Noritz tankless water heater error codes, each with the manual page

65 codes for EZ, NRCR, EZTR40, NRC661A/NRC711, NRC661, NRC98/NRC111/NERC, NRC (2013), NRC111 (2009), NRCP, NR98/NR83/NR71DVC, NR501/NR662/NER66, NR (2009–2013), each with the wording and page from Noritz's manuals.

How House Works EditorialChecked against 40 sources,
How it is checked
Methodology
Page
HHW · ERROR-CODES · NORITZ
Based on
Noritz manuals

Meanings are quoted from Noritz's manuals. The "Who" column is our reading of the manual's remedy: whether an owner can do the first checks, or the fix belongs to a licensed technician.

Codes with step-by-step checks

  • 11Ignition failure
  • 29Condensate drain or air pressure switch
  • 63Recirculation abnormality
  • F76Multi-system communication error
  • 90Combustion abnormality
  • 903Abnormal combustion

How it works: How a tankless water heater lights: ignition codes by brand

All Noritz codes

CodeManual meaningWhoSeriesSource
05“Service warning”
The guide says the heater has an automatic service reminder, to contact the nearest Noritz agent, and to reset the display only after the heater is flushed and/or the water treatment device is serviced (NRC83/NRC98 Owner's Guide Rev. 03/13, p. 27). Field Manual KS-11-0004, a training document for service technicians that also covers NR981 models, calls it “Service Reminder” and says the reminder is optional and off by default (pp. 26, 32).
TechnicianNRC (2013)NRC83/NRC98 guide 03/13 p. 27; Field Manual KS-11-0004 p. 26
06“Recirculation abnormality”
NRCR models only. The 2025 guide lists it as 06, 061 and 062, with checks of the return line filter and the crossover valve's filter (EZ/NRCR Owner's Guide Rev. 10/25, p. 31). The 2021 guide uses 06 for “Low recirculation flow (Only warning indication. The water heater will continue to operate.)”, with only the return line filter check (NRCR Owner's Guide Rev. 04/21, p. 19); NRCR Technical Sheet FPHK081 also calls 06 “Low recirculation flow”, a warning only (p. 1).
Owner checks, then technicianNRCREZ/NRCR guide 10/25 p. 31; EZ/NRCR guide 01/24 p. 25
10“Combustion abnormality”
Listed only in Noritz technical documents for service technicians. The EZ sheets say 10 is kept only in the error code history; the 2025 sheet adds that it occurs only at high fan speed, when a blockage is detected and the fan speed is limited (EZ Technical Sheet FPFK081, p. 1). Field Manuals: “Combustion Abnormality”, in tables that do not say which models show it.
TechnicianEZ, Field Manual (models not listed)
6 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZ tech sheet FABK080 p. 1; EZ tech sheet FDAK080 p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
11“Ignition failure”
What to check
“Ignition error” in EZ Owner's Guide SBB80T9-2 (p. 28) and in the EZTR40, NRC, NERC, NR and NER66OD guides. NRCP heaters show Er:11, “Ignition has Failed 10 (Ten) Times” (NRCP1112/NRCP982 Owner's Guide Rev. 05/19, p. 39). Technical sheets: “Ignition failure (Initial flame fault detection)”.
Owner checks, then technician
12 seriesEZ, NRCR, EZTR40, NRC661A/NRC711, NRC661, NRC98/NRC111/NERC, NRC (2013), NRC111 (2009), NRCP, NR98/NR83/NR71DVC, NR501/NR662/NER66, NR (2009–2013)
11 documentsEZ/NRCR guide 10/25 p. 31; EZTR40 guide p. 24; NRC661A/NRC711 guide p. 25; NRC661 guide p. 25; NRC98 guide 01/17 p. 28; NRC83/NRC98 guide 03/13 p. 26; NRC111 guide 09/09 p. 27; NRCP1112/NRCP982 guide p. 39; NR98 guide 11/20 p. 26; NR501/NR662 guide p. 24; NR50/NR66/NR71 guide p. 26
12“Flame Rod does not detect flame (Flame fault detection)”
Listed only in Noritz technical documents for service technicians. Also shown as 12-1 or 12-2 (2025 EZ sheet) and as 121 or 122 (2024 EZ sheet; EZTR40, NRC661A/NRC711 and NRC661 sheets, where the remote shows 12). EZ Installation Manual Rev. 10/25 calls 121 and 122 “Flame loss” (p. 61). Field Manuals: “Flame Rod Does Not Detect Flame (Secondary Flame Fault Detection)”. NRCP data sheets list Er12 as “Flame Loss” (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2).
Technician
5 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, Field Manual (models not listed)
8 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34; EZ install manual 10/25 p. 61
13“External CO detector triggered”
Listed only in Noritz technical documents for service technicians. 2021 and 2024 EZ sheets: “External CO alarm triggered”. Also shown as 13-6 (2025 sheet) or 136 (2024 sheet). EZ Installation Manual Rev. 10/25 shows “External CO Alarm Triggered 13” in its test of a connected CO alarm (p. 50).
TechnicianEZEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZ tech sheet FABK080 p. 1; EZ install manual 10/25 p. 50
14“Thermal Fuse triggered”
Listed only in Noritz technical documents for service technicians. Not on the 2021 EZ sheets. EZTR40, NRC661A/NRC711 and NRC661 sheets: “Overheat Prevention Device (Thermal Fuse) triggered”, reset by disconnecting and reconnecting power (EZTR40 Technical Sheet EXSK072, p. 1). Field Manuals: “Overheat Cutoff Fuse”.
Technician
5 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, Field Manual (models not listed)
7 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
15“Abnormally high input temperature”
Listed only in Noritz technical documents for service technicians. Only on the 2021 EZ sheets.
TechnicianEZEZ tech sheet FABK080 p. 1; EZ tech sheet FDAK080 p. 1
16“Abnormally high output temperature”
Listed only in Noritz technical documents for service technicians. Also shown as 16-# (2025 EZ sheet), 16# (2024 EZ sheet) or 161, 162 and 163 (EZTR40, NRC661A/NRC711 and NRC661 sheets, where the remote shows 16). Field Manuals: “Abnormally High Output Temperature”. On NRCP heaters Er16 is a different entry, “Overheating HEX and DHW Temperature Sensor” (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2; NRCP111/NRCP98 Technical Data Sheet Rev. 07/19, p. 2).
Technician
5 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, Field Manual (models not listed)
7 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
20“High Limit Switch triggered”
Listed only in Noritz technical documents for service technicians. The EZ sheets say it may be caused by scale build-up in the heat exchanger and is reset by disconnecting and reconnecting power (EZ Technical Sheet FPFK081, p. 1). 2024 EZ sheet: “High Limit Switch -Heat Exchanger triggered”; 2021 EZ sheets: “High Limit Switch -Primary Heat Exchanger triggered”. Field Manuals: “High Limit Switch”. On NRCP heaters Er20 reads “Water High Limit Switch Abnormality” (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2; NRCP111/NRCP98 Technical Data Sheet Rev. 07/19, p. 2).
Technician
5 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, Field Manual (models not listed)
8 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZ tech sheet FABK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
21“High Limit Switch -Burner Chamber triggered”
Listed only in Noritz technical documents for service technicians. Only on the 2021 EZ sheet FABK080, which says to contact the nearest Noritz agent to reset it (EZ Technical Sheet FABK080, p. 1). The Field Manuals use 21 for a different entry, “Pressure Switch Abnormality”, with remedies that end “(For N-1321M-ASME)”, a model this table does not cover (Field Manual KS-11-0004, p. 26; Field Manual June 2011, p. 34).
TechnicianEZEZ tech sheet FABK080 p. 1
29“Clogging of condensate trap or drain pipe”
What to check
Other models use 29 for other faults. NRCP (Er:29): “Air Pressure Switch Abnormality” (NRCP1112/NRCP982 Owner's Guide Rev. 05/19, p. 39; NRCP111/NRCP98 Owner's Guide Rev. 05/19, p. 34). NRC111 Owner's Guide Rev. 09/09: “Clogging of neutralizer” (p. 27). EZ technical sheets: “External Condensate Pump abnormality”, shown only if an external condensate pump is interlocked with the heater (EZ Technical Sheet FPFK081, p. 1), and “Condensate pump abnormality (Only if connected to the water heater)” (EZ Technical Sheet FHCK080, p. 1). EZTR40, NRC661A/NRC711 and NRC661 sheets: “Condensate Container clogging” (EZTR40 Technical Sheet EXSK072, p. 1). Field Manual KS-11-0004: “Neutralizer Water Level Electrode Abnormality” (p. 26).
Owner checks, then technician
5 seriesEZTR40, NRC661A/NRC711, NRC661, NRC98/NRC111/NERC, NRC (2013)
9 documentsNRC98 guide 01/17 p. 28; NRC111 guide 01/17 p. 28; NERC98DV guide p. 28; NERC11DV guide p. 28; NRC83/NRC98 guide 03/13 p. 26; NRC1111 guide p. 27; EZTR40 guide p. 24; NRC661A/NRC711 guide p. 25; NRC661 guide p. 25
30“Thermistor-Air abnormality”
Listed only in Noritz technical documents for service technicians. Also shown as 30-1 or 30-2 (2025 EZ sheet) and 301 or 302 (2024 EZ sheet; EZTR40, NRC661A/NRC711 and NRC661 sheets, where 301 is an open circuit and 302 a short circuit). The Field Manuals use 30 for “Freeze Protection Thermostat” (Field Manual KS-11-0004, p. 26; Field Manual June 2011, p. 34).
TechnicianEZ, EZTR40, NRC661A/NRC711, NRC661
5 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1
31“Thermistor-Cold Water abnormality”
Listed only in Noritz technical documents for service technicians. Also shown as 31-1, 31-2, 311 or 312. NRCP: Er31 “Cold Water Inlet Thermistor Open or Short Circuit” (NRCP1112/NRCP982) or “Cold Water Thermistor Open or Short” (NRCP111/NRCP98). Field Manuals: “Inlet Thermistor Abnormality”.
Technician
6 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, NRCP, Field Manual (models not listed)
9 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; NRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
32“Thermistor-Hot Water abnormality”
Listed only in Noritz technical documents for service technicians. Also shown as 32-1, 32-2, 321 or 322; the EZTR40, NRC661A/NRC711 and NRC661 sheets add 323, “Detection temperature abnormality”. NRCP: Er32 “DHW Temperature Sensor Open or Short” (NRCP1112/NRCP982) or “Hot Water Thermistor Open or Short” (NRCP111/NRCP98). Field Manuals: “Outlet Thermistor Abnormality”.
Technician
6 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, NRCP, Field Manual (models not listed)
9 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; NRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
33“Thermistor-Heat Exchanger Outlet abnormality”
Listed only in Noritz technical documents for service technicians. 2021 EZ sheets: “Thermistor-Primary Heat Exchanger Outlet abnormality”. EZTR40, NRC661A/NRC711 and NRC661 sheets: “Thermistor - Heat Exchanger abnormality” (331, 332). NRCP: Er33 “Heat Exchanger Thermistor Open or Short Circuit”. Field Manual KS-11-0004: “Heat Exchanger Thermistor Abnormailty” (as printed). Field Manual June 2011 uses 33 for “Heat Exchanger Thermostat” (p. 34).
Technician
6 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, NRCP, Field Manual (models not listed)
9 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZ tech sheet FABK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; NRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2; Field Manual KS-11-0004 p. 26
35“Thermistor-Exhaust abnormality”
Listed only in Noritz technical documents for service technicians. Also shown as 35-1 to 35-4 or 351 to 354. NRCP: Er35 “Exhaust thermistor open or short circuit” (NRCP1112/NRCP982) or “Exhaust Thermistor Open or Short” (NRCP111/NRCP98). Field Manual KS-11-0004: “Exhaust Thermistor Abnormality”.
Technician
6 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, NRCP, Field Manual (models not listed)
8 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; NRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2; Field Manual KS-11-0004 p. 26
36“Thermistor-Primary Heat Exchanger Inlet abnormality”
Listed only in Noritz technical documents for service technicians. Only on the 2021 EZ sheets.
TechnicianEZEZ tech sheet FABK080 p. 1; EZ tech sheet FDAK080 p. 1
38“Abnormal Operation; Memory Error on the PCB”
Listed only in Noritz technical documents for service technicians. Shown as Er38. NRCP111/NRCP98 sheet: “Abnormal Operation; Memory Error on the Circuit Board”.
TechnicianNRCPNRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2
39“False Flame Detection”
Listed only in Noritz technical documents for service technicians. Shown as Er39. NRCP111/NRCP98 sheet: “Flame detected after gas valve closure”.
TechnicianNRCPNRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2
40“Gas Leakage is Detected in 10 Minutes, or three times within One Hour (Greater than 5 Seconds Each Time)”
