB, NHB, NFB-C user’s manuals, NFB700-C installation manual | “Flame loss” | “Manual reset/Power On reset” | navien-nfb-um, p. 20; navien-nhb-um, p. 22; navien-nfb-c-um, p. 19; navien-nfb700-c-io, p. 119 |
The manuals do not explain the “Manual reset” and “Power On reset” labels. The NCB700 has no user’s manual on Navien’s downloads page (checked October 21, 2026), so its actions come from the installation manual.
Navien’s tankless water heaters also have an E012, with a table of their own: see Navien tankless E012.
Related codes: E003, E004, E110. All Navien boilers codes
Navien boiler error code E109: abnormal fan motor
Checked
Boiler front panel display
E109
“Abnormal Fan Motor”
Printed on 5 model series · 5 documents
Short answer On Navien boilers, E109 is 'abnormal fan motor'. On the NCB-H and NCB-E the one owner step is to clean the intake air filter with the power off; if E109 returns after one reset, call an authorized technician or Navien Technical Support. See what to check
What it means
E109 is Navien’s fan motor code. The NCB-H, NCB700, NFC-H, NFB-H and NHB-H tables call it “Abnormal Fan Motor” (navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136; navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24). The NCB-E, NFC, NFB, NHB, NFB-C and NFB700-C tables say “Abnormal operation: fan motor” (navien-ncb-e-um, p. 22; navien-nfc-io, p. 101; navien-nfb-um, p. 20; navien-nhb-um, p. 22; navien-nfb-c-um, p. 19; navien-nfb700-c-io, p. 119). The tables do not describe the fault further.
Check these first
The NCB-H user’s manual gives one action for E109, “Clean the intake air filter.” (navien-ncb-h-um-2501, p. 25). The NCB-E manual gives the same one (navien-ncb-e-um, p. 22), and so do the NCB700 and NFC installation manuals (navien-ncb700-io, p. 136; navien-nfc-io, p. 101).
- Clean the intake air filter (navien-ncb-h-um-2501, p. 25). The procedure starts with the power off: press the Power button to turn the boiler off and disconnect its power supply before you unfasten the four latches and remove the front cover. The filter is at the top left, held by one screw; dust and rinse it under clean running water, let it dry completely, refit it and the cover, then reconnect the power (navien-ncb-h-um-2501, pp. 16–17). The E110 page lists the steps in full. On the NCB-E, three buckles hold the cover and the filter is cleaned with a toothbrush and clean running water (navien-ncb-e-um, pp. 14–15).
- Reset the boiler once. On the NCB-H press Back on the front panel (navien-ncb-h-um-2501, p. 13); on the NCB-E press Reset (navien-ncb-e-um, p. 11).
- If E109 comes back, the manual’s next step is an authorized technician, a licensed professional or Navien Technical Support at 1-800-519-8794 (navien-ncb-h-um-2501, p. 24). Have the model number, serial number, date purchased, installation location and type, and the error code ready (navien-ncb-h-um-2501, p. 64).
On the NFC-H, NFB-H and NHB-H the E109 row reads “Check fan and venting.” and does not say who checks (navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24). These manuals give the owner no procedure for the fan, and they tell owners not to repair or replace any part unless the manual specifically recommends it (navien-nfb-h-um, p. 5). The owner maintenance schedule, which is not tied to any code, includes a monthly visual inspection of the vent piping for signs of leakage and blockage (navien-nfb-h-um, p. 17). The reset on these three is the Back button (navien-nfc-h-um-c, p. 13; navien-nfb-h-um, p. 13; navien-nhb-h-um, p. 14).
When to call a licensed technician
- E109 returns after a clean filter and one reset (navien-ncb-h-um-2501, p. 24).
- The fan check from the NFC-H, NFB-H and NHB-H tables (navien-nfb-h-um, p. 23).
- A vent or intake pipe that is damaged, separated at a joint, or shows corrosion, rusting or melting. Turn the boiler off and stop using it (navien-ncb-h-um-2501, p. 4).
- Anything inside the boiler beyond the air filter. Navien tells owners not to repair or replace any part unless the user’s manual specifically recommends it (navien-ncb-h-um-2501, p. 5).
Notes for different models
| Series and document | Wording | Action in the table | Source |
|---|---|---|---|
| NCB-H user’s manual, NCB700 installation manual | “Abnormal Fan Motor” | “Clean the intake air filter.” | navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136 |
| NCB-E user’s manual, NFC installation manual | “Abnormal operation: fan motor” | “Clean the intake air filter.” | navien-ncb-e-um, p. 22; navien-nfc-io, p. 101 |
| NFC-H, NFB-H, NHB-H user’s manuals | “Abnormal Fan Motor” | “Check fan and venting.” | navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24 |
| NFC-H installation manual (March 2021) | “Abnormal operation: fan motor” | “Manual RESET” | navien-nfc-h-io, p. 127 |
| NFB, NHB, NFB-C user’s manuals, NFB700-C installation manual | “Abnormal operation: fan motor” | “Manual reset/Power On reset” | navien-nfb-um, p. 20; navien-nhb-um, p. 22; navien-nfb-c-um, p. 19; navien-nfb700-c-io, p. 119 |
A separate code, E123, is “Abnormal Fan Motor Blower” in the January 2025 NCB-H user’s manual and the NCB700 installation manual, with the action “Contact technical support at 1-800-519-8794.” (navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136). The April 2024 NCB-H edition does not list E123 (navien-ncb-h-um-2404, pp. 25–26). On the NFB700-C, E123 is “Abnormal operation: fan output” (navien-nfb700-c-io, p. 119).
The manuals do not explain the “Manual reset” and “Power On reset” labels.
Navien’s tankless water heaters also have an E109, with a table of their own: see Navien tankless E109.
Related codes: E110, E123, E012. All Navien boilers codes
Navien boiler error code E110: exhaust blockage, what to check
Checked
Boiler front panel display
E110
“Exhaust Blockage”
Printed on 5 model series · 5 documents
Short answer On Navien NCB-H, NFC-H, NFB-H and NHB-H boilers, E110 is 'exhaust blockage'; other series word it differently, see the table below. Make sure the exhaust pipe is clear and clean the intake air filter with the power off; if it returns, call a technician. See what to check
What it means
On the NCB-H, NCB700, NFC-H, NFB-H and NHB-H, E110 is “Exhaust Blockage” (navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136; navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24). Other tables word it differently; see the notes at the end of this page.
