Rinnai tankless water heater error codes
38 codes for RU/RUR/RSC, RX, RE/REP, V, RL/VC, each with the wording and page from Rinnai's manuals.
How House Works EditorialChecked against 15 sources,
- Prepared by
- How House Works Editorial
- How it is checked
- Methodology
- Page
- HHW · ERROR-CODES · RINNAI
- Based on
- Rinnai manuals
Meanings are quoted from Rinnai's manuals. The "Who" column is our reading of the manual's remedy: whether an owner can do the first checks, or the fix belongs to a licensed technician.
Codes with step-by-step checks
- 10Air supply or exhaust blockage
- 11No ignition
- 12No flame
- 14Overheat or thermal fuse
- 16High outgoing temperature
- 25Condensate pump
- 61Combustion fan
- 63Recirculation low flow
- 79Water leak detected
- LCScale build-up
How it works: How a tankless water heater lights: ignition codes by brand
All Rinnai codes
| Code | Manual meaning | Who | Series | Source |
|---|---|---|---|---|
| 02 | “No burner operation during freeze protection mode” Among Rinnai's owner tables, only the V53De manual lists code 02, with the remedy "Service Call" (p. 28). The troubleshooting guide applies it to Non-SENSEI models (pp. 6–8). | Technician | V | V53De manual p. 28; Troubleshooting guide p. 6–8 |
| 03 | “Power interruption during bath fill (Water will not flow when power returns)” | Owner can check | RU/RUR/RSC, RX, V, RL/VC | 7 documentsRU manual p. 73; RUR manual p. 72; RSC manual p. 72; RX/CX tech sheet p. 1; Value manual p. 34; VC manual p. 37; Troubleshooting guide p. 9 |
| 05 | “By-Pass Flow Control” The troubleshooting guide also applies code 05 to Non-SENSEI models (p. 10), but the RE, REP, Value, V53De and VC tables do not list it. | Technician | RU/RUR/RSC | RU manual p. 73; RUR manual p. 72; RSC manual p. 72; Troubleshooting guide p. 10 |
| 10 | “Air Supply or Exhaust Blockage/ Condensate Trap is Full” What to check RE/REP, Value, V53De and VC tables: "Air Supply or Exhaust Blockage" (RE manual, p. 49). The condensate trap applies to SENSEI and SENSEI RX/CX models only (troubleshooting guide, p. 12). | Owner checks, then technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 73; RUR manual p. 72; RSC manual p. 72; RX/CX tech sheet p. 1; RE manual p. 49; REP manual p. 48; Value manual p. 34; V53De manual p. 28; VC manual p. 37; Troubleshooting guide p. 12–15 |
| 11 | “No Ignition (Heater Not Turning On)” What to check | Owner checks, then technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 73; RUR manual p. 72; RSC manual p. 72; RX/CX tech sheet p. 1; RE manual p. 49; REP manual p. 48; Value manual p. 34; V53De manual p. 28; VC manual p. 37; Troubleshooting guide p. 16–19 |
| 12 | “No Flame” What to check | Owner checks, then technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 73; RUR manual p. 72; RSC manual p. 72; RX/CX tech sheet p. 1; RE manual p. 50; REP manual p. 49; Value manual p. 34; V53De manual p. 28; VC manual p. 37; Troubleshooting guide p. 20–21 |
| 14 | “Heat Exchanger Overheat” What to check RE/REP tables: "Thermal Fuse" (RE manual, p. 50). Value, V53De and VC tables: "Thermal Fuse has activated" (Value manual, p. 34). | Owner checks, then technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 73; RUR manual p. 72; RSC manual p. 72; RX/CX tech sheet p. 1; RE manual p. 50; REP manual p. 49; Value manual p. 34; V53De manual p. 29; VC manual p. 37; Troubleshooting guide p. 23–25 |
| 15 | “Venturi Control” | Technician | RU/RUR/RSC, RX | 5 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; Troubleshooting guide p. 26 |