Shown as Er:40. The guide's first instruction: if you smell gas, stop, follow the gas safety instructions on page 4 and call a qualified service technician or the gas utility; Er.40 is a hard lockout (NRCP1112/NRCP982 Owner's Guide Rev. 05/19, p. 39). Technical data sheets: “Gas Leakage”.
TechnicianNRCPNRCP1112/NRCP982 guide p. 39; NRCP111/NRCP98 guide p. 34; NRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2
41“Flow Sensor Abnormality”
Listed only in Noritz technical documents for service technicians; the Field Manual tables do not say which models show it. NRCP heaters use Er41 for a different entry: “Fan Speed Error” (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2) or “Fan Speed Abnormality (Exhaust Blockage)” (NRCP111/NRCP98 Technical Data Sheet Rev. 07/19, p. 2). The EZ/NRCR Owner's Guide Rev. 10/25 mentions 41 only in its instructions for draining the heater, where it says 11 or 41 may appear and is not a malfunction (p. 25).
TechnicianField Manual (models not listed)Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
42“Water Flow Sensor (Recirculation) abnormality”
Listed only in Noritz technical documents for service technicians. NRCR models only.
TechnicianNRCRNRCR tech sheet FPHK081 p. 1
43“Burner High Limit Switch Abnormality”
Listed only in Noritz technical documents for service technicians. Shown as Er43.
TechnicianNRCPNRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2
44“Recirculation Abnormality”
Shown as Er:44. Checks: recirculation loop length within specification, the return line filter and the pump operation (NRCP1112/NRCP982 Owner's Guide Rev. 05/19, p. 39). The owner's part is the filter: the same guide's maintenance section covers cleaning the cold water inlet filter and recirculation water filter (NRCP1112/NRCP982 Owner's Guide Rev. 05/19, p. 36), while its safety section says not to service the heater yourself (p. 6). NRCP111/NRCP98 Owner's Guide Rev. 05/19 uses Er:44 for “Possible pump failure”, with the single action “Check pump.” (p. 34).
Owner checks, then technicianNRCPNRCP1112/NRCP982 guide p. 39; NRCP1112/NRCP982 data sheet p. 2
45“Water leakage is detected in water heater.”
Shown as Er:45. The owner's part is pressing the Power button to clear the code; the next check, “Check for the water in the bottom of the heater inside the case.”, is inside the cabinet, and the action ends: “If you have confirmed the water leak, the water valve/gas valve closes and contact the installer or Noritz America Technical Support for assistance.” (NRCP1112/NRCP982 Owner's Guide Rev. 05/19, p. 39). The data sheets for service technicians call it “Water Leak” (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2).
Owner checks, then technicianNRCPNRCP1112/NRCP982 guide p. 39; NRCP111/NRCP98 guide p. 34
46“Low recirculation flow”
Shown as Er 46, on NRCP111 and NRCP98 models only. Checks: return and cold water filters, recirculation loop length, pump operation and the recirculation setting (NRCP111/NRCP98 Owner's Guide Rev. 05/19, p. 34). The owner's part is the filters, covered in the same guide's maintenance section (NRCP111/NRCP98 Owner's Guide Rev. 05/19, p. 31).
Owner checks, then technicianNRCPNRCP111/NRCP98 guide p. 34; NRCP111/NRCP98 data sheet p. 2
50“Extended Continuous Flow Detected”
Listed only in Noritz technical documents for service technicians. The sheets say it is kept only in the error code history, does not indicate a water heater malfunction and appears when flow is detected for 24 hours in a row; the remedy column says to check whether any water is leaking (EZ Technical Sheet FPFK081, p. 1).
TechnicianEZEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1
51“Failure of Gas Solenoid Valve (or Gas Solenoid Valve drive circuit abnormality)”
Listed only in Noritz technical documents for service technicians. Also shown as 511, with 51 on the remote. Field Manual KS-11-0004: “Gas Solenoid Value Error” (as printed).
TechnicianEZTR40, NRC661A/NRC711, NRC661, Field Manual (models not listed)EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; Field Manual KS-11-0004 p. 26
56“CCP Valve Abnormality”
Listed only in Noritz technical documents for service technicians; the Field Manual tables do not say which models show it. The remedy refers to CCP valves working with a System Controller.
TechnicianField Manual (models not listed)Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
59“Combustion Abnormality”
Listed only in Noritz technical documents for service technicians; the Field Manual tables do not say which models show it. Remedies: flue blockage and gas pressure.
TechnicianField Manual (models not listed)Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
60“Hot Water Temperature Abnormality”
Listed only in Noritz technical documents for service technicians. Shown as Er60.
TechnicianNRCPNRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2
61“Fan Motor abnormality”
Listed only in Noritz technical documents for service technicians. Also shown as 61-1 or 61-4 (2025 EZ sheet), 611 or 614 (2024 EZ sheet) and 611, 612 or 614 (EZTR40, NRC661A/NRC711 and NRC661 sheets, where the remote shows 61). On NRCP heaters Er61 reads “RPM Sensor” (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2; NRCP111/NRCP98 Technical Data Sheet Rev. 07/19, p. 2).
Technician
5 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, Field Manual (models not listed)
7 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
63“Recirculation abnormality (No recirculation flow)”
What to check
Among NRCR guides only the 2021 edition lists 63 (NRCR Owner's Guide Rev. 04/21, p. 19); the 2024 and 2025 guides give the same checks under 06 (EZ/NRCR Owner's Guide Rev. 10/25, p. 31). NRCR Technical Sheet FPHK081: “Recirculation Abnormality (No recirculation flow)”, with pump checks (p. 1). The Field Manuals list 63 as “Recirculation Pump Error” in tables that do not say which models show it (Field Manual KS-11-0004, p. 26; Field Manual June 2011, p. 34).
Owner checks, then technicianNRCRNRCR guide 04/21 p. 19; NRCR tech sheet FPHK081 p. 1
65“Water Servo abnormality”
Listed only in Noritz technical documents for service technicians. 2021 EZ sheets: “Water Servo-Main abnormality”. Field Manuals: “Main Water Control Valve”. On NRCP heaters Er65 reads “Water Adjustment Valve Abnormality” (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2) or “Water Control Valve Abnormality” (NRCP111/NRCP98 Technical Data Sheet Rev. 07/19, p. 2).
TechnicianEZ, Field Manual (models not listed)
5 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZ tech sheet FABK080 p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
66“Water Servo-Bypass abnormality”
Listed only in Noritz technical documents for service technicians. Among EZ documents, only the 2021 sheets list it. Field Manuals: “Bypass Water Control Valve”. On NRCP heaters Er66 reads “Mixing Valve Abnormality” (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2) or “Water Mixing Valve Abnormality” (NRCP111/NRCP98 Technical Data Sheet Rev. 07/19, p. 2).
TechnicianEZ, Field Manual (models not listed)EZ tech sheet FABK080 p. 1; EZ tech sheet FDAK080 p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
67“AGM Abnormality”
Listed only in Noritz technical documents for service technicians. Shown as Er67.
TechnicianNRCPNRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2
70“Circuit Board abnormality”
Listed only in Noritz technical documents for service technicians. Also shown as 70 followed by a digit (70-#, 70# or 70*). NRCP: Er70 “Micom Error on PCB Abnormality” (NRCP1112/NRCP982) or “Circuit Board Abnormality” (NRCP111/NRCP98).
Technician
6 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, NRCP, Field Manual (models not listed)
9 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; NRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
71“Gas Valve drive circuit abnormality”
Listed only in Noritz technical documents for service technicians. Also shown with a third digit (71-1, 71-2, 71-4; 711, 712, 714; 71#). EZTR40, NRC661A/NRC711 and NRC661 sheets: “Gas Solenoid Valve drive circuit abnormality; Circuit Board abnormality”. Field Manuals: “Gas Solenoid Valve Abnormality”.
Technician
5 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, Field Manual (models not listed)
7 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
72“Flame Rod circuit abnormality”
Listed only in Noritz technical documents for service technicians. The sheets describe it as detection of flame when no flame is present. Field Manuals: “Flame Rod Abnormality”. On NRCP heaters Er72 reads “Flame Detected before Ignite Abnormality” (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2) or “Flame detected before gas valve opens” (NRCP111/NRCP98 Technical Data Sheet Rev. 07/19, p. 2), and the NRCP1112/NRCP982 Owner's Guide Rev. 05/19 names Er.72 only in its list of hard-lockout codes (p. 39).
Technician
5 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, Field Manual (models not listed)
7 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
73“Circuit Board setting abnormality (Improper Maintenance Writers settings or gas type setting, etc.)”
Listed only in Noritz technical documents for service technicians. The 2025 EZ sheet says it appears when a connector is plugged in or unplugged with the power on and is reset by disconnecting and reconnecting power (EZ Technical Sheet FPFK081, p. 1). EZ Installation Manual Rev. 10/25 says the heater stops with 73 or 731 if a required vent setting is not selected (p. 22); EZTR40 Installation Manual Rev. 11/20 says changing the DIP switch with power connected brings up 733 (p. 12). 2021 EZ sheets: “(Improper Maintenance Writers Settings, DIP Switch Settings, etc.)”. EZTR40, NRC661A/NRC711 and NRC661 sheets: 731, 733 and 734. Field Manuals: “Improper Circuit Board Setting”. On NRCP heaters Er73 reads “DIP Switch Setting Abnormality” (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2).
Technician
5 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, Field Manual (models not listed)
10 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZ tech sheet FABK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34; EZ install manual 10/25 p. 22; EZTR40 install manual p. 12
74“BLE connection error”
Listed only in Noritz technical documents for service technicians. Kept only in the error code history (EZ Technical Sheet FPFK081, p. 1).
TechnicianEZEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1
76“Communication Error between Front Panel and Main PCB”
Listed only in Noritz technical documents for service technicians. Shown as Er76. NRCP111/NRCP98 sheet: “Communication Error between Circuit Board and Control Panel”. On 2021 EZ heaters set for a common duct the multi-system error shows as 76 (EZ Technical Sheet FABK080, p. 1), see F76; on EZTR40, NRC661A/NRC711 and NRC661 heaters the remote shows 76 for 768.
TechnicianNRCPNRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2
F76“Multi-system communication error”
What to check
Listed only in Noritz technical documents for service technicians. EZ Technical Sheet FABK080 prints (F)76 and says 76 is displayed only when a common duct is set (p. 1). Field Manuals: (F) 76 “Multi-System Communication Error”.
TechnicianEZ, Field Manual (models not listed)
6 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZ tech sheet FABK080 p. 1; EZ tech sheet FDAK080 p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
78“Cascade Communication Error”
Listed only in Noritz technical documents for service technicians. Shown as Er78. NRCP111/NRCP98 sheet: “Communication Error (Quick Connect)”.
TechnicianNRCPNRCP1112/NRCP982 data sheet p. 2; NRCP111/NRCP98 data sheet p. 2
79“Circuit Board abnormality”
Listed only in Noritz technical documents for service technicians. NRCR models only; the remedy column names a failure of the circuit board's pump control circuit.
TechnicianNRCRNRCR tech sheet FPHK081 p. 1
90“(1) [When supplying combustion air from the indoors] The air supply vent may be clogged. (2) Exhaust vent may be clogged. (3) Abnormal combustion, low gas supply pressure. (4) Condensate drain line may be clogged.”
What to check