The user’s manuals also name a cause on the intake side. If the air intake filter becomes clogged by dust or lint, the boiler stops operating and “Error Code 110” appears on the front panel display (navien-ncb-h-um-2501, p. 16). The NFC-H, NFB-H, NHB-H, NCB-E, NFB and NHB user’s manuals say the same (navien-nfc-h-um-c, p. 15; navien-nfb-h-um, p. 15; navien-nhb-h-um, p. 16; navien-ncb-e-um, p. 14; navien-nfb-um, p. 12; navien-nhb-um, p. 13).
Check these first
These steps follow the NCB-H user’s manual, whose E110 row gives two actions (navien-ncb-h-um-2501, p. 25). The NCB-E row gives the same two (navien-ncb-e-um, p. 22); its filter procedure is in the notes below.
- Make sure the exhaust pipe is free of obstructions (navien-ncb-h-um-2501, p. 25). The manual does not say how to check. Its owner maintenance schedule describes the monthly vent check as a visual inspection of the vent piping for signs of leakage and blockage (navien-ncb-h-um-2501, p. 18).
- While you look, check the pipes for damage. If any vent pipe, vent elbow or intake pipe is damaged, separated at a joint, or shows corrosion, rusting or melting, turn the boiler off and stop using it (navien-ncb-h-um-2501, p. 4).
- Clean the intake air filter (navien-ncb-h-um-2501, p. 25). The manual’s procedure starts with the power off: press the Power button to turn the boiler off and disconnect its power supply, then unfasten the four latches (two at the top, two at the bottom) and remove the front cover. The filter is at the top left, held by one screw. Pull it out, remove it from its plastic assembly, dust it and rinse it under clean running water, and let it dry completely. Refit the filter and its screw, replace the front cover, reconnect the power and turn the boiler on (navien-ncb-h-um-2501, pp. 16–17). The manual says not to remove the front cover unless the power is turned off or disconnected (navien-ncb-h-um-2501, p. 5), and not to operate the boiler with the front cover open (navien-ncb-h-um-2501, p. 4).
- Reset the boiler once: press Back on the front panel (navien-ncb-h-um-2501, p. 13).
- If E110 comes back, the manual’s next step is an authorized technician, a licensed professional or Navien Technical Support at 1-800-519-8794 (navien-ncb-h-um-2501, p. 24).
The NCB-H manual asks for the air intake filter to be cleaned every 3–4 months (navien-ncb-h-um-2501, p. 16).
On the NFC-H, NFB-H and NHB-H, the E110 row says only “Check exhaust venting.” and does not say who checks (navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24). Their user’s manuals do give the owner the filter procedure above, with the same power-off steps at the start, and link a clogged filter to “Error Code 110”. They ask for the filter to be cleaned “as needed or as part of the annual maintenance” (navien-nfc-h-um-c, pp. 15–16; navien-nfb-h-um, pp. 15–16; navien-nhb-h-um, pp. 16–17). The reset on all three is the Back button (navien-nfc-h-um-c, p. 13; navien-nfb-h-um, p. 13; navien-nhb-h-um, p. 14).
When to call a licensed technician
- E110 returns after the exhaust check, a clean filter and one reset (navien-ncb-h-um-2501, p. 24).
- A vent or intake pipe is damaged, loose or separated (navien-ncb-h-um-2501, p. 4). The manual’s cover says installation and service must be performed by a qualified installer, service agency or the gas supplier (navien-ncb-h-um-2501, p. 1).
- Anything inside the boiler beyond the air filter. Navien tells owners not to repair or replace any part unless the user’s manual specifically recommends it (navien-ncb-h-um-2501, p. 5).
- The seasonal inspection. A qualified technician should inspect the boiler at the beginning of every heating season and when there is a problem (navien-ncb-h-um-2501, p. 18).
Notes for different models
| Series and document | Wording | Action in the table | Source |
|---|---|---|---|
| NCB-H user’s manual | “Exhaust Blockage” | “Ensure that the exhaust pipe is free of obstructions.” and “Clean the intake air filter.” | navien-ncb-h-um-2501, p. 25 |
| NCB700 installation manual | “Exhaust Blockage” | The two NCB-H actions, with “Check that the condensate drain outlet is not blocked and is draining properly.” between them | navien-ncb700-io, p. 136 |
| NFC-H, NFB-H, NHB-H user’s manuals | “Exhaust Blockage” | “Check exhaust venting.” | navien-nfc-h-um-c, p. 24; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24 |
| NFC-H installation manual (March 2021) | “Abnormal air pressure” | “Manual RESET” | navien-nfc-h-io, p. 127 |
| NCB-E user’s manual | “Abnormal air pressure” | The same two actions as the NCB-H | navien-ncb-e-um, p. 22 |
| NFC installation manual | “Abnormal air pressure” | The same two actions as the NCB-H | navien-nfc-io, p. 101 |
| NFB, NHB, NFB-C user’s manuals | “Exhaust vent closed” | “Manual reset/Power On reset” | navien-nfb-um, p. 20; navien-nhb-um, p. 22; navien-nfb-c-um, p. 19 |
| NFB700-C installation manual | “Exhaust vent blocked” | “Manual reset/Power On reset” | navien-nfb700-c-io, p. 119 |
The manuals do not explain the labels “Manual reset” and “Power On reset”.
The filter procedure differs by series. On the NCB-E you unclasp three buckles to lift off the cover and clean the filter with a toothbrush and clean running water, every 3–4 months, after turning the boiler off and disconnecting its power (navien-ncb-e-um, pp. 14–15); the NCB-E reset is the Reset button (navien-ncb-e-um, p. 11). The NFB and NHB user’s manuals also give 3–4 months (navien-nfb-um, p. 12; navien-nhb-um, p. 13). The NFB-C has an internal air filter that is inspected and replaced, not cleaned, as needed or at least every two years; when it is fully blocked, “an error code may occur due to intake blockage being detected in the boiler”, with no code number given (navien-nfb-c-um, p. 12). The NFC-H service technician’s list also includes removing and cleaning the air intake filter “If combustion or performance indicate need” (navien-nfc-h-um-c, p. 18).
Navien’s NCB700 downloads page had no user’s manual on October 21, 2026, so these pages have no owner procedure for the NCB700.
Navien’s tankless water heaters have an E110 of their own, with their own table and remedies: see Navien tankless E110.