| 16 | “High Outgoing Temperature (safety shutdown because water heater is too hot)” What to check RE/REP tables: "High Outgoing Temperature" (RE manual, p. 50). Value, V53De and VC tables: "Over Temperature Warning (safety shutdown because unit is too hot)" (Value manual, p. 34). The troubleshooting guide defines it as outlet water above 203°F (95°C) (p. 27). | Owner checks, then technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; RE manual p. 50; REP manual p. 49; Value manual p. 34; V53De manual p. 29; VC manual p. 37; Troubleshooting guide p. 27 |
| 17 | “Venturi Blockage” The RX/CX tech sheet reads "Please call Rinnai technical department to reset the code." (p. 1). The board-button reset in the troubleshooting guide (pp. 28–29) is a technician procedure. | Technician | RU/RUR/RSC, RX | 5 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; Troubleshooting guide p. 28–29 |
| 18 | “Gas Valve Adjustment Limit” | Technician | RX | RX/CX tech sheet p. 1; Troubleshooting guide p. 30 |
| 19 | “Electrical Grounding” | Technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; RE manual p. 50; REP manual p. 49; Value manual p. 35; V53De manual p. 29; VC manual p. 38; Troubleshooting guide p. 31 |
| 21 | “Data Transfer Error” | Technician | RU/RUR/RSC, RX | 5 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; Troubleshooting guide p. 32 |
| 22 | “Gas Valve Adjustment Error” | Technician | RX | RX/CX tech sheet p. 1; Troubleshooting guide p. 33 |
| 25 | “Condensate Pump (Accessory)” What to check | Owner checks, then technician | RU/RUR/RSC, RX | 5 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; Troubleshooting guide p. 34 |
| 31 | “Burner Thermocouple” Listed only in Rinnai's technician troubleshooting guide. The guide applies it to RH180 and to its "Non-SENSEI Series" group (p. 36), which also covers models outside this table (p. 2). The RE, REP, Value, V53De and VC tables do not list code 31. | Technician | Non-SENSEI | Troubleshooting guide p. 36 |
| 32 | “Outgoing Thermistor” RE and REP tables: "Outgoing Water Temperature Thermistor" (RE manual, p. 50). Value, V53De and VC tables: "Outgoing Water Temperature Sensor" (Value manual, p. 35). | Technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; RE manual p. 50; REP manual p. 49; Value manual p. 35; V53De manual p. 29; VC manual p. 38; Troubleshooting guide p. 37 |
| 33 | “Heat Exchanger Thermistor” Value, V53De and VC tables: "Heat Exchanger Outgoing Temperature Sensor" (Value manual, p. 35). | Technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; RE manual p. 50; REP manual p. 49; Value manual p. 35; V53De manual p. 29; VC manual p. 38; Troubleshooting guide p. 38 |
| 34 | “Lime Detecting Thermistor” On RE/REP, Value and VC models code 34 is a combustion air sensor: "Combustion Air Temperature Thermistor Fault" (RE manual, p. 51), "Combustion Air Temperature Sensor Fault" (Value manual, p. 35), "Combustion Air Temperature Sensor" (VC manual, p. 38). | Technician | RX, RE/REP, V, RL/VC | 6 documentsRX/CX tech sheet p. 1; RE manual p. 51; REP manual p. 50; Value manual p. 35; VC manual p. 38; Troubleshooting guide p. 39–40 |
| 38 | “Exhaust Thermistor” | Technician | RU/RUR/RSC, RX | 5 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; Troubleshooting guide p. 42–43 |
| 41 | “Freeze Protection Thermistor” Value and V53De tables: "Outside temperature thermistor" (Value manual, p. 35). VC table: "Outside temperature thermistor (outdoor models only)" (VC manual, p. 38). | Technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; RE manual p. 51; REP manual p. 50; Value manual p. 35; V53De manual p. 29; VC manual p. 38; Troubleshooting guide p. 44 |