Quoted from the EZ/NRCR Owner's Guide Rev. 10/25, which prints 90, 901 and 902 in this row (p. 31); the 2024 guide prints 90, 901 and 908 (EZ/NRCR Owner's Guide Rev. 01/24, p. 25). Other guides list fewer causes. NRC98, 2017 NRC111, NERC, NRC83 and NRC1111: causes (1) and (3) (NRC98 Owner's Guide Rev. 01/17, p. 28; NRC83/NRC98 Owner's Guide Rev. 03/13, p. 27). NR98 (2020) and NR981: “[NR981-SV] The air inlet filter may be clogged.” and cause (3) (NR98 Owner's Guide Rev. 11/20, p. 26; NR981 Owner's Guide Rev. 03/13, p. 27). NR83, NR71DVC, NR50/NR66/NR71, NR111, 2009 NR98 and 2009 NRC111: only “Abnormal combustion, low gas supply pressure” (NR83 Owner's Guide Rev. 11/20, p. 25; NR50/NR66/NR71 Owner's Guide Rev. 01/11, p. 26; NRC111 Owner's Guide Rev. 09/09, p. 27). On EZTR40, NRC661A/NRC711, NRC661, NR501/NR662 and NER66OD heaters the display shows 901, 902, 903 or 908 and the optional remote shows 90 (EZTR40 Owner's Guide Rev. 01/17, p. 24). EZ technical sheets: “Combustion abnormality (Unit shuts off)”.
Owner checks, then technicianEZ, NRCR
5 documentsEZ/NRCR guide 10/25 p. 31; EZ/NRCR guide 01/24 p. 25; EZ guide SBB8163-2 p. 18; EZ guide SBB80T9-2 p. 28; NRCR guide 04/21 p. 20
901“Abnormal combustion. The air inlet filter may be clogged.”
Quoted from the EZTR40 guide, where 901, 903 and 908 share one row (EZTR40 Owner's Guide Rev. 01/17, p. 24); its technical sheet shows a warning first, “Combustion abnormality (Warning indication)”, then “(Unit shuts off)” (EZTR40 Technical Sheet EXSK072, p. 1). Other models give 901 a different cause. NRC661A/NRC711 and NRC661: “Abnormal combustion. [When supplying combustion air from the indoors] The air supply vent may be clogged.” (NRC661A/NRC711 Owner's Guide Rev. 01/17, p. 25; NRC661 Owner's Guide Rev. 01/13, p. 25). NR501/NR662 and NER66OD: “Abnormal combustion.” (NR501/NR662 Owner's Guide Rev. 01/17, p. 24; NER66OD Owner's Guide Rev. 11/19, p. 24). EZ and NRCR: 901 shares the four-cause 90 row (EZ/NRCR Owner's Guide Rev. 10/25, p. 31; EZ/NRCR Owner's Guide Rev. 01/24, p. 25), and the 2025 EZ sheet writes it 90-1.
Owner checks, then technicianEZTR40EZTR40 guide p. 24; EZTR40 tech sheet p. 1
902“Abnormal combustion, low gas supply pressure.”
The action is to have a professional check the gas supply pressure and contact the nearest Noritz agent (EZTR40 Owner's Guide Rev. 01/17, p. 24). EZ and NRCR: 902 shares the four-cause 90 row (EZ/NRCR Owner's Guide Rev. 10/25, p. 31), and the 2025 EZ sheet writes it 90-2.
TechnicianEZTR40, NRC661A/NRC711, NRC661, NR501/NR662/NER66
6 documentsEZTR40 guide p. 24; NRC661A/NRC711 guide p. 25; NRC661 guide p. 25; NR501/NR662 guide p. 24; NER66OD guide p. 24; EZTR40 tech sheet p. 1
903“Abnormal combustion. The air inlet filter may be clogged.”
What to check
Quoted from the EZTR40 guide (EZTR40 Owner's Guide Rev. 01/17, p. 24); its technical sheet calls it “Combustion abnormality (Unit shuts off)” (EZTR40 Technical Sheet EXSK072, p. 1). The optional remote shows 90. Other models give 903 a different cause. NRC661A/NRC711 and NRC661: “Abnormal combustion. [When supplying combustion air from the indoors] The air supply vent may be clogged.” (NRC661A/NRC711 Owner's Guide Rev. 01/17, p. 25; NRC661 Owner's Guide Rev. 01/13, p. 25). NR501/NR662 and NER66OD: “Abnormal combustion.” (NR501/NR662 Owner's Guide Rev. 01/17, p. 24; NER66OD Owner's Guide Rev. 11/19, p. 24).
Owner checks, then technicianEZTR40EZTR40 guide p. 24; EZTR40 tech sheet p. 1
908“Abnormal combustion. The air inlet filter may be clogged.”
Quoted from the EZTR40 guide (EZTR40 Owner's Guide Rev. 01/17, p. 24); its technical sheet says the unit is locked and to contact the nearest Noritz agent to reset it (EZTR40 Technical Sheet EXSK072, p. 1). Other models give 908 a different cause. NRC661A/NRC711: “Abnormal combustion. [When supplying combustion air from the indoors] The air supply vent may be clogged.” (NRC661A/NRC711 Owner's Guide Rev. 01/17, p. 25). NR501/NR662 and NER66OD: “Abnormal combustion.” (NR501/NR662 Owner's Guide Rev. 01/17, p. 24; NER66OD Owner's Guide Rev. 11/19, p. 24). The NRC661 guide does not list 908; its technical sheet does (NRC661 Technical Sheet EVRK072, p. 1). EZ and NRCR: 908 shares the four-cause 90 row in the EZ/NRCR Owner's Guide Rev. 01/24 (p. 25); the EZ sheets say a lockout has been activated (EZ Technical Sheet FPFK081, p. 1).
Owner checks, then technicianEZTR40EZTR40 guide p. 24; EZTR40 tech sheet p. 1
91“Gas conversion has not been performed correctly.”
The 2024 and 2025 EZ/NRCR guides say to contact the installer (EZ/NRCR Owner's Guide Rev. 10/25, p. 31); the 2021 EZ guides do not list 91. A gas conversion kit must be installed by a qualified installer, service agency or the gas supplier (EZ/NRCR Owner's Guide Rev. 10/25, p. 4). The technical sheets use other wording: “May be improper gas type” (EZ Technical Sheet FPFK081, p. 1) and “Improper gas type” on the EZTR40, NRC661A/NRC711 and NRC661, where 91 appears only in the technical sheets (EZTR40 Technical Sheet EXSK072, p. 1).
TechnicianEZ, NRCREZ/NRCR guide 10/25 p. 31; EZ/NRCR guide 01/24 p. 25
92“The neutralizer needs to be replaced soon.”
The guide says the heater can be used for a while with a reduced maximum hot water flow, and to contact the installer or Noritz America Technical Support (NRC111 Owner's Guide Rev. 09/09, p. 27). Field Manual June 2011: “Neutralizer Life Cycle Warning”.
TechnicianNRC111 (2009)NRC111 guide 09/09 p. 27; Field Manual 06/2011 p. 34
93“The neutralizer has reached the end of its service life and must be replaced.”
The guide says the heater cannot be used, and to contact the installer or Noritz America Technical Support (NRC111 Owner's Guide Rev. 09/09, p. 27). Field Manual June 2011: “Neutralizer Life Cycle End”.
TechnicianNRC111 (2009)NRC111 guide 09/09 p. 27; Field Manual 06/2011 p. 34
94“Exhaust temperature is too high”
Wording of the EZ, EZTR40, NRC661A/NRC711 and NRC661 technical sheets (also shown as 94-1, 94-2 or 941, 942). The EZTR40 Owner's Guide adds “*941 Warning indication. - The unit will continue to operate.”, shows 941 or 942 on the unit and 94 on the optional remote, and says to contact the nearest Noritz agent (EZTR40 Owner's Guide Rev. 01/17, p. 24); EZTR40 Technical Sheet EXSK072 lists 941 as a warning and 942 as “Unit shuts off” (p. 1). Other owner's guides do not list 94. On NRCP heaters Er94 is “Exhaust Overheating (The water heater shuts down when the flue temperature exceed 149°F(65°C))” (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2; NRCP111/NRCP98 Technical Data Sheet Rev. 07/19, p. 2). Field Manual KS-11-0004 calls it “High Exhaust temperature” (p. 26).
TechnicianEZ, EZTR40, NRC661A/NRC711, NRC661
7 documentsEZTR40 guide p. 24; EZTR40 tech sheet p. 1; EZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZ tech sheet FABK080 p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1
99“Abnormal combustion”
The guides say to contact the nearest Noritz agent; NRC111 Owner's Guide Rev. 09/09 says to contact the installer or Noritz America Technical Support (p. 27). On EZ and NRCR heaters only the 2021 guides list 99. EZTR40, NRC661A/NRC711 and NRC661 sheets: “Combustion abnormality (Unit is locked)”, with “To reset this error code, contact the nearest NORITZ agent.” (EZTR40 Technical Sheet EXSK072, p. 1). Field Manuals: “Combustion Abnormality (Unit shuts off)”.
Technician
11 seriesEZ, NRCR, EZTR40, NRC661A/NRC711, NRC661, NRC98/NRC111/NERC, NRC (2013), NRC111 (2009), NR98/NR83/NR71DVC, NR501/NR662/NER66, NR (2009–2013)
13 documentsEZ guide SBB8163-2 p. 18; EZ guide SBB80T9-2 p. 28; NRCR guide 04/21 p. 20; EZTR40 guide p. 24; NRC661A/NRC711 guide p. 25; NRC661 guide p. 25; NRC98 guide 01/17 p. 28; NRC83/NRC98 guide 03/13 p. 27; NRC111 guide 09/09 p. 27; NR98 guide 11/20 p. 26; NR501/NR662 guide p. 24; NR50/NR66/NR71 guide p. 26; EZTR40 tech sheet p. 1
410“Multi-System Flow Imbalance Error”
Listed only in Noritz technical documents for service technicians; the Field Manual tables do not say which models show it.
TechnicianField Manual (models not listed)Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
760“Remote Controller transmission abnormality”
Listed only in Noritz technical documents for service technicians. The 2024 and 2025 EZ sheets say it is kept only in the error code history. On EZTR40, NRC661A/NRC711 and NRC661 heaters the remote shows 760 while the heater's display shows nothing (EZTR40 Technical Sheet EXSK072, p. 1).
Technician
5 seriesEZ, EZTR40, NRC661A/NRC711, NRC661, Field Manual (models not listed)
8 documentsEZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZ tech sheet FABK080 p. 1; EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34
768“Display Window transmission abnormality”
Listed only in Noritz technical documents for service technicians. The remote shows 76.
TechnicianEZTR40, NRC661A/NRC711, NRC661EZTR40 tech sheet p. 1; NRC661A/NRC711 tech sheet p. 1; NRC661 tech sheet p. 1
C1#“Descaling Reminder (Notice for periodic maintenance)”
# is a digit from 1 to 9. The 2021 and 2024 guides call it “Service Reminder”. The reminder is off by default, and the customer or installer turns it on (EZ Installation Manual Rev. 10/25, p. 44). To clear it the heat exchanger must be flushed, a procedure written for a qualified service professional or authorized Noritz service representative (EZ Installation Manual Rev. 10/25, p. 69).
TechnicianEZ, NRCR
6 documentsEZ/NRCR guide 10/25 p. 32; EZ/NRCR guide 01/24 p. 26; EZ guide SBB8163-2 p. 18; EZ guide SBB80T9-2 p. 28; NRCR guide 04/21 p. 20; EZ install manual 10/25 p. 44
C*#“The unit detects Scale Build-up in the Heat Exchanger. (Warning indication, and then the unit will shut off before long.)”
* is 1 to 4 or F; # is 1 to 9 or A, b, C, d, E, F, and the remote shows C1 to C4 (EZTR40 Owner's Guide Rev. 01/17, p. 24). The NRC98, NRC111, NERC, NR98, NR83 and NR71DVC guides give # as 0 to 9. The guides say the heater may shut off and lock, that it can run temporarily if electrical power is disconnected until the heat exchanger can be flushed, and to contact Noritz America about flushing (NRC98 Owner's Guide Rev. 01/17, p. 28).
Owner checks, then technician
5 seriesEZTR40, NRC661A/NRC711, NRC98/NRC111/NERC, NR98/NR83/NR71DVC, NR501/NR662/NER66
10 documentsEZTR40 guide p. 24; NRC661A/NRC711 guide p. 25; NRC98 guide 01/17 p. 28; NRC111 guide 01/17 p. 28; NERC98DV guide p. 28; NR98 guide 11/20 p. 26; NR83 guide p. 25; NR71DVC guide p. 25; NR501/NR662 guide p. 24; NER66OD guide p. 24
CF#“The unit detects the Scale Build-up in the Heat Exchanger many times (The unit is locked.)”
The heater is locked after repeated scale codes; the heat exchanger must be flushed, and the guides say to contact Noritz America before flushing (NRC98 Owner's Guide Rev. 01/17, p. 28).
Technician
5 seriesEZTR40, NRC661A/NRC711, NRC98/NRC111/NERC, NR98/NR83/NR71DVC, NR501/NR662/NER66
10 documentsEZTR40 guide p. 24; NRC661A/NRC711 guide p. 25; NRC98 guide 01/17 p. 28; NRC111 guide 01/17 p. 28; NERC98DV guide p. 28; NR98 guide 11/20 p. 26; NR83 guide p. 25; NR71DVC guide p. 25; NR501/NR662 guide p. 24; NER66OD guide p. 24
Flashing lamp“Unit abnormality”
NR71-SV and NR71-OD only: a lamp on the heater flashes instead of a number, for any unit abnormality. The guide says to check whether the gas valve is open, then close the hot water fixture and open it again; if the lamp does not start flashing again, the problem is solved (NR50/NR66/NR71 Owner's Guide Rev. 01/11, p. 26). Field Manual June 2011 has a separate flash-count table for NR71 heaters without a remote (p. 35).
Owner checks, then technicianNR (2009–2013)NR50/NR66/NR71 guide p. 26
Two flashing symbols“The outlet temperature is colder than set temperature.”
Our description of a pictogram: the display shows two flashing symbols and no digits. The guide's action is to contact the nearest Noritz agent (EZTR40 Owner's Guide Rev. 01/17, p. 24).
TechnicianEZTR40, NRC661A/NRC711, NRC661, NR501/NR662/NER66
5 documentsEZTR40 guide p. 24; NRC661A/NRC711 guide p. 25; NRC661 guide p. 25; NR501/NR662 guide p. 24; NER66OD guide p. 24
Three flashing symbols“The indication on the display window shown is not an error of unit. If you try to supply a low flow of water when the inlet water temperature is high, hot water is not supplied sometimes (combustion is automatically stopped and the temperature of outlet water does not become hot).”
Our description of a pictogram: the display shows three flashing symbols and no digits. Not an error, and the guides give no action (EZTR40 Owner's Guide Rev. 01/17, p. 24). NRC661 Owner's Guide Rev. 01/13 ends the sentence with “the temperature of hot water does not become hot” (p. 25).
Owner can checkEZTR40, NRC661A/NRC711, NRC661, NR501/NR662/NER66
5 documentsEZTR40 guide p. 24; NRC661A/NRC711 guide p. 25; NRC661 guide p. 25; NR501/NR662 guide p. 24; NER66OD guide p. 24