Related codes: E109, E012, E762. All Navien boilers codes
Navien boiler error code E302: low water pressure
Checked
Boiler front panel display
E302
“Low Water Pressure”
Printed on 6 model series · 6 documents
Short answer On Navien NFB-H, NHB-H, NCB700, NFB-C, NFB and NHB boilers, E302 means low water pressure; the NCB-H and NCB-E tables have E351 instead. The manuals give no refill step for owners: reset once, and if E302 stays, call a technician or Navien Technical Support. See what to check
What it means
E302 is “Low Water Pressure” in the NFB-H, NHB-H and NCB700 tables and “Low water pressure” in the NFB-C, NFB and NHB tables (navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24; navien-ncb700-io, p. 136; navien-nfb-c-um, p. 19; navien-nfb-um, p. 20; navien-nhb-um, p. 22).
The installation manuals say where it comes from. These boilers have a factory-installed, pressure-sensing low water cutoff (LWCO) with a minimum operation pressure of 6 psi by default. When the built-in water pressure sensor detects insufficient water level in the boiler, E302 appears on the front panel and the boiler needs a manual reset (navien-nfb-h-io, p. 19; navien-nhb-h-io, p. 17; navien-nfb-c-io, p. 22). The NCB700 manual says insufficient water pressure rather than level (navien-ncb700-io, p. 21).
Whether your boiler shows E302 depends on the series. The NCB-H, NCB-E, NFC-H and NFC tables have no E302. They have E351, the auto feeder (make-up water) valve code. The NFC-H and NFC installation manuals do mention E302 in their low water cutoff note, but E302 is not in their code tables or in the NFC-H user’s manual (navien-nfc-h-io, pp. 23, 127–128; navien-nfc-io, pp. 21, 101–102; navien-nfc-h-um-c, pp. 24–25).
Check these first
Navien’s user’s manuals give the owner no procedure for adding water or releasing pressure, and no normal pressure range. The NCB-H and NCB-E tables list “Add make-up water to the system if necessary.” for a different code, E777, without a procedure, and this page does not present it as an owner step (navien-ncb-h-um-2501, p. 26; navien-ncb-e-um, p. 22). What they do give for any error message is a reset, then a call:
- Reset the boiler once. Press Back on the NFB-H, NHB-H and NFB (navien-nfb-h-um, p. 13; navien-nhb-h-um, p. 14; navien-nfb-um, p. 10), Reset on the NHB (navien-nhb-um, p. 11), or press and hold Reset on the NFB-C (navien-nfb-c-um, p. 10). The installation manuals say E302 needs a manual reset (navien-nfb-h-io, p. 19).
- If E302 stays or comes back, the user’s manuals send you to an authorized technician, a licensed professional or Navien Technical Support at 1-800-519-8794 (navien-nfb-h-um, p. 22). Have the model number, serial number, date purchased, installation location and type, and the error code ready (navien-nfb-h-um, p. 27).
- On the NHB-H, all repairs require pre-authorization by Technical Support: your installer or a licensed professional calls 1-800-519-8794, Option 2, from the installation site (navien-nhb-h-um, p. 29).
The panel shows the pressure. On the NFB-H and NHB-H a system pressure icon displays the internal water pressure of the boiler system, and Status Information lists “Water Press” in psi (navien-nfb-h-um, pp. 7, 13; navien-nhb-h-um, pp. 7, 13). The user’s manuals give no normal range for the owner. The owner’s daily task in the maintenance schedule is to check the pressure/temperature gauge for signs of higher than normal pressure, not low pressure (navien-nfb-h-um, p. 17).
When to call a licensed technician
- Any E302 that does not clear with one reset or comes back.
- The check in the table. The NFB-H, NHB-H and NCB700 tables say “Check water pressure.” without saying who checks or what reading is correct (navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24; navien-ncb700-io, p. 136).
- Checking the system’s water pressure. The figures in Navien’s manuals are for the installer and the service technician. The technician’s annual start-up list asks for a cold fill pressure of at least 6 psi on the NFB-H and NHB-H and at least 12 psi on the NFB-C, NFB and NHB (navien-nfb-h-um, p. 19; navien-nhb-h-um, p. 20; navien-nfb-c-um, p. 15; navien-nfb-um, p. 16; navien-nhb-um, p. 18). The NFB-H installation manual describes heating systems “operating with 12-80 psi water pressure at the boiler outlet” (navien-nfb-h-io, p. 19).
- Anything inside the boiler. Navien tells owners not to repair or replace any part unless the user’s manual specifically recommends it (navien-nfb-h-um, p. 5).
Notes for different models
| Series and document | Low water code | Wording | Action in the table | Source |
|---|---|---|---|---|
| NFB-H, NHB-H user’s manuals | E302 | “Low Water Pressure” | “Check water pressure.” | navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24 |
| NCB700 installation manual | E302 | “Low Water Pressure” | “Check water pressure.” | navien-ncb700-io, p. 136 |
| NFB-C, NFB, NHB user’s manuals | E302 | “Low water pressure” | “Manual reset” | navien-nfb-c-um, p. 19; navien-nfb-um, p. 20; navien-nhb-um, p. 22 |
| NCB-H user’s manual | E351 | “Abnormal Auto Feeder Valve” | “Contact technical support at 1-800-519-8794.” | navien-ncb-h-um-2501, p. 25 |
| NCB-E user’s manual | E351 | “Abnormal Auto feeder valve (make-up water)” | “Contact Technical Support at 1-800-519-8794.” | navien-ncb-e-um, p. 22 |
| NFC-H, NFC | E351 in the tables; E302 in the installation manual’s text | navien-nfc-h-um-c, p. 24; navien-nfc-h-io, p. 23; navien-nfc-io, p. 21 |
The NFB700-C table has no E302; its low water row is E777, “Low Water Cut Off” (navien-nfb700-c-io, p. 120).
The low water cutoff numbers differ by series: 6 psi by default on the E302 boilers above, 7.3 psig on the NCB-H (navien-ncb-h-io, p. 20). Do not carry a number from one series to another.
E302 does not appear in the Navien tankless water heater tables used on this site.
Related codes: E351, E352, E353, E777. All Navien boilers codes
Navien combi boiler error code E351: auto feeder (make-up water) valve
Checked
Boiler front panel display
E351
“Abnormal Auto Feeder Valve”
Short answer On Navien NCB-H, NCB-E, NFC-H and NFC combi-boilers, E351 means an abnormal auto feeder (make-up water) valve; on the NCB-H it appears when the automatic refill is not completed after 5 minutes. Reset once; if it stays, contact Navien Technical Support. See what to check
What it means
E351 is the auto feeder valve code of four Navien combi-boiler series: “Abnormal Auto Feeder Valve” in the NCB-H table and “Abnormal Auto feeder valve (make-up water)” in the NCB-E and NFC tables (navien-ncb-h-um-2501, p. 25; navien-ncb-e-um, p. 22; navien-nfc-io, p. 101). The NFC-H uses one wording in each of its manuals (navien-nfc-h-um-c, p. 24; navien-nfc-h-io, p. 127).