| 51 | “Inlet Thermistor” RE and REP tables: "Inlet Water Temperature Thermistor" (RE manual, p. 51). Value and VC tables: "Inlet water temperature thermistor" (Value manual, p. 35). | Technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 9 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; RE manual p. 51; REP manual p. 50; Value manual p. 35; VC manual p. 38; Troubleshooting guide p. 45 |
| 52 | “Gas Valve” RE/REP, Value, V53De and VC tables: "Modulating Solenoid Valve Signal" (RE manual, p. 51). | Technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; RE manual p. 51; REP manual p. 50; Value manual p. 35; V53De manual p. 29; VC manual p. 38; Troubleshooting guide p. 46–48 |
| 54 | “High Exhaust Gas Temperature” | Owner checks, then technician | RU/RUR/RSC, RX | 5 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; Troubleshooting guide p. 49 |
| 57 | “Burner Overheat Bi-Metal Switch” Listed only in Rinnai's technician troubleshooting guide. The guide applies it to its "Non-SENSEI Series" group (p. 50), which also covers models outside this table (p. 2), and refers KB models to Technical Bulletin 107 (p. 50). The RE, REP, Value, V53De and VC tables do not list code 57. | Technician | Non-SENSEI | Troubleshooting guide p. 50 |
| 58 | “Secondary Heat Exchanger Sensor” Listed only in Rinnai's technician troubleshooting guide. The guide applies it to its "Non-SENSEI Series" group (p. 51), which also covers models outside this table (p. 2). The RE, REP, Value, V53De and VC tables do not list code 58. | Technician | Non-SENSEI | Troubleshooting guide p. 51 |
| 61 | “Combustion Fan” What to check | Technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; RE manual p. 51; REP manual p. 50; Value manual p. 35; V53De manual p. 29; VC manual p. 38; Troubleshooting guide p. 52 |
| 63 | “Recirculation Low Flow” What to check | Owner checks, then technician | RU/RUR/RSC, RX, RE/REP | 7 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; RE manual p. 51; REP manual p. 50; Troubleshooting guide p. 53–54 |
| 65 | “Water Flow Control” RE and REP tables: "Water Flow Servo" (RE manual, p. 51). The RU, RX/CX, Value and VC rows say the water flow control valve has failed to close during the bath fill function: turn off the water immediately, stop the bath fill function and contact a professional (RU manual, p. 74; Value manual, p. 35). | Technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 9 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; RE manual p. 51; REP manual p. 50; Value manual p. 35; VC manual p. 38; Troubleshooting guide p. 55 |
| 66 | “Flow Servo” RE and REP tables: "Bypass Flow Servo" (RE manual, p. 51; REP manual, p. 50). The troubleshooting guide applies code 66 to SENSEI RX/CX models only (p. 56). | Technician | RX, RE/REP | RX/CX tech sheet p. 1; RE manual p. 51; REP manual p. 50; Troubleshooting guide p. 56 |
| 70 | “PC Board” | Technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 74; RUR manual p. 73; RSC manual p. 73; RX/CX tech sheet p. 1; RE manual p. 51; REP manual p. 50; Value manual p. 35; V53De manual p. 29; VC manual p. 38; Troubleshooting guide p. 57 |
| 71 | “Solenoid Valve Circuit” | Technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 75; RUR manual p. 74; RSC manual p. 74; RX/CX tech sheet p. 1; RE manual p. 51; REP manual p. 50; Value manual p. 35; V53De manual p. 29; VC manual p. 38; Troubleshooting guide p. 58–59 |
| 72 | “Flame Rod” RE, REP, Value, V53De and VC tables: "Flame Sensing Device" (RE manual, p. 51; Value manual, p. 35). | Technician | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 75; RUR manual p. 74; RSC manual p. 74; RX/CX tech sheet p. 1; RE manual p. 51; REP manual p. 50; Value manual p. 35; V53De manual p. 29; VC manual p. 38; Troubleshooting guide p. 60 |