What to check, code by code

Noritz 11 (ignition failure): what to check

Checked

Noritz display

11

“Ignition failure”

Owner checks, then technician

Printed on 12 model series · 11 documents

EZ, NRCR, EZTR40, NRC661A/NRC711, NRC661, NRC98/NRC111/NERC, NRC (2013), NRC111 (2009), NRCP, NR98/NR83/NR71DVC, NR501/NR662/NER66, NR (2009–2013) · EZ/NRCR guide 10/25 p. 31; EZTR40 guide p. 24; NRC661A/NRC711 guide p. 25; NRC661 guide p. 25; NRC98 guide 01/17 p. 28; NRC83/NRC98 guide 03/13 p. 26; NRC111 guide 09/09 p. 27; NRCP1112/NRCP982 guide p. 39; NR98 guide 11/20 p. 26; NR501/NR662 guide p. 24; NR50/NR66/NR71 guide p. 26

“Ignition error” in EZ Owner's Guide SBB80T9-2 (p. 28) and in the EZTR40, NRC, NERC, NR and NER66OD guides. NRCP heaters show Er:11, “Ignition has Failed 10 (Ten) Times” (NRCP1112/NRCP982 Owner's Guide Rev. 05/19, p. 39). Technical sheets: “Ignition failure (Initial flame fault detection)”.

Short answer Noritz code 11 means ignition failure: the heater tried to light the burner and failed. Check that the gas valve to the heater is open, reset the heater as your owner's guide describes, and contact Noritz America if 11 comes back. See what to check

What it means

Code 11 means the heater tried to light the burner and failed. The EZ/NRCR, EZTR40 and NRCP guides say the heater has no pilot: an ignition device lights the burner, and you should not try to light it by hand (EZ/NRCR Owner’s Guide Rev. 10/25, p. 3; EZTR40 Owner’s Guide Rev. 01/17, p. 3; NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 4).

The 10/25 guide’s troubleshooting section lists a related symptom, “The water heater attempts to ignite but fails”: reset the heater and try again, since there may be air in the gas line, and have a professional check the gas supply pressure (EZ/NRCR Owner’s Guide Rev. 10/25, p. 28).

Every Noritz owner’s guide we use lists a gas valve check for 11. The reset that follows differs by model.

Check these first

  1. Check that the gas valve to the heater is open (EZ/NRCR Owner’s Guide Rev. 10/25, p. 31; EZTR40 Owner’s Guide Rev. 01/17, p. 24; NRC98 Owner’s Guide Rev. 01/17, p. 28). Turn the knob by hand only. If it will not turn by hand, do not force it or use tools; call a qualified service technician (EZ/NRCR Owner’s Guide Rev. 10/25, p. 3).
  2. Reset the heater the way your guide describes:
    • EZ and NRCR heaters covered by the 01/24 and 10/25 guides: close the hot water fixture and open it again, or turn the POWER button or Power switch off and then on (EZ/NRCR Owner’s Guide Rev. 10/25, p. 31; EZ/NRCR Owner’s Guide Rev. 01/24, p. 25).
    • EZ and NRCR heaters covered by the 04/21 guides, and NRC98, NRC111, NERC, NRC83, NRC1111, NR98, NR83, NR71DVC and the 2009–2013 NR models: turn the heater off with its power button, open a hot water fixture, then turn the heater back on (EZ Owner’s Guide SBB8163-2, p. 18; NRC98 Owner’s Guide Rev. 01/17, p. 28; NR98 Owner’s Guide Rev. 11/20, p. 26).
    • EZTR40, NRC661A/NRC711, NRC661, NR501/NR662 and NER66OD: unplug the heater or press the power button on the optional remote controller, open a hot water fixture, then turn the heater back on (EZTR40 Owner’s Guide Rev. 01/17, p. 24).
    • NRCP: press the Power button to clear Er:11. It is a hard lockout, which clears when Power is pressed off and then on (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 39).
  3. If the number does not come back, the guides treat the problem as solved (EZ/NRCR Owner’s Guide Rev. 10/25, p. 31).
  4. If an error code is indicated again after these actions, the guides say to contact Noritz America (EZ/NRCR Owner’s Guide Rev. 10/25, p. 32; EZTR40 Owner’s Guide Rev. 01/17, p. 24); the NRCP guides say to contact the installer or Noritz America Technical Support (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 39). Technical Support is at 1-866-766-7489 (EZ/NRCR Owner’s Guide Rev. 10/25, p. 32).

When to call a licensed technician

  • 11 is indicated again after the guide’s actions (EZ/NRCR Owner’s Guide Rev. 10/25, p. 32).
  • Gas supply pressure and the gas line. Noritz leaves the pressure check to a professional (EZ/NRCR Owner’s Guide Rev. 10/25, p. 28), and sizing and installing the gas system is the installer’s responsibility (EZ Installation Manual Rev. 10/25, p. 36). The installation manuals give the supply pressure range: 3.5–10.5 in. W.C. for natural gas and 8–13 in. W.C. for propane for the EZ models in the 10/25 manual (EZ Installation Manual Rev. 10/25, p. 38), and 4–10.5 and 8–14 in. W.C. on the EZTR40 (EZTR40 Installation Manual Rev. 11/20, p. 16). The EZ manual warns that pressure below the minimum may result in ignition failure, injury or death (EZ Installation Manual Rev. 10/25, p. 38).
  • Parts inside the heater. Noritz’s sheet for service technicians lists the checks: gas supply piping and pressure, igniter spark, gas valve, flame rod and the ground connection to the circuit board (EZ Technical Sheet FPFK081, p. 1).

Notes for different models

On NRCP heaters the code reads Er:11, “Ignition has Failed 10 (Ten) Times” (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 39; NRCP111/NRCP98 Owner’s Guide Rev. 05/19, p. 34).

NR71-SV and NR71-OD heaters without a remote flash a lamp instead of showing a number, for any unit abnormality, not only an ignition failure. The guide’s steps for the lamp are the same gas valve check, then closing and reopening the hot water fixture (NR50/NR66/NR71 Owner’s Guide Rev. 01/11, p. 26).

In its instructions for draining the heater, the EZ/NRCR Owner’s Guide Rev. 10/25 says 11 or 41 may appear on the operation panel, that this is not a malfunction, and not to turn the power off (p. 25).