The NCB-H installation manual says what sets it off. The boiler has a factory-installed, pressure-sensing low water cutoff with a minimum operation pressure of 7.3 psig. When the built-in water pressure sensor detects insufficient water level in the boiler system, the boiler refills itself automatically. If the refill is not completed after 5 minutes, E351 appears on the front panel and the boiler needs a manual reset (navien-ncb-h-io, p. 20).
The NFC-H and NFC installation manuals describe their low water cutoff differently: 6 psi by default, and E302 with a manual reset when the sensor detects insufficient water level (navien-nfc-h-io, p. 23; navien-nfc-io, p. 21). Yet E302 is not in either manual’s code table or in the NFC-H user’s manual, which list E351 (navien-nfc-h-io, pp. 127–128; navien-nfc-io, pp. 101–102; navien-nfc-h-um-c, pp. 24–25). Navien’s documents do not resolve this.
The NCB700 combi and the heating-only NFB-H, NHB-H, NFB-C, NFB and NHB have no E351; their low water code is E302. The NFB700-C table has neither code (navien-nfb700-c-io, pp. 119–120).
Check these first
For E351 the NCB-H and NCB-E tables give one action: contact Navien Technical Support at 1-800-519-8794 (navien-ncb-h-um-2501, p. 25; navien-ncb-e-um, p. 22). The user’s manuals give the owner no procedure for refilling the system. What they give for any error message is a reset, then a call:
- Reset the boiler once. On the NCB-H press Back on the front panel (navien-ncb-h-um-2501, p. 13); on the NCB-E press Reset (navien-ncb-e-um, p. 11). The installation manual says E351 needs a manual reset (navien-ncb-h-io, p. 20).
- If E351 stays or comes back, contact Navien Technical Support, as the table says (navien-ncb-h-um-2501, p. 25).
- Have the model number, serial number, date purchased, installation location and type, and the error code ready (navien-ncb-h-um-2501, p. 64).
The NCB-H panel shows the system pressure, and Status Information has a “16. Water Pressure” item in psi (navien-ncb-h-um-2501, pp. 8, 12). The user’s manual gives no normal range for the owner. The owner’s daily task in its maintenance schedule is to check the pressure/temperature gauge for signs of higher than normal pressure (navien-ncb-h-um-2501, p. 18).
On the NFC-H, the user’s manual row reads “Check valve and supply water.” and does not say who checks (navien-nfc-h-um-c, p. 24). Its reset is the Back button (navien-nfc-h-um-c, p. 13).
When to call a licensed technician
- Any E351 that does not clear with one reset or comes back (navien-ncb-h-um-2501, p. 25).
- The valve and water supply check from the NFC-H table (navien-nfc-h-um-c, p. 24).
- Checking the system’s water pressure. The figures in Navien’s manuals are for the technician: the annual start-up list asks for a cold fill pressure of at least 12 psi on the NCB-H and NCB-E and at least 6 psi on the NFC-H (navien-ncb-h-um-2501, p. 20; navien-ncb-e-um, p. 18; navien-nfc-h-um-c, p. 19).
- Anything inside the boiler. Navien tells owners not to repair or replace any part unless the user’s manual specifically recommends it (navien-ncb-h-um-2501, p. 5).
Notes for different models
| Series and document | Wording | Action in the table | Source |
|---|---|---|---|
| NCB-H user’s manual | “Abnormal Auto Feeder Valve” | “Contact technical support at 1-800-519-8794.” | navien-ncb-h-um-2501, p. 25 |
| NCB-E user’s manual | “Abnormal Auto feeder valve (make-up water)” | “Contact Technical Support at 1-800-519-8794.” | navien-ncb-e-um, p. 22 |
| NFC installation manual | “Abnormal Auto feeder valve (make-up water)” | “Contact technical support at 1-800-519-8794.” | navien-nfc-io, p. 101 |
| NFC-H user’s manual (April 2024) | “Abnormal Auto Feeder Valve” | “Check valve and supply water.” | navien-nfc-h-um-c, p. 24 |
| NFC-H installation manual (March 2021) | “Abnormal Auto feeder valve (make-up water)” | “Manual RESET” | navien-nfc-h-io, p. 127 |
The low water cutoff numbers differ: 7.3 psig on the NCB-H (navien-ncb-h-io, p. 20) and 6 psi by default on the NFC-H and NFC (navien-nfc-h-io, p. 23; navien-nfc-io, p. 21). Do not carry a number from one series to another.
E351 does not appear in the Navien tankless water heater tables used on this site.
Related codes: E302, E352, E353, E777. All Navien boilers codes
Navien combi boiler error code E407: hot water outlet sensor
Checked
Boiler front panel display
E407
“Dom.Hot Water Outlet Sensor”
Short answer On Navien combi-boilers, E407 flags the domestic hot water outlet sensor (NCB-E and NFC: thermistor open or short circuit). Reset once; if E407 stays, contact Navien Technical Support, since the manuals give no owner step for the sensor. See what to check
What it means
E407 is a domestic hot water code, and only the combi-boiler tables have it. The NCB-H, NCB700 and NFC-H tables call it “Dom.Hot Water Outlet Sensor” (navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136; navien-nfc-h-um-c, p. 24). The older wording names the part and the fault: “Hot water outlet: thermistor open or short circuit” on the NFC and in the 2021 NFC-H installation manual, and “Hot water outlet thermistor open or short circuit” on the NCB-E (navien-nfc-io, p. 101; navien-nfc-h-io, p. 127; navien-ncb-e-um, p. 22). The heating-only tables (NFB-H, NHB-H, NFB, NHB, NFB-C, NFB700-C) have no E407.
Check these first
The NCB-H, NCB700, NCB-E and NFC tables give one action for E407: contact Navien Technical Support at 1-800-519-8794 (navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136; navien-ncb-e-um, p. 22; navien-nfc-io, p. 101). The user’s manuals give the owner no step for the sensor. What they give for any error message is a reset, then a call:
- Reset the boiler once. On the NCB-H press Back on the front panel (navien-ncb-h-um-2501, p. 13); on the NCB-E press Reset (navien-ncb-e-um, p. 11).