| 73 | “Burner Thermocouple Fault” Listed only in Rinnai's technician troubleshooting guide. The guide applies it to its "Non-SENSEI Series" group (p. 61), which also covers models outside this table (p. 2). The RE, REP, Value, V53De and VC tables do not list code 73. | Technician | Non-SENSEI | Troubleshooting guide p. 61 |
| 79 | “Water Leak Detected” What to check In the V series only the Value manual lists code 79 (p. 35); the V53De table does not. | Technician | RE/REP, V, RL/VC | 5 documentsRE manual p. 51; REP manual p. 50; Value manual p. 35; VC manual p. 38; Troubleshooting guide p. 62 |
| FF | “Maintenance Indicator” Not a fault and nothing for the owner to fix: a placeholder that a service provider enters in the code history after maintenance or service (RU manual, p. 75). Value and VC tables: "Maintenance has been performed", in the owner-level column (Value manual, p. 35). | Owner can check | 5 seriesRU/RUR/RSC, RX, RE/REP, V, RL/VC | 10 documentsRU manual p. 75; RUR manual p. 74; RSC manual p. 74; RX/CX tech sheet p. 1; RE manual p. 52; REP manual p. 51; Value manual p. 35; V53De manual p. 29; VC manual p. 38; Troubleshooting guide p. 64 |
| LC | “Scale Build-up in Heat Exchanger (when checking maintenance code history, “00” is substituted for “LC”)” What to check Clearing LC after a flush differs by manual: a PC board procedure for a trained and qualified technician (RE manual, p. 52); "reset LC code as instruction" and a call to the Rinnai technical department, with no procedure (REP manual, p. 51); a call to Rinnai technical assistance for PCB reset information (Value manual, p. 38); a board-button reset that the troubleshooting guide says is not in owner manuals (pp. 67–68). | Owner checks, then technician | RX, RE/REP, V, RL/VC | 7 documentsRX/CX tech sheet p. 1; RE manual p. 52; REP manual p. 51; Value manual p. 35; V53De manual p. 29; VC manual p. 38; Troubleshooting guide p. 67–68 |
| SS | “Service Soon (Flush Heat Exchanger)” RX/CX tech sheet: "(SS) Service Soon", without "(Flush Heat Exchanger)" (p. 1). On RX models SS is reset by holding the "A" button until SS disappears (SENSEI RX/CX Tech Sheet, p. 1; RX manual, p. 50); the A and B buttons are on the PC board behind the front panel (RX manual, p. 67). The RU, RUR, RSC, RE and REP tables reset SS with five presses of On/Off within 5 seconds (RU manual, p. 75). | Owner checks, then technician | RU/RUR/RSC, RX, RE/REP | 8 documentsRU manual p. 75; RUR manual p. 74; RSC manual p. 74; RX/CX tech sheet p. 1; RX manual p. 50; RE manual p. 52; REP manual p. 51; Troubleshooting guide p. 66 |
What to check, code by code
Rinnai code 10 (air supply or exhaust blockage): what to check
Checked
Rinnai display
10
“Air Supply or Exhaust Blockage/ Condensate Trap is Full”
Printed on 5 model series · 10 documents
Short answer Rinnai code 10 means an air supply or exhaust blockage; on condensing RU, RUR, RSC and RX models it also covers a full condensate trap. Check that nothing blocks the outdoor vent termination; if you cannot clear it easily, call a qualified professional. See what to check
What it means
Code 10 is Rinnai’s code for a blocked combustion air supply or exhaust. Rinnai says the heater will not function properly if the combustion air or exhaust vent pipes are blocked or partly blocked (RU manual, p. 77).
On the condensing RU, RUR, RSC and RX models, the same code also covers a full condensate trap; the troubleshooting guide limits that part to SENSEI and SENSEI RX/CX models (p. 12). If the condensate drain line clogs or freezes, condensate backs up into the trap inside the heater, and the heater shuts off to prevent spillage and shows code 10 (p. 12).