Related codes: 12, 90, 902. All Noritz codes

Noritz 29 (condensate drain or air pressure switch): what to check

Checked

Noritz display

29

“Clogging of condensate trap or drain pipe”

Owner checks, then technician

Printed on 5 model series · 9 documents

EZTR40, NRC661A/NRC711, NRC661, NRC98/NRC111/NERC, NRC (2013) · NRC98 guide 01/17 p. 28; NRC111 guide 01/17 p. 28; NERC98DV guide p. 28; NERC11DV guide p. 28; NRC83/NRC98 guide 03/13 p. 26; NRC1111 guide p. 27; EZTR40 guide p. 24; NRC661A/NRC711 guide p. 25; NRC661 guide p. 25

Other models use 29 for other faults. NRCP (Er:29): “Air Pressure Switch Abnormality” (NRCP1112/NRCP982 Owner's Guide Rev. 05/19, p. 39; NRCP111/NRCP98 Owner's Guide Rev. 05/19, p. 34). NRC111 Owner's Guide Rev. 09/09: “Clogging of neutralizer” (p. 27). EZ technical sheets: “External Condensate Pump abnormality”, shown only if an external condensate pump is interlocked with the heater (EZ Technical Sheet FPFK081, p. 1), and “Condensate pump abnormality (Only if connected to the water heater)” (EZ Technical Sheet FHCK080, p. 1). EZTR40, NRC661A/NRC711 and NRC661 sheets: “Condensate Container clogging” (EZTR40 Technical Sheet EXSK072, p. 1). Field Manual KS-11-0004: “Neutralizer Water Level Electrode Abnormality” (p. 26).

Short answer On Noritz NRC98, NRC83, NRC1111, NERC, NRC661, NRC661A/NRC711, EZTR40 and 2017 NRC111 heaters, code 29 means clogging of the condensate trap or drain pipe; other models use 29 differently. Check whether the condensate drain pipe is clogged or frozen, then contact the installer. See what to check

What it means

What 29 means depends on the model:

  • NRC98, 2017 NRC111, NERC, NRC83, NRC1111, EZTR40, NRC661A/NRC711 and NRC661: clogging of the condensate trap or drain pipe (NRC98 Owner’s Guide Rev. 01/17, p. 28; EZTR40 Owner’s Guide Rev. 01/17, p. 24).
  • NRC111-SV and NRC111-DV from 2009: clogging of the neutralizer (NRC111 Owner’s Guide Rev. 09/09, p. 27).
  • NRCP: Er:29, an air pressure switch abnormality (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 39).
  • EZ and NRCR: 29 is not in the owner’s guides. Noritz’s technical sheet lists it as an external condensate pump abnormality that shows only if such a pump is interlocked with the heater (EZ Technical Sheet FPFK081, p. 1).

The EZTR40 guide says condensate drains from the drain pipe at up to about 0.8 gallons per hour (3 liters per hour), that this is not a water leak, and that the condensate is acidic, with a pH of about 2–3 (EZTR40 Owner’s Guide Rev. 01/17, p. 8).

Check these first

NRC98, 2017 NRC111, NERC, NRC83, NRC1111, EZTR40, NRC661A/NRC711 and NRC661 heaters:

  1. Check whether the condensate drain pipe is clogged or frozen (NRC98 Owner’s Guide Rev. 01/17, p. 28; EZTR40 Owner’s Guide Rev. 01/17, p. 24). Do not plug or block the drain line; it must always drain freely (EZTR40 Owner’s Guide Rev. 01/17, p. 8). The EZTR40 guide’s periodic inspection also asks you to check for blockage at the drain pipe discharge (EZTR40 Owner’s Guide Rev. 01/17, p. 21).
  2. If the heater has been out of use for a long time, the condensate trap has to be filled with water to keep dangerous exhaust gases out of the building. The EZTR40 guide fills it this way: make sure the area is well ventilated, opening a window or door if needed, then run the heater and check that condensate comes out of the drain pipe. In normal use that starts within 15 minutes, though it can take longer (EZTR40 Owner’s Guide Rev. 01/17, p. 20).
  3. The guide’s next step is to contact the installer or Noritz America Technical Support for assistance (NRC98 Owner’s Guide Rev. 01/17, p. 28). The NERC98DV and NERC11DV guides name Thermalux Customer Care instead (NERC98DV Owner’s Guide Rev. 11/19, p. 28).

NRCP heaters (Er:29):

  1. Press the Power button to clear the code. Er.29 is a hard lockout, which clears when Power is pressed off and then on (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 39; NRCP111/NRCP98 Owner’s Guide Rev. 05/19, p. 34).
  2. If the code is still there, make sure the exhaust pipe is free of obstructions and that the condensate trap and drain pipe are not clogged (NRCP111/NRCP98 Owner’s Guide Rev. 05/19, p. 34).
  3. The same row also lists cleaning the intake air filter. That filter sits behind the front cover: the guides’ procedure starts with turning the heater off, disconnecting its power and removing four front cover screws (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 35; NRCP111/NRCP98 Owner’s Guide Rev. 05/19, p. 30). The same guides also say not to install, repair or service the heater yourself and not to disassemble it (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, pp. 6, 10; NRCP111/NRCP98 Owner’s Guide Rev. 05/19, pp. 5–6). Because the step opens the cabinet of a gas appliance, we list it as technician work.
  4. If Er:29 happens again, contact the installer or Noritz America Technical Support (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 39).

When to call a licensed technician

  • No water comes out of the end of the drain line. A qualified service technician must clean the condensate line (EZTR40 Owner’s Guide Rev. 01/17, p. 20).
  • The NRCP intake air filter, which sits behind the front cover (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 35).
  • The drain line itself. The EZTR40 installation manual says horizontal runs must slope 1/4 in. per foot toward the drain or condensate pump, the line must not have a trap, and an external neutralizer must be installed where local code requires one or where the condensate could cause damage (EZTR40 Installation Manual Rev. 11/20, p. 24).
  • The neutralizer on a 2009 NRC111. The guide says to contact the installer or Noritz America Technical Support; codes 92 and 93 on the same models mean the neutralizer needs replacing soon or has reached the end of its life (NRC111 Owner’s Guide Rev. 09/09, p. 27).
  • An external condensate pump on an EZ heater. The technician’s checks are the pump for blockage and its connector for damage (EZ Technical Sheet FPFK081, p. 1).

Notes for different models

  • On NRCP heaters 29 is an air pressure switch code, yet the NRCP1112/NRCP982 guide’s list of hard-lockout codes labels it “Er.29_Condensate line” (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 39). The NRCP111/NRCP98 data sheet adds a check that the condensate line slopes down (NRCP111/NRCP98 Technical Data Sheet Rev. 07/19, p. 2).
  • The 2024 EZ sheet also lists 293, the 2025 sheet 29-3 (EZ Technical Sheet FHCK080, p. 1; EZ Technical Sheet FPFK081, p. 1). The EZ installation manual has a step to confirm that “External Condensate Pump Triggered 29” appears on the operation panel (EZ Installation Manual Rev. 10/25, p. 49).
  • Field Manual KS-11-0004 (October 2012; NRC83, NRC98, NRC1111, NR981, NR83-DVC) and Field Manual June 2011 call 29 “Neutralizer Water Level Electrode Abnormality” in tables that do not say which models show it (Field Manual KS-11-0004, p. 26; Field Manual June 2011, p. 34).
  • The NR and NER66OD owner’s guides do not list 29.

Related codes: 90, 92, 93. All Noritz codes

Noritz 63 (recirculation abnormality): what to check

Checked

Noritz display

63

“Recirculation abnormality (No recirculation flow)”

Owner checks, then technician

NRCR · NRCR Owner's Guide Rev. 04/21, p. 19; NRCR Technical Sheet FPHK081, p. 1

Among NRCR guides only the 2021 edition lists 63 (NRCR Owner's Guide Rev. 04/21, p. 19); the 2024 and 2025 guides give the same checks under 06 (EZ/NRCR Owner's Guide Rev. 10/25, p. 31). NRCR Technical Sheet FPHK081: “Recirculation Abnormality (No recirculation flow)”, with pump checks (p. 1). The Field Manuals list 63 as “Recirculation Pump Error” in tables that do not say which models show it (Field Manual KS-11-0004, p. 26; Field Manual June 2011, p. 34).

Short answer On Noritz NRCR92DV and NRCR111DV heaters, code 63 means a recirculation abnormality with no recirculation flow. Check the return line filter and the crossover valve's filter; pump and settings checks are technician work. See what to check

What it means

63 is a recirculation code on the NRCR92DV and NRCR111DV. The 2021 NRCR guide calls it “Recirculation abnormality (No recirculation flow)” (NRCR Owner’s Guide Rev. 04/21, p. 19). The 01/24 and 10/25 guides do not list 63 and give the same checks under 06, “Recirculation abnormality” (EZ/NRCR Owner’s Guide Rev. 01/24, p. 25; EZ/NRCR Owner’s Guide Rev. 10/25, p. 31).

Noritz’s technical sheet for the NRCR models of the 10/25 guide keeps both codes. There, 06 is a warning that the heater detects recirculation flow but not enough of it, and 63 means no recirculation flow, with checks on the pump (NRCR Technical Sheet FPHK081, p. 1).

Check these first

  1. Check the return line filter and the crossover valve’s filter (NRCR Owner’s Guide Rev. 04/21, p. 19). The technical sheet marks the crossover valve check for crossover mode only (NRCR Technical Sheet FPHK081, p. 1).
  2. The guide’s maintenance section shows two water drain valves with filters, one in the hot water return and one in the cold water inlet (NRCR Owner’s Guide Rev. 04/21, p. 16; EZ/NRCR Owner’s Guide Rev. 10/25, p. 27). To clean them, turn the heater off and let it cool; close the hot water valve, the water supply valve and the hot water return valve; remove the water drain valves over a bucket, clean each filter with a brush under running water and refit the valves without losing the O-ring; then reopen the three valves and check that the drain valves do not leak (NRCR Owner’s Guide Rev. 04/21, p. 16). About 0.85 gallon (3.2 L) of water drains out (NRCR Owner’s Guide Rev. 04/21, p. 16).
  3. The guide does not say whether that hot water return filter is the “return line filter” of the code table, and it does not name the crossover valve’s filter or say where it is. For other questions the code table says to contact Noritz America; the 2021 guide gives 1-866-766-7489 (NRCR Owner’s Guide Rev. 04/21, pp. 19–20).
  4. On heaters covered by the 10/25 guide, press Menu and select Error History to see the eight most recent failures, “1” being the latest (EZ/NRCR Owner’s Guide Rev. 10/25, p. 20).

When to call a licensed technician

  • The pump. For 63 the technician checks that the pump rotates, the pulse frequency from the pump rotational frequency sensor, the pump connection and the voltage from the circuit board (NRCR Technical Sheet FPHK081, p. 1).
  • Recirculation settings and air in the lines. For 06 the sheet adds checking that the recirculation type in the unit settings is correct and, in dedicated mode, purging the air in the hot water line and return line (NRCR Technical Sheet FPHK081, p. 1).
  • Related NRCR codes on the same sheet: 42, a fault of the recirculation water flow sensor, and 79, a failure of the circuit board’s pump control circuit (NRCR Technical Sheet FPHK081, p. 1).