- If E407 stays or comes back, contact Navien Technical Support, as the table says (navien-ncb-h-um-2501, p. 25).
- Have the model number, serial number, date purchased, installation location and type, and the error code ready (navien-ncb-h-um-2501, p. 64).
On the NFC-H, the user’s manual row reads “Check thermistor connector.” and does not say who checks (navien-nfc-h-um-c, p. 24). The manual gives the owner no procedure for it. It says not to remove the front cover unless the power to the boiler is turned off or disconnected, and not to repair or replace any part unless the manual specifically recommends it (navien-nfc-h-um-c, p. 5). The NFC-H reset is the Back button (navien-nfc-h-um-c, p. 13).
When to call a licensed technician
- Any E407 that does not clear with one reset or comes back (navien-ncb-h-um-2501, p. 25).
- The thermistor connector check from the NFC-H table (navien-nfc-h-um-c, p. 24).
- Anything inside the boiler. Navien tells owners not to repair or replace any part unless the user’s manual specifically recommends it (navien-ncb-h-um-2501, p. 5).
Notes for different models
| Series and document | Wording | Action in the table | Source |
|---|---|---|---|
| NCB-H user’s manual, NCB700 installation manual | “Dom.Hot Water Outlet Sensor” | “Contact technical support at 1-800-519-8794.” | navien-ncb-h-um-2501, p. 25; navien-ncb700-io, p. 136 |
| NFC-H user’s manual (April 2024) | “Dom.Hot Water Outlet Sensor” | “Check thermistor connector.” | navien-nfc-h-um-c, p. 24 |
| NFC-H installation manual (March 2021) | “Hot water outlet: thermistor open or short circuit” | “Auto RESET” | navien-nfc-h-io, p. 127 |
| NFC installation manual | “Hot water outlet: thermistor open or short circuit” | “Contact technical support at 1-800-519-8794.” | navien-nfc-io, p. 101 |
| NCB-E user’s manual | “Hot water outlet thermistor open or short circuit” | “Contact Technical Support at 1-800-519-8794.” | navien-ncb-e-um, p. 22 |
The manuals do not explain the “Auto RESET” label. The same tables have codes for other domestic water sensors, such as E421 “Dom.Cold Water Inlet Sensor” and E441 “Dom.Hot Water Outlet2 Sensor” on the NCB-H (navien-ncb-h-um-2501, p. 25).
Navien’s tankless water heaters also have an E407 in their table, with a table of their own; see the Navien tankless table. Read a combi-boiler’s E407 in the boiler table.
Related codes: E421, E441, E439. All Navien boilers codes
Navien boiler error code E762: vent pipe not fully inserted
Checked
Boiler front panel display
E762
“Vent Pipe Not Fully Inserted”
Printed on 5 model series · 5 documents
Short answer On Navien NCB-H, NCB700, NFC-H, NFB-H and NHB-H boilers, E762 means the vent pipe is not fully inserted in the exhaust collar, and the boiler does not run. Reseating the pipe is installer work; call your installer or Navien Technical Support. See what to check
What it means
E762 is “Vent Pipe Not Fully Inserted” in the NCB-H, NCB700, NFC-H, NFB-H and NHB-H tables (navien-ncb-h-um-2501, p. 26; navien-ncb700-io, p. 137; navien-nfc-h-um-c, p. 25; navien-nfb-h-um, p. 23; navien-nhb-h-um, p. 24). The installation manuals tie it to the vent installation detector (VID). During installation, the VID detects whether the vent pipe is fully inserted into the collar, at least 2-3/4” (70 mm). A correctly sized vent pipe (2.0 inches) pushed fully in presses against a switch; if the pipe is not fully inserted, the unit displays an error message and does not operate (navien-ncb-h-io, p. 62; navien-ncb700-io, p. 62; navien-nhb-h-io, p. 55).
The VID text in these manuals is about installation. The user’s manuals separately ask for the vent termination and air intake supply to be inspected every year (navien-ncb-h-um-2501, p. 4).
The NCB-E, NFC, NFB, NHB, NFB-C and NFB700-C tables have no E762 (navien-ncb-e-um, p. 22; navien-nfc-io, pp. 101–102; navien-nfb-um, p. 20; navien-nhb-um, p. 22; navien-nfb-c-um, p. 19; navien-nfb700-c-io, pp. 119–120).
Check these first
The tables split here. On the NCB-H and NCB700 the action is “Contact technical support at 1-800-519-8794.” (navien-ncb-h-um-2501, p. 26; navien-ncb700-io, p. 137). On the NFC-H, NFB-H and NHB-H the user’s manual row says to insert the pipe into the exhaust collar to a stated depth (see the notes below). Inserting the vent pipe is venting work: the user’s manual cover says installation and service must be performed by a qualified installer, service agency or the gas supplier (navien-ncb-h-um-2501, p. 1). What an owner can do:
- The owner maintenance schedule includes a monthly visual inspection of “the vent piping for signs of leakage and blockage” (navien-ncb-h-um-2501, p. 18). If any vent pipe, vent elbow or intake pipe is damaged, separated at a joint, or shows corrosion, rusting or melting, the manual says to turn the boiler off and discontinue use (navien-ncb-h-um-2501, p. 4).
- Keep in mind Navien’s warning: do not operate the boiler without proper venting, because doing so may result in fire or carbon monoxide poisoning (navien-ncb-h-um-2501, p. 4).
- Call the professional who installed the boiler or Navien Technical Support at 1-800-519-8794 (navien-ncb-h-um-2501, p. 64). On the NHB-H, all repairs require pre-authorization by Technical Support, and your installer or a licensed professional calls 1-800-519-8794, Option 2, from the installation site (navien-nhb-h-um, p. 29).
When to call a licensed technician
- Any E762. Seating the vent pipe at the right depth is part of the installation that the VID checks (navien-ncb-h-io, p. 62).
- Checking the pipe size. The VID text names a correctly sized vent pipe of 2.0 inches (navien-ncb-h-io, p. 62; navien-nfb-h-io, p. 57; navien-nfc-h-io, p. 65).
- Any damaged, loose or separated vent or intake pipe (navien-ncb-h-um-2501, p. 4).
- The seasonal inspection. A qualified technician should inspect the boiler at the beginning of every heating season and when there is a problem (navien-ncb-h-um-2501, p. 18).