Check these first
Rinnai’s tables warn that consumers should never attempt any action they are not qualified to perform (RU manual, p. 73; Value manual, p. 34). The V53De manual adds: call a licensed professional for any remedy that involves gas or electricity, or if you have any doubt about doing it yourself (V53De manual, p. 28). If you smell gas, the Value and V53De manuals put one step before those in the box above: leave the premises (Value manual, p. 28; V53De manual, p. 22).
- Outside, check that nothing blocks the vent termination, on the air intake side or the exhaust side (Value manual, p. 34; RU manual, p. 73). Clear snow and ice from around the flue terminal (RU manual, p. 77).
- On Value and VC models, also look over the vent components you can see for proper connections; the table lists this as an owner check (Value manual, p. 34; VC manual, p. 37). Repairs are not: venting materials and vent length are “licensed professional only” items (Value manual, p. 34).
- On RU, RUR, RSC and RX models, check the condensate drain line (RU manual, p. 73; SENSEI RX/CX Tech Sheet, p. 1). Condensate should be flowing, the line should not be blocked or frozen, and its end should be open to the air, not under water (RU manual, pp. 54, 76–77).
- If the vent is blocked and you cannot easily clear it, contact a trained and qualified professional (RU manual, p. 76).
The tables give no separate reset step for code 10.
When to call a licensed technician
- The internal air filter on indoor RU, RUR, RSC and RX units (RU manual, p. 73). It sits behind the front panel (pp. 78–79), and Rinnai says the panel comes off only for service, maintenance or replacing internal parts (p. 8).
- Approved venting materials and vent length (RU manual, p. 73; Value manual, p. 34). On RE and REP models, the vent length must match the vent length set in the parameters (RE manual, p. 49).
- The high altitude setting (RU manual, p. 73). Only trained and qualified professionals may change parameter settings (p. 8).
- The fan: debris, whether the wheel turns freely, and the check valve between the fan casing and the burner body (RU manual, p. 73).
- DIP switches on Value and VC models (Value manual, p. 34; VC manual, p. 37).
- Other causes the troubleshooting guide names: a defective fan motor, its wiring harness or the PC board, and on Non-SENSEI models the manifold gas pressure settings (pp. 13, 15).
Notes for different models
The RE, REP, Value, V53De and VC tables name code 10 without the condensate trap (RE manual, p. 49; Value manual, p. 34). The V53De is an outdoor model (V53De manual, p. 22); its owner check is that nothing blocks the inlet or exhaust (p. 28).
On SENSEI and RX models, the remedy for code 17 (venturi blockage) starts with the code 10 remedies (RU manual, p. 74).
Related codes: 17, 25, 61. All Rinnai codes
Rinnai code 12 (no flame): what to check
Checked
Rinnai display
12
“No Flame”
Printed on 5 model series · 10 documents
Short answer Rinnai code 12 means no flame. Check that the gas is on and a propane tank has gas; on RE, REP, Value, V53De and VC, also check the flue outlet. If the heater still does not run, call a licensed technician. See what to check
What it means
Rinnai’s troubleshooting guide titles code 12 “Flame Failure” (p. 20). The owner checks start the same way as for code 11, with the gas supply and the propane tank (RU manual, p. 73). The RE, REP, Value, V53De and VC tables add a look at the flue outlet (RE manual, p. 50; Value manual, p. 34).
The guide’s list for the technician covers inlet gas pressure and gas pipe sizing, the flame rod and spark electrode, grounding of the electrical circuit, and debris or insects in the fan. It also names venting faults that let combustion gases recirculate, which it says may cause incomplete combustion and code 12 (pp. 20–21). If code 12 shows immediately after water starts to flow, the guide points to an electrical short in one of the heater’s DC components (p. 21).
Check these first
Rinnai’s tables warn that consumers should never attempt any action they are not qualified to perform (RU manual, p. 73; Value manual, p. 34). The V53De manual adds: call a licensed professional for any remedy that involves gas or electricity, or if you have any doubt about doing it yourself (V53De manual, p. 28). If you smell gas, the Value and V53De manuals put one step before those in the box above: leave the premises (Value manual, p. 28; V53De manual, p. 22).