Notes for different models

  • In the 2021 NRCR guide, 06 means “Low recirculation flow” and is only a warning: the heater keeps running, and the one check listed is the return line filter (NRCR Owner’s Guide Rev. 04/21, p. 19).
  • NRCP heaters use their own codes: Er:44 is “Recirculation Abnormality” on the NRCP1112 and NRCP982 (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 39) and “Possible pump failure” on the NRCP111 and NRCP98, which also have Er 46, “Low recirculation flow” (NRCP111/NRCP98 Owner’s Guide Rev. 05/19, p. 34).
  • Field Manual KS-11-0004 (October 2012; NRC83, NRC98, NRC1111, NR981, NR83-DVC) and Field Manual June 2011 list 63 as “Recirculation Pump Error” in tables that do not say which models show it (Field Manual KS-11-0004, p. 26; Field Manual June 2011, p. 34).

Related codes: 06, 42, 79. All Noritz codes

Noritz F76 code (multi-system communication error): what to do

Checked

Noritz display

F76

“Multi-system communication error”

Technician

EZ, Field Manual (models not listed) · EZ tech sheet FPFK081 p. 1; EZ tech sheet FHCK080 p. 1; EZ tech sheet FABK080 p. 1; EZ tech sheet FDAK080 p. 1; Field Manual KS-11-0004 p. 26; Field Manual 06/2011 p. 34

Listed only in Noritz technical documents for service technicians. EZ Technical Sheet FABK080 prints (F)76 and says 76 is displayed only when a common duct is set (p. 1). Field Manuals: (F) 76 “Multi-System Communication Error”.

Short answer Noritz F76 means a multi-system communication error in a Quick Connect setup. The owner's guides give no steps or reset for it: contact Noritz America Technical Support, and leave the cord and settings checks to a technician. See what to check

What it means

F76 is a communication error in a Noritz Quick Connect multi-system. Every Noritz sheet that lists it starts with the same check, the connection of the Quick Connect Cord (EZ Technical Sheet FPFK081, p. 1; EZ Technical Sheet FABK080, p. 1; Field Manual KS-11-0004, p. 26).

In such a system the letter F also has a second use. The 2024 and 2025 EZ sheets say that in a Quick Connect multi-system with a remote controller, an F before a code number on the remote marks a code from the secondary unit, with F76 as the one exception (EZ Technical Sheet FPFK081, p. 1; EZ Technical Sheet FHCK080, p. 1). The 2021 sheets and the Field Manuals describe the secondary unit as the one without a remote controller (EZ Technical Sheet FABK080, p. 1; Field Manual June 2011, p. 34).

So F11 or F90 is code 11 or 90 on the secondary heater: look up the number without the F, for example code 11 or code 90. F76 does not mean code 76 on the secondary heater. The sheets give it a row of its own.

Check these first

No Noritz owner’s guide lists F76 or 76 in its error table, so the guides give owners no steps and no reset for this code. The 10/25 EZ/NRCR guide covers codes it does not list on its follow-up service page:

  1. Contact Noritz America. The guide lists “any other error code” as a reason to call and gives the Technical Support number, 1-866-766-7489 (EZ/NRCR Owner’s Guide Rev. 10/25, p. 32).
  2. Find the model of the heater. It is on the rating plate or under “Heater Info.” (EZ/NRCR Owner’s Guide Rev. 10/25, p. 32).

When to call a licensed technician

For F76 itself. Noritz gives its checks only on sheets written for service technicians, and the owner’s guide says installation and service must be performed by a qualified installer, service agency or the gas supplier (EZ/NRCR Owner’s Guide Rev. 10/25, p. 4). The checks on the sheets:

  • The Quick Connect Cord connection (EZ Technical Sheet FPFK081, p. 1; EZ Technical Sheet FDAK080, p. 1). The Field Manuals name the Quick-Connect Cord or the Multi-System Controller (Field Manual KS-11-0004, p. 26; Field Manual June 2011, p. 34).
  • On 2024 and 2025 EZ heaters, whether the quick connect type in the unit settings is correct (EZ Technical Sheet FHCK080, p. 1; EZ Technical Sheet FPFK081, p. 1).
  • The reset. The 2024 and 2025 sheets say F76 is reset by disconnecting and reconnecting the power (EZ Technical Sheet FPFK081, p. 1; EZ Technical Sheet FHCK080, p. 1). The 2021 sheets give no reset for it.

Notes for different models

  • 2021 EZ111DV and EZ98DV: unlike the 2024 and 2025 sheets, both 2021 sheets list only the cord check. Sheet FABK080 (GQ-C3259WX-FF US, GQ-C2859WX-FF US) prints the row as “(F)76” and adds “Display “76” error only when setting common duct.” On these heaters the same error shows as 76, without the F, only when the system is set for a common duct (EZ Technical Sheet FABK080, p. 1). Sheet FDAK080 (GQ-C3260WX-FF US, GQ-C2860WX-FF US) prints F76 without that remark (EZ Technical Sheet FDAK080, p. 1).
  • NRCP: Er76 is a different fault, a communication error between the control panel and the circuit board (“Communication Error between Front Panel and Main PCB” in NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2; “Communication Error between Circuit Board and Control Panel” in NRCP111/NRCP98 Technical Data Sheet Rev. 07/19, p. 2). On the NRCP111/NRCP98 sheet (07/19) the Quick Connect code is Er78, “Communication Error (Quick Connect)”, with checks of the QC-NRCP-1 cable connection and the QC setting for both units (NRCP111/NRCP98 Technical Data Sheet Rev. 07/19, p. 2). The NRCP1112/NRCP982 sheet (03/17) lists Er78 as “Cascade Communication Error” (check the communication cable) (NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17, p. 2).
  • EZTR40, NRC661A/NRC711 and NRC661: 76 on the optional remote stands for 768 on the heater’s display, a “Display Window transmission abnormality” (EZTR40 Technical Sheet EXSK072, p. 1; NRC661A/NRC711 Technical Sheet EVPK072, p. 1; NRC661 Technical Sheet EVRK072, p. 1). These sheets have no F76 row. The EZTR40 guide does not list 768 and says to contact Noritz America if any other error code appears (EZTR40 Owner’s Guide Rev. 01/17, p. 24).
  • Field Manual KS-11-0004 (October 2012) and Field Manual June 2011: “(F) 76” with the same footnote about F, in tables that do not say which models show each code. The same tables list 760, a remote controller transmission abnormality, with a check of the wiring if a multi-system or Quick-Connect is in use, and 410, a multi-system flow imbalance error (Field Manual KS-11-0004, p. 26; Field Manual June 2011, p. 34).

Related codes: 76, 78, 760, 768. All Noritz codes

Noritz 90 (combustion abnormality): what to check

Checked

Noritz display

90

“(1) [When supplying combustion air from the indoors] The air supply vent may be clogged. (2) Exhaust vent may be clogged. (3) Abnormal combustion, low gas supply pressure. (4) Condensate drain line may be clogged.”

Owner checks, then technician

EZ, NRCR · EZ/NRCR guide 10/25 p. 31; EZ/NRCR guide 01/24 p. 25; EZ guide SBB8163-2 p. 18; EZ guide SBB80T9-2 p. 28; NRCR guide 04/21 p. 20

Quoted from the EZ/NRCR Owner's Guide Rev. 10/25, which prints 90, 901 and 902 in this row (p. 31); the 2024 guide prints 90, 901 and 908 (EZ/NRCR Owner's Guide Rev. 01/24, p. 25). Other guides list fewer causes. NRC98, 2017 NRC111, NERC, NRC83 and NRC1111: causes (1) and (3) (NRC98 Owner's Guide Rev. 01/17, p. 28; NRC83/NRC98 Owner's Guide Rev. 03/13, p. 27). NR98 (2020) and NR981: “[NR981-SV] The air inlet filter may be clogged.” and cause (3) (NR98 Owner's Guide Rev. 11/20, p. 26; NR981 Owner's Guide Rev. 03/13, p. 27). NR83, NR71DVC, NR50/NR66/NR71, NR111, 2009 NR98 and 2009 NRC111: only “Abnormal combustion, low gas supply pressure” (NR83 Owner's Guide Rev. 11/20, p. 25; NR50/NR66/NR71 Owner's Guide Rev. 01/11, p. 26; NRC111 Owner's Guide Rev. 09/09, p. 27). On EZTR40, NRC661A/NRC711, NRC661, NR501/NR662 and NER66OD heaters the display shows 901, 902, 903 or 908 and the optional remote shows 90 (EZTR40 Owner's Guide Rev. 01/17, p. 24). EZ technical sheets: “Combustion abnormality (Unit shuts off)”.

Short answer On Noritz EZ and NRCR heaters, 90 points to a clogged air supply or exhaust vent, low gas pressure or a clogged condensate line; other models list fewer causes. Check the vents and drain line with the heater off; gas pressure needs a professional. See what to check

What it means

Noritz calls 90 a combustion abnormality (EZ Installation Manual Rev. 10/25, p. 61), and its technical sheet adds that the unit shuts off (EZ Technical Sheet FPFK081, p. 1). The EZ/NRCR Owner’s Guide Rev. 10/25 lists four possible causes: a clogged air supply vent when combustion air comes from indoors, a clogged exhaust vent, low gas supply pressure, and a clogged condensate drain line (p. 31). The NRC and NR guides list fewer causes; see the notes at the end.

Check these first

Before any maintenance, turn the heater off at the operation panel, app or remote controller and let it cool (EZ/NRCR Owner’s Guide Rev. 10/25, p. 3).

  1. If the heater takes combustion air from the room, check the air supply vent for dust, oil or other build-up and remove it with a vacuum cleaner or a damp towel. Do not completely remove the inlet screen and the air screen (EZ/NRCR Owner’s Guide Rev. 10/25, p. 26).
  2. Check the exhaust vent and its terminal for blockage, dust or soot (EZ/NRCR Owner’s Guide Rev. 10/25, pp. 26, 31). Noritz says not to use the heater if the intake or exhaust pipe is displaced, has holes, is clogged or is corroded (EZ/NRCR Owner’s Guide Rev. 10/25, p. 2).
  3. On EZ and NRCR heaters, check whether the condensate drain line is clogged or frozen (EZ/NRCR Owner’s Guide Rev. 10/25, p. 31).
  4. On NRC98, 2017 NRC111, NERC, NRC83 and NRC1111 heaters, the 90 row asks you to clean the air supply vent (NRC98 Owner’s Guide Rev. 01/17, p. 28). The NRC98 guide’s instructions match step 1 and say not to permanently remove the inlet screen (NRC98 Owner’s Guide Rev. 01/17, p. 21).
  5. If the display continues, contact the nearest Noritz agent (EZ/NRCR Owner’s Guide Rev. 10/25, p. 31) or Noritz America Technical Support at 1-866-766-7489 (EZ/NRCR Owner’s Guide Rev. 10/25, p. 32).

The owner’s guides give no reset step for 90.

When to call a licensed technician

  • Gas supply pressure. Every guide that lists low gas pressure for 90 says to have a professional check it (EZ/NRCR Owner’s Guide Rev. 10/25, p. 31; NR83 Owner’s Guide Rev. 11/20, p. 25). The pressure ranges are on the code 11 page.
  • No water comes out of the end of the condensate drain line. A qualified service technician must clean the line (EZ/NRCR Owner’s Guide Rev. 10/25, p. 25).
  • A damaged vent, or one that has to be taken apart. The venting system must be examined periodically for leaks or corrosion by a qualified service technician (EZ Installation Manual Rev. 10/25, p. 69).
  • 908 on an EZ or NRCR heater covered by the 01/24 guide. The technical sheet says it means an internal lock has been activated (EZ Technical Sheet FHCK080, p. 1).
  • The heater still shows 90 after these checks. Noritz’s sheet for service technicians adds checks that the condensate drain pipe slopes down and that the unit settings on the circuit board are right, and gives its reset as disconnecting and reconnecting power (EZ Technical Sheet FPFK081, p. 1).