Notes for different models
The depth differs between series and even between documents for the same series. These figures are for the installer.
| Series and document | Action in the code table | VID text in the installation manual |
|---|---|---|
| NCB-H | “Contact technical support at 1-800-519-8794.” (navien-ncb-h-um-2501, p. 26) | at least 2-3/4” (70 mm) (navien-ncb-h-io, p. 62) |
| NCB700 | “Contact technical support at 1-800-519-8794.” (navien-ncb700-io, p. 137) | at least 2-3/4” (70 mm) (navien-ncb700-io, p. 62) |
| NHB-H | “Insert pipe 2-¾” (70 mm) into exhaust collar.” (navien-nhb-h-um, p. 24; navien-nhb-h-io, p. 119) | at least 2-3/4” (70 mm) (navien-nhb-h-io, p. 55) |
| NFB-H user’s manual | “Insert pipe 2-¾ inches into exhaust collar.” (navien-nfb-h-um, p. 23) | at least 2-3/4” (70 mm) (navien-nfb-h-io, p. 57) |
| NFB-H installation manual | “Insert pipe 3 inches into exhaust collar.” (navien-nfb-h-io, p. 116) | at least 2-3/4” (70 mm) in the same manual (navien-nfb-h-io, p. 57) |
| NFC-H user’s manual (April 2024) | “Insert pipe 2-¾ inches into exhaust collar.” (navien-nfc-h-um-c, p. 25) | not in the user’s manual |
| NFC-H installation manual (March 2021) | “Abnormal flue gas duct: Vent pipe not properly inserted”, “Auto RESET” (navien-nfc-h-io, p. 128) | at least 3.0 inches or 76 mm (navien-nfc-h-io, p. 65) |
The NFC-H manuals disagree with each other: 2-¾ inches in the 2024 user’s manual and at least 3.0 inches in the 2021 installation manual. The NFB-H installation manual gives 3 inches in its code table and at least 2-3/4” in its VID text. Navien’s documents do not say which figure applies.
Navien’s tankless water heaters also have an E762, with their own table and remedies: see Navien tankless E762.
Related codes: E110, E030. All Navien boilers codes
How to read a Navien boiler code
The code appears on the boiler’s front panel. Navien’s code tables write it as E plus three digits, such as E003 or E110, and the user’s manuals also refer to it in text as, for example, “Error Code 110” (navien-ncb-h-um-2501, pp. 16, 25). On the NCB-H, the “System check or error” icon is displayed “when an error is detected or a system check is needed due to service alarm overtime” (navien-ncb-h-um-2501, p. 8). The NCB-E manual says of its Error icon: “A code will appear on the display.” (navien-ncb-e-um, p. 7). The NFB-C has a touch screen; its ERROR status means combustion has stopped because of an error, and tapping the operating status display shows the details (navien-nfb-c-um, p. 9).
The installation manuals describe an error history: press Menu and select “4. Error History” to see the 10 most recent errors, newest at the top (navien-ncb-h-io, p. 118; navien-ncb700-io, p. 123; navien-nfc-h-io, p. 116; navien-nfb-h-io, p. 104; navien-nhb-h-io, p. 108). On the NFC the menu item is “5. Error History” (navien-nfc-io, p. 93).
When you call Navien, the user’s manuals ask you to have the model number, serial number, date purchased, installation location and type, and the error code shown on the display (navien-ncb-h-um-2501, p. 64).
Combi or heating-only: find your series
The manual covers name the type: “Condensing Combi-Boilers” for the combis and “Condensing Boilers” for the heating-only models. Match the model number on your boiler to the models below, then read the code in that series’ table. The status column is from navieninc.com, checked October 21, 2026: the older series are on Navien’s Discontinued Products page, and the NFB-C and NFB700-C are listed under Commercial only.
| Series | Type on the cover | Models on the cover | Code table | Status |
|---|---|---|---|---|
| NCB-H | Combi-Boilers | NCB-190/060H, NCB-190/080H, NCB-240/110H, NCB-240/130H, NCB-250/150H | navien-ncb-h-um-2501, pp. 25–26 | current |
| NCB700 | Combi-Boilers | NCB700-190/060, NCB700-190/080, NCB700-240/110, NCB700-240/130, NCB700-250/150 | navien-ncb700-io, pp. 136–137 | current |
| NFC-H | Combi-Boilers | NFC-250/175H, NFC-250/200H | navien-nfc-h-um-c, pp. 24–25 | current |
| NFB-H | Boilers | NFB-175H, NFB-200H | navien-nfb-h-um, p. 23 | current |
| NHB-H | Boilers | NHB-055H, NHB-080H, NHB-110H, NHB-150H | navien-nhb-h-um, p. 24 | current |
| NFB-C | Boilers (cover: “NFB Condensing Boilers”) | NFB-301C, NFB-399C | navien-nfb-c-um, p. 19 | commercial |
| NFB700-C | Commercial Condensing Boilers | NFB700-500C, NFB700-600C, NFB700-800C, NFB700-1000C | navien-nfb700-c-io, pp. 119–120 | commercial |
| NCB-E | Combi-Boilers | NCB-150E, NCB-180E, NCB-210E, NCB-240E | navien-ncb-e-um, p. 22 | discontinued |
| NFC | Combi-Boilers | NFC-175, NFC-200 | navien-nfc-io, pp. 101–102 | discontinued |
| NFB | Boilers | NFB-175, NFB-200 | navien-nfb-um, p. 20 | discontinued |
| NHB | Boilers | NHB-055, NHB-080, NHB-110, NHB-150 | navien-nhb-um, p. 22 | discontinued |
The user’s manuals do not say where the model number is printed. The NCB-H installation manual has a section on the rating plate (navien-ncb-h-io, p. 13), and the NHB-H user’s manual has a box for the model, date purchased, gas type and serial number (navien-nhb-h-um, p. 2).
Some series have no user’s manual of their own on Navien’s site. The NCB700 and the NFC have only an installation manual (the user’s manual posted on the NFC page is the NFC-H one), so these pages quote their tables from the installation manual. These pages have no code table for the older NCB-180, NCB-210 and NCB-240: the “NCB User’s Information Manual” on Navien’s NCB downloads page is the NCB-H edition of January 2025, and the 2013 NCB installation manual has no code table (navieninc.com, checked October 21, 2026).
The NCB-H user’s manual exists in two editions, April 2024 and January 2025, and the documents do not say which one goes with which boiler. The tables match, except that the January 2025 edition adds E020 and E123 and changes the E060 action to “Check dual venturi.” (navien-ncb-h-um-2404, pp. 25–26; navien-ncb-h-um-2501, p. 25). These pages quote the January 2025 edition.