- Check that the gas is turned on at the water heater, the gas meter, or the cylinder (RU manual, p. 73; Value manual, p. 34). Turn the manual gas valve by hand only, never with tools (RU manual, p. 8). If the valve at the heater was closed, reopen it only as the operating instructions describe, including the five-minute wait with the valve off and the check for a gas smell near the floor (RU manual, p. 68; Value manual, p. 29).
- If the heater runs on propane, make sure there is gas in the tank (RU manual, p. 73; Value manual, p. 34).
- Outside, check the flue outlet for obstructions (Value manual, p. 34; RE manual, p. 50). Keep the area around the flue terminal free of snow and ice (RU manual, p. 77). If the vent is blocked and you cannot easily clear it, contact a trained and qualified professional (RU manual, p. 76).
- If the heater still does not run, turn off the gas to the appliance as the operating instructions describe, then call a service technician or the gas supplier (RU manual, p. 68; Value manual, p. 29).
When to call a licensed technician
The Value, V53De and VC tables mark these remedies “licensed professional only” (Value manual, p. 34; V53De manual, p. 28; VC manual, p. 37):
- Gas line, meter and regulator sizing, gas type and pressure, and bleeding air from the gas lines. Inlet pressure ranges differ by series; the Rinnai code 11 page lists them with sources and conditions.
- The condensation collar. The Value and VC tables also list the venting material and vent length (Value manual, p. 34; VC manual, p. 37); the V53De table does not (p. 28).
- DIP switch settings.
- Power supply connections, voltage and voltage drops, wiring harnesses, and DC shorts at components.
- The flame rod wire, carbon build-up on the flame rod, the gas solenoid valves, and condensation or debris on the burner surface.
The troubleshooting guide stresses a properly grounded circuit and, if there is any doubt, sends the circuit to a licensed electrician (p. 21).
Notes for different models
The RU, RUR, RSC and RX tables list five remedies for code 12: gas on, gas in the propane tank, the flame rod wire, gas type and inlet pressure, and bleeding air from the gas lines (RU manual, p. 73; SENSEI RX/CX Tech Sheet, p. 1). The flue outlet check appears only in the RE, REP, Value, V53De and VC tables (RE manual, p. 50; REP manual, p. 49; V53De manual, p. 28; VC manual, p. 37).
Related codes: 11, 72, 19. All Rinnai codes
Rinnai code 14 (overheat or thermal fuse): what to check
Checked
Rinnai display
14
“Heat Exchanger Overheat”
Printed on 5 model series · 10 documents
Short answer Rinnai code 14 is an overheat shutdown: heat exchanger overheat on RU, RUR, RSC and RX; thermal fuse on RE, REP, Value, V53De and VC. On thermal-fuse models, check air flow around the heater and vent terminal. If 14 returns, call a licensed technician. See what to check
What it means
Code 14 is an overheat shutdown. The RU, RUR, RSC and RX tables tie it to the heat exchanger; the RE, REP, Value, V53De and VC tables tie it to a thermal fuse (RU manual, p. 73; RE manual, p. 50; Value manual, p. 34). Rinnai’s troubleshooting guide says the code is a sign of overheating and should be taken seriously (p. 23).
What trips it depends on the series. On SENSEI and RX models, an overheat sensor on the heat exchanger sets the code and resets itself once the heat exchanger cools; if the cause is not corrected, it keeps tripping (troubleshooting guide, p. 23). On Non-SENSEI models two kinds of part can set it: a bi-metal switch that usually resets after cooling, and thermal fuses wrapped around the heat exchanger. The fuses are one-shot parts. A blown fuse must be replaced, which means removing the heat exchanger (p. 24).
Scale is one of the causes the tables name: hot spots on the heat exchanger surface indicate blockage from scale build-up, and the remedy points to the flushing instructions (RU manual, p. 73).