Notes for different models

  • EZ and NRCR: the 2025 guide prints 90, 901 and 902 in one row, the 2024 guide 90, 901 and 908 (EZ/NRCR Owner’s Guide Rev. 10/25, p. 31; EZ/NRCR Owner’s Guide Rev. 01/24, p. 25). The 2021 guides list 90 alone (EZ Owner’s Guide SBB8163-2, p. 18; NRCR Owner’s Guide Rev. 04/21, p. 20).
  • NRC98, 2017 NRC111, NERC, NRC83 and NRC1111: two causes, the air supply vent and low gas supply pressure (NRC98 Owner’s Guide Rev. 01/17, p. 28).
  • NR98 (2020) and NR981: the first cause is labeled “[NR981-SV] The air inlet filter may be clogged.” The NR98 guide’s action for it is to clean the air supply vent, the NR981 guide’s is to clean the air inlet filter (NR98 Owner’s Guide Rev. 11/20, p. 26; NR981 Owner’s Guide Rev. 03/13, p. 27). The NR98SV has an air inlet filter that must not be removed; if it is removed or damaged, contact Noritz America (NR98 Owner’s Guide Rev. 11/20, p. 21).
  • NR83, NR71DVC, NR50/NR66/NR71, NR111, the 2009 NR98 and the 2009 NRC111: low gas supply pressure is the only cause, with a professional check and a call to the nearest Noritz agent. These guides give no owner check for 90 (NR83 Owner’s Guide Rev. 11/20, p. 25; NR50/NR66/NR71 Owner’s Guide Rev. 01/11, p. 26).
  • EZTR40, NRC661A/NRC711, NRC661, NR501/NR662 and NER66OD: the display shows 901, 902, 903 or 908, and the optional remote shows 90 (EZTR40 Owner’s Guide Rev. 01/17, p. 24). See the 903 page.

Related codes: 903, 902, 99, 29. All Noritz codes

Noritz 903 (abnormal combustion): what to check

Checked

Noritz display

903

“Abnormal combustion. The air inlet filter may be clogged.”

Owner checks, then technician

EZTR40 · EZTR40 Owner's Guide Rev. 01/17, p. 24; EZTR40 Technical Sheet EXSK072, p. 1

Quoted from the EZTR40 guide (EZTR40 Owner's Guide Rev. 01/17, p. 24); its technical sheet calls it “Combustion abnormality (Unit shuts off)” (EZTR40 Technical Sheet EXSK072, p. 1). The optional remote shows 90. Other models give 903 a different cause. NRC661A/NRC711 and NRC661: “Abnormal combustion. [When supplying combustion air from the indoors] The air supply vent may be clogged.” (NRC661A/NRC711 Owner's Guide Rev. 01/17, p. 25; NRC661 Owner's Guide Rev. 01/13, p. 25). NR501/NR662 and NER66OD: “Abnormal combustion.” (NR501/NR662 Owner's Guide Rev. 01/17, p. 24; NER66OD Owner's Guide Rev. 11/19, p. 24).

Short answer On the Noritz EZTR40, code 903 means abnormal combustion: the air inlet filter may be clogged (other models word it differently). With the heater off and cool, vacuum a clogged filter without removing it; if 903 continues, contact a Noritz agent. See what to check

What it means

903 is an abnormal combustion code on Noritz heaters that show three-digit codes: the EZTR40, NRC661A/NRC711, NRC661, NR501/NR662 and NER66OD. Their guides put 901 and 903 in one row, with 908 too except in the NRC661 guide, and give 902 its own row for low gas supply pressure; the optional remote controller shows all of them as 90 (EZTR40 Owner’s Guide Rev. 01/17, p. 24; NRC661 Owner’s Guide Rev. 01/13, p. 25). Noritz’s technical sheet says 903 shuts the unit off (EZTR40 Technical Sheet EXSK072, p. 1).

The cause named in the row depends on the model. The EZTR40 guide says the air inlet filter may be clogged (EZTR40 Owner’s Guide Rev. 01/17, p. 24). The NRC661A/NRC711 and NRC661 guides say the air supply vent may be clogged when combustion air comes from indoors (NRC661A/NRC711 Owner’s Guide Rev. 01/17, p. 25; NRC661 Owner’s Guide Rev. 01/13, p. 25). The NR501/NR662 and NER66OD guides say only “Abnormal combustion.” (NR501/NR662 Owner’s Guide Rev. 01/17, p. 24; NER66OD Owner’s Guide Rev. 11/19, p. 24).

Check these first

  1. EZTR40: turn the heater off with the power button or at the power supply and let it cool, then check the air inlet filter for dust, trash or similar build-up and, if it is clogged, clean it with a vacuum cleaner (EZTR40 Owner’s Guide Rev. 01/17, p. 21). Do not remove the filter. If it has been removed or damaged, contact Noritz America; damage from running the heater without it is not covered by the warranty (EZTR40 Owner’s Guide Rev. 01/17, p. 21).
  2. NRC661A/NRC711 and NRC661 that take combustion air from indoors: clean the air supply vent. The code table points to the cleaning instructions on p. 22 of each guide (NRC661A/NRC711 Owner’s Guide Rev. 01/17, p. 25; NRC661 Owner’s Guide Rev. 01/13, p. 25).
  3. NR501/NR662 and NER66OD: the guides give no owner check for 903 (NR501/NR662 Owner’s Guide Rev. 01/17, p. 24; NER66OD Owner’s Guide Rev. 11/19, p. 24).
  4. If the display continues, contact the nearest Noritz agent (EZTR40 Owner’s Guide Rev. 01/17, p. 24). The EZTR40 guide also says to contact Noritz America if a code is indicated again after these actions; its code table gives 866-766-7489 (EZTR40 Owner’s Guide Rev. 01/17, p. 24). The NER66OD code table gives 855-960-3434 (NER66OD Owner’s Guide Rev. 11/19, p. 24).

The owner’s guides give no reset step for 903.

When to call a licensed technician

  • 903 comes back after the filter or vent is clean.
  • 902 appears. Its row says to have a professional check the gas supply pressure and to contact the nearest Noritz agent (EZTR40 Owner’s Guide Rev. 01/17, p. 24). The EZTR40 installation manual gives 4–10.5 in. WC for natural gas and 8–14 in. WC for propane, and says the inlet pressure must be at least 5 in. WC (natural gas) or 8 in. WC (propane) for all appliances in the gas system (EZTR40 Installation Manual Rev. 11/20, p. 16).
  • 908 appears. The technical sheets call it a combustion abnormality with the unit locked, reset by contacting the nearest Noritz agent (EZTR40 Technical Sheet EXSK072, p. 1; NRC661A/NRC711 Technical Sheet EVPK072, p. 1).
  • Anything past the filter or vent. For 903 the sheet for service technicians lists checks for abnormal combustion and for blockage of the flue and air inlet, and gives its reset as disconnecting and reconnecting power (EZTR40 Technical Sheet EXSK072, p. 1).

Notes for different models

  • On the technical sheets, 901 is a warning first and then a shutdown, while 903 and 902 shut the unit off (EZTR40 Technical Sheet EXSK072, p. 1).
  • The NRC661 guide lists 901 and 903 only; its technical sheet also lists 908 (NRC661 Owner’s Guide Rev. 01/13, p. 25; NRC661 Technical Sheet EVRK072, p. 1).
  • The EZ and NRCR documents do not list 903. Their guides print 901, 902 or 908 in the 90 row (EZ/NRCR Owner’s Guide Rev. 10/25, p. 31). See the 90 page.

Related codes: 90, 902, 908. All Noritz codes

How to read a Noritz code

A fault code blinks on the heater’s operation panel or display window and on the remote controller, if there is one (EZ/NRCR Owner’s Guide Rev. 10/25, p. 31; EZTR40 Owner’s Guide Rev. 01/17, p. 24). NRCP heaters flash “Er” before the number (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 39). The EZTR40, NRC661A/NRC711, NRC661, NR501/NR662 and NER66OD show some codes as three digits, such as 903, while their optional remote shows two (EZTR40 Owner’s Guide Rev. 01/17, p. 24; NR501/NR662 Owner’s Guide Rev. 01/17, p. 24). In a Quick Connect multi-system with a remote, an F before the number (except F76) marks a code from the secondary unit (EZ Technical Sheet FPFK081, p. 1).

One number can mean different things on different models, so read the row for your series. The model is on the rating plate and, on 2025 EZ and NRCR heaters, under “Heater Info.” (EZ/NRCR Owner’s Guide Rev. 10/25, p. 32). EZ and NRCR guides come in 2021, 2024 and 2025 editions with different code lists, and none of the Noritz documents we use ties an edition to a serial number.

In the table, EZ also covers the EZTR50 and EZTR75: their product pages link the EZ documents, and the 2025 guide names them only in its warranty table (EZ/NRCR Owner’s Guide Rev. 10/25, p. 36). NRC (2013) is the NRC83, NRC98 and NRC1111 models with -DV or -OD in the name. NR (2009–2013) is the NR50, NR66, NR71, NR111, NR981 and the 2009 NR98-SV and NR98-OD.

Clearing a code

The owner’s guides give reset steps for only a few codes, and the code pages here list them. On NRCP heaters a soft lockout clears by itself once the condition goes away, and a hard lockout (Er.11, Er.29, Er.40, plus Er.72 on the NRCP1112 and NRCP982) clears when you press the Power button off and then on (NRCP1112/NRCP982 Owner’s Guide Rev. 05/19, p. 39; NRCP111/NRCP98 Owner’s Guide Rev. 05/19, p. 34).

If a code comes back after the listed actions, the EZTR40 guide says to contact Noritz America (EZTR40 Owner’s Guide Rev. 01/17, p. 24). Noritz America Technical Support is at 1-866-766-7489 (EZ/NRCR Owner’s Guide Rev. 10/25, p. 32). The NERC98DV and NERC11DV guides name Thermalux Customer Care at 855-960-3434 instead (NERC98DV Owner’s Guide Rev. 11/19, p. 28; NERC11DV Owner’s Guide Rev. 11/19, p. 28).

When to stop and call a professional

  • If the intake or exhaust pipe is displaced, has holes, is clogged or is corroded, do not use the heater (EZ/NRCR Owner’s Guide Rev. 10/25, p. 2).
  • When a gas leak is noticed, the 2025 guide says to stop use, close the gas valve and, for indoor installations, open windows and doors (EZ/NRCR Owner’s Guide Rev. 10/25, p. 3).
  • Gas supply pressure is for a professional to check (EZ/NRCR Owner’s Guide Rev. 10/25, p. 31). Installation, service and any gas conversion are for a qualified installer, service agency or the gas supplier (EZ/NRCR Owner’s Guide Rev. 10/25, p. 4).
  • Flushing the heat exchanger, which the scale codes C1#, C*# and CF# call for, is written for a qualified service professional or authorized Noritz service representative (EZ Installation Manual Rev. 10/25, p. 69; EZTR40 Installation Manual Rev. 11/20, p. 22).

Rows noted “Listed only in Noritz technical documents for service technicians” come from Noritz technical sheets and field manuals. Owner steps on these pages come only from owner’s guides. The two Field Manuals print one error table for many models and do not say which models show each code, so their codes carry the series “Field Manual (models not listed)” (Field Manual KS-11-0004, p. 26; Field Manual June 2011, p. 34). From the NRCR technical sheet, only its NRCR rows 06, 42, 63 and 79 are used here.