Why one code number reads by series
The same number can carry different words and a different kind of action, so take both from the row for your series.
- E110 is “Exhaust Blockage” on the NCB-H, NCB700, NFC-H, NFB-H and NHB-H, “Abnormal air pressure” on the NCB-E and NFC, “Exhaust vent closed” on the NFB, NHB and NFB-C, and “Exhaust vent blocked” on the NFB700-C (navien-ncb-h-um-2501, p. 25; navien-ncb-e-um, p. 22; navien-nfb-um, p. 20; navien-nfb700-c-io, p. 119).
- The low water code depends on the series. The NFB-H, NHB-H, NCB700, NFB-C, NFB and NHB tables have E302, “Low Water Pressure”. The NCB-H, NCB-E, NFC-H and NFC tables have no E302; they have E351, the auto feeder (make-up water) valve. The NFC-H and NFC installation manuals mention E302 in their text, but not in their code tables (navien-nfc-h-io, p. 23; navien-nfc-io, p. 21).
- The action column means different things. In the NCB-H, NCB-E, NCB700 and NFC tables it is an action, such as “Ensure that the main gas supply valve is open.” for E003, or “Contact technical support at 1-800-519-8794.” The NFC-H, NFB-H and NHB-H user’s manuals give short checks, such as “Check gas supply valve and igniter.”, without saying who does them. The NFB, NHB, NFB-C and NFB700-C tables list labels such as “Manual reset/Power On reset” or “Alarm”, which none of the manuals explains (navien-ncb-h-um-2501, p. 25; navien-nfb-h-um, p. 23; navien-nfb-um, p. 20).
- Numbers inside a row differ too. For E762 the user’s manuals of the NFB-H and NFC-H say to insert the vent pipe 2-¾ inches into the exhaust collar, while the NFB-H installation manual’s table says 3 inches (navien-nfb-h-um, p. 23; navien-nfc-h-um-c, p. 25; navien-nfb-h-io, p. 116).
- One boiler can have two different tables. The NFC-H installation manual (March 2021) and user’s manual (April 2024) list the same 39 codes, but the wording or the action differs on every row. E001, for example, is “Heatexchanger over temperature” with “Manual RESET Auto RESET” in the first and “Heat Exchanger Overheat” with “Check for proper system flow.” in the second (navien-nfc-h-io, p. 127; navien-nfc-h-um-c, p. 24).
Navien boiler codes and Navien tankless codes
Navien’s tankless water heaters use E-codes as well, and many numbers appear in both, among them E003, E012, E110 and E515. On some series the words and the remedy match a boiler’s, on others they do not: E110 is “Abnormal air pressure” in the tankless tables and “Exhaust Blockage” in the NCB-H table, and E762 is “Vent pipe not properly inserted” there and “Vent Pipe Not Fully Inserted” here. So read a boiler code in the boiler table and a water heater code in the Navien tankless table. Some boiler codes, such as E001, E302 and E351, are not in the tankless tables at all. E438 works the other way: it is in Navien’s tankless tables and in none of the boiler documents used for these pages.
What the user’s manuals ask of the owner
Navien’s user’s manuals tell the owner not to repair or replace any part of the boiler unless the manual specifically recommends it, and to contact an authorized technician or licensed professional for all other service (navien-ncb-h-um-2501, p. 5). The owner maintenance schedule in the NCB-H manual includes these items (navien-ncb-h-um-2501, p. 18):
- Daily, check the pressure/temperature gauge “for signs of higher than normal pressure”. The front panel also shows the system pressure, and Status Information has a Water Pressure item in psi (navien-ncb-h-um-2501, pp. 8, 12). The user’s manuals give the owner no normal range and no procedure for adding water or releasing pressure. The pressure figures they do print, such as a minimum cold fill pressure of 12 psi for the NCB-H or 6 psi for the NFB-H, are in the service technician’s section (navien-ncb-h-um-2501, p. 20; navien-nfb-h-um, p. 19).
- Monthly, inspect the condensate trap and the PVC fittings. Cleaning the trap is in the service technician’s section (navien-ncb-h-um-2501, p. 20). The NCB-E schedule words the monthly item “Check condensate drain” (navien-ncb-e-um, p. 17).
- Monthly, visually inspect the vent piping for signs of leakage and blockage.
The same manuals give the owner a procedure for cleaning the air intake filter, which starts by turning the boiler off and disconnecting its power before the front cover comes off (navien-ncb-h-um-2501, pp. 16–17). The interval is every 3–4 months on the NCB-H, NCB-E, NFB and NHB, and “as needed or as part of the annual maintenance” on the NFC-H, NFB-H and NHB-H. The NFB-C has an internal air filter that is inspected and replaced as needed or at least every two years (navien-ncb-h-um-2501, p. 16; navien-ncb-e-um, p. 14; navien-nfb-um, p. 12; navien-nhb-um, p. 13; navien-nfc-h-um-c, p. 15; navien-nfb-c-um, p. 12). Removing and cleaning the filter also appears in the service technician’s list, “If combustion or performance indicate need” (navien-ncb-h-um-2501, p. 19).
When there is no code, the NCB-H troubleshooting chart covers a few symptoms. When the water from the hot water faucet is cold, it asks whether the faucet is open wide enough to draw at least 0.5 gallons per minute (GPM) through the boiler, and for space heating it notes that the heating side does not work while the unit is heating domestic hot water (navien-ncb-h-um-2501, p. 24).
Clearing a code
The reset button depends on the series:
- NCB-H, NFC-H, NFB-H, NHB-H and NFB: press Back on the front panel (navien-ncb-h-um-2501, p. 13; navien-nfc-h-um-c, p. 13; navien-nfb-h-um, p. 13; navien-nhb-h-um, p. 14; navien-nfb-um, p. 10).
- NCB-E and NHB: press Reset (navien-ncb-e-um, p. 11; navien-nhb-um, p. 11).
- NFB-C: press and hold Reset (navien-nfb-c-um, p. 10).
- NCB700 and NFC, from their installation manuals: press Back (navien-ncb700-io, p. 116; navien-nfc-io, p. 87). NFB700-C: tap Reset (navien-nfb700-c-io, p. 95).
If resetting does not solve the problem, the manuals point to their troubleshooting section or Navien Technical Support at 1-800-519-8794 (navien-ncb-h-um-2501, p. 13). After a power failure the boiler starts again by itself, and a manual reset is not required (navien-ncb-h-um-2501, p. 7).