Check these first
Rinnai’s tables warn that consumers should never attempt any action they are not qualified to perform (RU manual, p. 73; Value manual, p. 34). The V53De manual adds: call a licensed professional for any remedy that involves gas or electricity, or if you have any doubt about doing it yourself (V53De manual, p. 28). If you smell gas, the Value and V53De manuals put one step before those in the box above: leave the premises (Value manual, p. 28; V53De manual, p. 22).
- If the heater is overheating or the gas does not shut off, turn off the manual gas control valve to the heater, by hand only (RU manual, p. 8; Value manual, p. 3).
- Check for anything restricting air flow around the heater and the vent terminal (Value manual, p. 34; RE manual, p. 50; VC manual, p. 37). On the outdoor V53De, check around the unit and its exhaust outlet (V53De manual, p. 29).
- Look at the code history to see how often 14 has appeared. Turn the heater off with On/Off, hold On/Off for 2 seconds, then press Up; the last nine codes flash in turn (RU manual, p. 73).
- If 14 keeps coming back, stop and call for service. The troubleshooting guide says the overheat switch will keep tripping until the root cause is corrected (pp. 23–24).
When to call a licensed technician
- Flushing the heat exchanger and treating hard water, which the tables name for scale (RU manual, p. 73). The flush is section 6.3 of the RU manual (p. 80); for RU, RUR and RSC models, Rinnai’s bulletin TB-188 Optimized Flushing Procedure for SENSEI Tankless Water Heaters revises it (p. 1). Rinnai says repairs and maintenance shall be performed by a trained and qualified professional (RU manual, p. 76). The Rinnai LC page summarizes what the flush involves.
- Measuring the overheat switch or the safety circuit (RU manual, p. 73; Value manual, p. 34).
- Gas type, gas conversion, and high and low fire manifold pressure (Value manual, p. 34; RE manual, p. 50).
- Low water flow in a circulating system that causes short-cycling (Value manual, p. 34).
- Foreign material in the combustion chamber or exhaust piping, and cracks or separations in the heat exchanger (Value manual, p. 34).
- DIP switch and parameter settings, including the forced Hi setting on RU, RUR and RSC models (RU manual, p. 73; Value manual, p. 34).
Notes for different models
The air flow check in step 2 comes from the RE, REP, Value, V53De and VC tables. The RU, RUR, RSC and RX tables list only a switch measurement, the scale and flushing items, and the forced Hi setting (RU manual, p. 73; SENSEI RX/CX Tech Sheet, p. 1).
On Value models, the technician also confirms that SW 5 in DIP switch bank 2 is off (Value manual, p. 34). The VC manual describes the same check as switch 5 in the second (white) bank (VC manual, p. 37).
Related codes: 16, 54, LC, SS. All Rinnai codes
Rinnai code 16 (high outgoing temperature): what to check
Checked
Rinnai display
16
“High Outgoing Temperature (safety shutdown because water heater is too hot)”
Printed on 5 model series · 10 documents
Short answer Rinnai code 16 is a safety shutdown because the heater got too hot (an over temperature warning on Value, V53De and VC). Check air flow around the heater and vent terminal on RE, REP, Value, V53De and VC only; call for service if 16 returns. See what to check
What it means
Code 16 is a safety shutdown. Rinnai’s troubleshooting guide defines it as outlet water temperature above 203°F (95°C) (p. 27). The Value, V53De and VC tables call it an over temperature warning (Value manual, p. 34).
The RU, RUR, RSC and RX tables list two remedies, both for parts inside the heater: confirm the fan motor works, and replace the gas valve assembly (RU manual, p. 74; SENSEI RX/CX Tech Sheet, p. 1). These tables do not split remedies between owner and professional; in our reading, neither of the two is an owner task. The Non-SENSEI tables add air flow around the heater and vent terminal, short-cycling from low water flow in a circulating system, foreign material in the combustion chamber or exhaust piping, and blockage in the heat exchanger (Value manual, p. 34; RE manual, p. 50).