See also

Other tankless water heaters: Navien, Rheem, Rinnai

Noritz is a trademark of its owner. How House Works is not affiliated with or endorsed by Noritz.

Sources

40 documents
  1. NORITZ America Corporation. EZ/NRCR Owner's Guide Rev. 10/25. SBB81M1, Rev. 10/25; cover title: Condensing Tankless Gas Water Heater Owner's Guide; covers EZ111DV, NRCR111DV, EZ98DV, NRCR92DV and EZ71DV (GQ-...-FF-1 US models); EZTR50 and EZTR75 are named only in the warranty table (p. 36); p. 1 is the unnumbered cover. Accessed Oct 12, 2026.
  2. NORITZ America Corporation. EZ/NRCR Owner's Guide Rev. 01/24. SBB81HC, Rev. 01/24; cover title: Condensing Tankless Gas Water Heater Owner's Guide; covers the 2024 EZ111DV, NRCR111DV, EZ98DV, NRCR92DV and EZ71DV (GQ-...-FF US models). Accessed Oct 12, 2026.
  3. NORITZ America Corporation. EZ Owner's Guide SBB8163-2. SBB8163-2, Rev. 04/21; covers EZ111DV (GQ-C3260WX-FF US) and EZ98DV (GQ-C2860WX-FF US). Accessed Oct 12, 2026.
  4. NORITZ America Corporation. EZ Owner's Guide SBB80T9-2. SBB80T9-2, Rev. 04/21; covers EZ111DV (GQ-C3259WX-FF US) and EZ98DV (GQ-C2859WX-FF US). Accessed Oct 12, 2026.
  5. NORITZ America Corporation. NRCR Owner's Guide Rev. 04/21. SBB8167-3, Rev. 04/21; covers NRCR111DV (GQ-C3260WXQ-FF US) and NRCR92DV (GQ-C2660WXQ-FF US). Accessed Oct 12, 2026.
  6. NORITZ America Corporation. EZTR40 Owner's Guide Rev. 01/17. SBB809K-2, Rev. 01/17; covers NRC663-FSV (EZTR40). Accessed Oct 12, 2026.
  7. NORITZ America Corporation. NRC661A/NRC711 Owner's Guide Rev. 01/17. SBB8067-4, Rev. 01/17; covers NRC711-DV, NRC711-OD, NRC661A-DV and NRC661A-OD. Accessed Oct 12, 2026.
  8. NORITZ America Corporation. NRC661 Owner's Guide Rev. 01/13. SBB801H, Rev. 01/13; covers NRC661-DV and NRC661-OD. Accessed Oct 12, 2026.
  9. NORITZ America Corporation. NRC98 Owner's Guide Rev. 01/17. SBB80JP-3, Rev. 01/17; covers NRC98DV (GQ-C2857WS-FF US) and NRC98OD (GQ-C2857WS US). Accessed Oct 12, 2026.
  10. NORITZ America Corporation. NRC111 Owner's Guide Rev. 01/17. SBB80HS-3, Rev. 01/17; covers NRC111DV (GQ-C3257WX-FF US) and NRC111OD (GQ-C3257WX US). Accessed Oct 12, 2026.
  11. NORITZ America Corporation. NERC98DV Owner's Guide Rev. 11/19. SBB818C-1, Rev. 11/19; covers NERC98DV (GQ-C2857WS-FF ET US); contact lines name Thermalux Customer Care, 855-960-3434. Accessed Oct 12, 2026.
  12. NORITZ America Corporation. NERC11DV Owner's Guide Rev. 11/19. SBB818A-1, Rev. 11/19; covers NERC11DV (GQ-C3257WX-FF ET US); contact lines name Thermalux Customer Care, 855-960-3434. Accessed Oct 12, 2026.
  13. NORITZ America Corporation. NRC83/NRC98 Owner's Guide Rev. 03/13. SBA8884-1, Rev. 03/13; covers NRC98-DV, NRC98-OD, NRC83-DV and NRC83-OD. Accessed Oct 12, 2026.
  14. NORITZ America Corporation. NRC111 Owner's Guide Rev. 09/09. SBA8370, Rev. 09/09; covers NRC111-SV and NRC111-DV. Accessed Oct 12, 2026.
  15. NORITZ America Corporation. NRC1111 Owner's Guide Rev. 03/13. SBA8723-1, Rev. 03/13; covers NRC1111-DV and NRC1111-OD. Accessed Oct 12, 2026.
  16. NORITZ America Corporation. NRCP1112/NRCP982 Owner's Guide Rev. 05/19. Rev. 05/19, no SB number printed; title line: NRCP1112-DV / NRCP982-DV (Eco TOUGH). Accessed Oct 12, 2026.
  17. NORITZ America Corporation. NRCP111/NRCP98 Owner's Guide Rev. 05/19. Rev. 05/19, no SB number printed; covers NRCP111-DV and NRCP98-DV (listed by Noritz as the 2019 models). Accessed Oct 12, 2026.
  18. NORITZ America Corporation. NR98 Owner's Guide Rev. 11/20. SBB80J3-4, Rev. 11/20; covers NR98OD (GQ-2857WX US), NR98DVC (GQ-2857WX-FFA US) and NR98SV (GQ-2857WX-F US). Accessed Oct 12, 2026.
  19. NORITZ America Corporation. NR83 Owner's Guide Rev. 11/20. SBB80YQ-2, Rev. 11/20; covers NR83DVC (GQ-2457WS-FFA US) and NR83OD (GQ-2457WS US). Accessed Oct 12, 2026.
  20. NORITZ America Corporation. NR71DVC Owner's Guide Rev. 04/25. SBB81MS, Rev. 04/25; covers NR71DVC (GQ-2457WS-FFA-1 US). Accessed Oct 12, 2026.
  21. NORITZ America Corporation. NR50/NR66/NR71 Owner's Guide Rev. 01/11. SBA8654, Rev. 01/11; covers NR71-SV, NR71-OD, NR66-SV, NR66-OD and NR50-OD. Accessed Oct 12, 2026.
  22. NORITZ America Corporation. NR501/NR662 Owner's Guide Rev. 01/17. SBB8065-5, Rev. 01/17; covers NR662-OD and NR501-OD. Accessed Oct 12, 2026.
  23. NORITZ America Corporation. NR111 Owner's Guide Rev. 09/09. SBA8373, Rev. 09/09; covers NR111-SV, NR111-OD and NR111-DV. Accessed Oct 12, 2026.
  24. NORITZ America Corporation. NR981 Owner's Guide Rev. 03/13. SBA8893-1, Rev. 03/13; covers NR981-OD, NR981-DVC and NR981-SV. Accessed Oct 12, 2026.
  25. NORITZ America Corporation. NR98 Owner's Guide Rev. 09/09. SBA8346, Rev. 09/09; covers NR98-SV and NR98-OD; Noritz also lists SBA8349 (NR98-DVC) and SBA8352 (NR98-DVC-CA), which were not compared. Accessed Oct 12, 2026.
  26. NORITZ America Corporation. NER66OD Owner's Guide Rev. 11/19. SBB818E-1, Rev. 11/19; covers NER66OD (GQ-2039WS ET US); contact lines name Thermalux Customer Care, 855-960-3434. Accessed Oct 12, 2026.
  27. NORITZ America Corporation. EZ Technical Sheet FPFK081. Sheet code FPFK081, no revision or date printed; 2025 EZ111DV, EZ98DV and EZ71DV (GQ-...-FF-1 US); a service document filed under Field Manual in Noritz's Technical Literature; no page numbers printed, p. 1 is the PDF page. Accessed Oct 12, 2026.
  28. NORITZ America Corporation. EZ Technical Sheet FHCK080. Sheet code FHCK080, no revision or date printed; 2024 EZ111DV, EZ98DV and EZ71DV (GQ-...-FF US); a service document; no page numbers printed, p. 1 is the PDF page. Accessed Oct 12, 2026.
  29. NORITZ America Corporation. EZ Technical Sheet FABK080. Sheet code FABK080, no revision or date printed; 2021 EZ111DV (GQ-C3259WX-FF US) and EZ98DV (GQ-C2859WX-FF US); a service document; no page numbers printed, p. 1 is the PDF page. Accessed Oct 12, 2026.
  30. NORITZ America Corporation. EZ Technical Sheet FDAK080. Sheet code FDAK080, no revision or date printed; 2021 EZ111DV (GQ-C3260WX-FF US) and EZ98DV (GQ-C2860WX-FF US); a service document; no page numbers printed, p. 1 is the PDF page. Accessed Oct 12, 2026.
  31. NORITZ America Corporation. NRCR Technical Sheet FPHK081. Sheet code FPHK081, no revision or date printed; 2025 NRCR111DV and NRCR92DV (GQ-...-FF-1 US); image-only PDF; only its NRCR rows 06, 42, 63 and 79 are used on this site; a service document; no page numbers printed, p. 1 is the PDF page. Accessed Oct 12, 2026.
  32. NORITZ America Corporation. EZTR40 Technical Sheet EXSK072. Sheet code EXSK072, no revision or date printed; a service document filed under Field Manual in Noritz's Technical Literature; no page numbers printed, p. 1 is the PDF page. Accessed Oct 12, 2026.
  33. NORITZ America Corporation. NRC661A/NRC711 Technical Sheet EVPK072. Sheet code EVPK072, no revision or date printed; a service document; no page numbers printed, p. 1 is the PDF page. Accessed Oct 12, 2026.
  34. NORITZ America Corporation. NRC661 Technical Sheet EVRK072. Sheet code EVRK072, no revision or date printed; a service document; no page numbers printed, p. 1 is the PDF page. Accessed Oct 12, 2026.
  35. NORITZ America Corporation. NRCP1112/NRCP982 Technical Data Sheet Rev. 03/17. Rev. 03/17 (printed at the foot of p. 1); a service document filed under Field Manual; no page numbers printed, p. 2 is the PDF page. Accessed Oct 12, 2026.
  36. NORITZ America Corporation. NRCP111/NRCP98 Technical Data Sheet Rev. 07/19. Rev. 07/19 (printed at the foot of p. 1); a service document filed under Field Manual; no page numbers printed, p. 2 is the PDF page. Accessed Oct 12, 2026.
  37. NORITZ America Corporation. Field Manual KS-11-0004. KS-11-0004, Rev. October 2012; cover title: Gas Water Heater Field Manual (NRC83, NRC98, NRC1111/NCC1991, NR981/NC199, NR83-DVC); written for service technician training seminars. Accessed Oct 12, 2026.
  38. NORITZ America Corporation. Field Manual June 2011. Rev. June 2011; cover title: Gas Water Heater Field Manual (NR50-OD, NR66, NR71, NR98, NCC199, NRC111, NR111, NC380); a service technician training document. Accessed Oct 12, 2026.
  39. NORITZ America Corporation. EZ Installation Manual Rev. 10/25. SBB81M3-1, Rev. 10/25; cover title: Condensing Tankless Gas Water Heater Installation Manual; covers EZ111DV, EZ98DV and EZ71DV (GQ-...-FF-1 US); linked from the EZTR50 and EZTR75 product pages, which the manual does not name. Accessed Oct 12, 2026.
  40. NORITZ America Corporation. EZTR40 Installation Manual Rev. 11/20. SBB809L-2, Rev. 11/20; covers NRC663-FSV (EZTR40), indoor installation; p. 22 is an image page without a text layer. Accessed Oct 12, 2026.