The installation manuals describe “level 1” errors. The display flashes red, the boiler keeps operating, and the error clears automatically when the problem is resolved; pressing the Power button also clears it if the problem has been resolved (navien-ncb-h-io, p. 119). They do not say which codes are level 1.
If a code returns after the reset and the remedies for your series, the manual’s next step is an authorized technician, a licensed professional or Technical Support (navien-ncb-h-um-2501, p. 24).
When to stop and call a professional
- You smell gas. The steps from the NCB-H user’s manual are at the top of every code page (navien-ncb-h-um-2501, p. 1). The manual adds that the boiler has no pilot and must not be lit by hand, and that before operating it you should smell all around the appliance area, next to the floor as well, because some gas is heavier than air (navien-ncb-h-um-2501, p. 3).
- Any part of the boiler has been under water. Do not use it; the manual says to call a qualified service technician at once to inspect it and replace any part of the control system and any gas control that was under water (navien-ncb-h-um-2501, p. 3).
- A vent pipe, vent elbow or intake pipe is damaged, separated at a joint, or shows corrosion, rusting or melting. Turn the boiler off and stop using it. The same page warns against operating the boiler with the front cover open or without proper venting, because of the risk of fire or carbon monoxide poisoning (navien-ncb-h-um-2501, p. 4).
- The fix is inside the boiler, other than the owner procedures the manual gives (navien-ncb-h-um-2501, p. 5).
- The relief valve needs an inspection. The manual says this inspection must only be conducted by a plumbing contractor or authorized inspection agency, not by the owner (navien-ncb-h-um-2501, p. 21).
- A code keeps coming back. The manual says a qualified technician should inspect the boiler at the beginning of every heating season and when there is a problem (navien-ncb-h-um-2501, p. 18).
The 2024 and 2025 user’s manuals say the installer is required to confirm that at least one carbon monoxide alarm is installed in the living space before the boiler is put into operation (navien-ncb-h-um-2501, p. 10; navien-nfb-h-um, p. 9). The NFB, NHB and NCB-E user’s manuals of 2018 and 2019 do not have this note.
For service, the user’s manuals list Navien Technical Support at 1-800-519-8794 (for warranty service, contact Technical Support first), the technician or professional who installed the boiler, or a licensed professional for the affected system (navien-ncb-h-um-2501, p. 64). The NHB-H manual differs: all repairs require pre-authorization by Technical Support, and your installer or a licensed professional calls 1-800-519-8794, Option 2, from the installation site (navien-nhb-h-um, p. 29). The other user’s manuals do not include that requirement.
Navien’s service manuals for these boilers open only after accepting a notice that they are meant for qualified, licensed professionals. These pages do not use them, so they give no causes or checks per code beyond what the tables and the user’s and installation manuals print (navieninc.com, checked October 21, 2026).
See also
- Heat pump vs gas calculator
- Furnace and HVAC tax credits for 2025 and 2026: 25C ended after 2025
- Form 5695 for 2025 and 2026: QMID, lines, carryforward
- Home maintenance schedule from the manuals: monthly to yearly
- Winter home maintenance checklist: furnace, boiler, water heater
Other gas boilers: Weil-McLain
Navien is a trademark of its owner. How House Works is not affiliated with or endorsed by Navien.
Sources
19 documents
- Navien, Inc.. User's Information Manual NCB-H Condensing Combi-Boilers. Version: 1.0 (January, 2025), part no. 20050970B. Accessed Oct 21, 2026.
- Navien, Inc.. Installation & Operation Manual NCB700 Condensing Combi-Boilers. Version: 1.0 (July, 2026). Accessed Oct 21, 2026.
- Navien, Inc.. User's Information Manual NFC-H Condensing Combi-Boilers. Version: 1.0 (April, 2024), part no. 20052125C. Accessed Oct 21, 2026.
- Navien, Inc.. User's Information Manual NFB-H Condensing Boilers. Version: 1.0 (April, 2024). Accessed Oct 21, 2026.
- Navien, Inc.. Installation and Operation Manual NHB-H Condensing Boilers. Version: 1.0 (April, 2026). Accessed Oct 21, 2026.
- Navien, Inc.. Installation Manual NFC-H Condensing Combi-Boilers. Version: 1.0 (March, 2021). Accessed Oct 21, 2026.
- Navien, Inc.. Installation & Operation Manual NFC Condensing Combi-Boilers. Version: 1.0 (Jan 25, 2019). Accessed Oct 21, 2026.
- Navien, Inc.. User's Information Manual NFB Condensing Boilers. Version: 1.0 (April, 2024). Accessed Oct 21, 2026.
- Navien, Inc.. Installation & Operation Manual NFB700 Commercial Condensing Boilers. Version: 1.0 (July, 2026). Accessed Oct 21, 2026.
- Navien, Inc.. User's Information Manual NFB Condensing Boilers. Version: 1.1 (July 4, 2018). Accessed Oct 21, 2026.
- Navien, Inc.. User's Information Manual NHB Condensing Boilers. Version: 2.0 (May 30, 2019), part no. 20032170C. Accessed Oct 21, 2026.
- Navien, Inc.. User's Information Manual NCB-E Condensing Combi-Boilers. Version : 6.0 (May 27, 2019), part no. 20035566B. Accessed Oct 21, 2026.
- Navien, Inc.. User's Information Manual NCB-H Condensing Combi-Boilers. Version: 1.0 (April, 2024). Accessed Oct 21, 2026.
- Navien, Inc.. Installation & Operation Manual NCB-H Condensing Combi-Boilers. Version: 1.0 (February, 2024). Accessed Oct 21, 2026.
- Navien, Inc.. User's Information Manual NFC-H Condensing Combi-Boilers. Version: 1.0 (April, 2024), part no. 20052125A. Accessed Oct 21, 2026.
- Navien, Inc.. Installation Manual NFB-H Condensing Boilers. Version: 1.0 (February, 2024). Accessed Oct 21, 2026.
- Navien, Inc.. User's Information Manual NHB-H Condensing Boilers. Version: 1.0 (April, 2024). Accessed Oct 21, 2026.
- Navien, Inc.. Installation & Operation Manual NFB Condensing Boilers. Version: 1.0 (February, 2024). Accessed Oct 21, 2026.
- Navien, Inc.. NCB-H Emergency Kit Quick Guide. no version printed (file name dated 200821). Printed title "Emergency Part Kit"; tied to the NCB-H by its download page and file name. Accessed Oct 21, 2026.