Check these first
Rinnai’s tables warn that consumers should never attempt any action they are not qualified to perform (RU manual, p. 73; Value manual, p. 34). The V53De manual adds: call a licensed professional for any remedy that involves gas or electricity, or if you have any doubt about doing it yourself (V53De manual, p. 28). If you smell gas, the Value and V53De manuals put one step before those in the box above: leave the premises (Value manual, p. 28; V53De manual, p. 22).
- Check for anything restricting air flow around the heater and the vent terminal (Value manual, p. 34; RE manual, p. 50; VC manual, p. 37). On the outdoor V53De, check around the unit and its exhaust outlet (V53De manual, p. 29).
- If the heater is overheating, turn off the manual gas control valve to it, by hand only (RU manual, p. 8; Value manual, p. 3).
- Feel the water before a bath or shower. Rinnai warns that water above 125°F (52°C) can cause severe burns (RU manual, p. 70) and tells users to check the water temperature before entering a shower or bath (p. 7).
- Note the code history (RU manual, p. 73) and call for service if 16 comes back.
The tables give no separate reset step for code 16.
When to call a licensed technician
- The fan motor and the gas valve assembly (RU manual, p. 74). The guide also has the technician check that the check valve behind the fan motor is not stuck (troubleshooting guide, p. 27).
- Low water flow in a circulating system that causes short-cycling (Value manual, p. 34).
- Foreign material in the combustion chamber or exhaust piping, and blockage in the heat exchanger (Value manual, p. 34).
- On RE and REP models, the thermistor sensor and scale build-up on it (RE manual, p. 50).
- The gas type setting, which must match the gas type on the rating plate (troubleshooting guide, p. 27).
Notes for different models
The RE and REP tables use the shorter name “High Outgoing Temperature” (RE manual, p. 50). On every series, a separate code, 14, covers the overheat safety on the heat exchanger or the thermal fuse (RU manual, p. 73; RE manual, p. 50).
Related codes: 14, 61, 54. All Rinnai codes
Rinnai code 25 (condensate pump): what to check
Checked
Rinnai display
25
“Condensate Pump (Accessory)”
Short answer On Rinnai RU, RUR, RSC and RX heaters, code 25 means the accessory condensate pump's safety switch tripped. Check that the pump is plugged in and runs, its reservoir is empty and the drain line is clear; if 25 returns, call for service. See what to check
What it means
Code 25 concerns an accessory condensate pump on a condensing RU, RUR, RSC or RX heater (RU manual, p. 74). Rinnai calls for a condensate pump when there is no floor drain or the drain sits above the heater’s condensate drain (RU manual, p. 54). When a pump is installed, its safety switch is wired to the heater so that the heater shuts off if the pump fails (p. 55).
The troubleshooting guide says code 25 only appears when the condensate safety switch contacts are made, which happens when condensate backs up and trips the float switch, and that it may also occur if the pump stops working (p. 34). The installation test in the RU manual sets the code on purpose: with the pump unplugged and its reservoir filled until the float switch closes, the heater shows 25 (p. 55).
Check these first
- Check that the pump is plugged in. Rinnai says the field-supplied condensate pump should include an internal safety switch and a power cord, and that the power cord must be plugged into a power source (SENSEI RX Installation and Operation Manual, p. 41).
- Check that the pump’s reservoir is empty and that the pump runs (RU manual, p. 74).
- Check the condensate drain line: condensate flowing, the line not blocked, clogged or frozen, and its end open to the air (RU manual, pp. 76–77).
- The code 25 row gives no reset step (RU manual, p. 74). The RU manual’s installation test clears the code this way: turn off the heater with the On/Off button on the controller, wait five seconds, then turn the power back on (p. 55).
- If 25 comes back, call for service.
When to call a licensed technician
- The wire connections and harness between the pump and the heater (RU manual, p. 74). The safety switch wires come from inside the heater cover, and the wiring must conform to local codes and the National Electrical Code (RU manual, p. 55).
- Drain line work. Rinnai specifies corrosion-resistant material such as PVC pipe or plastic hose, a diameter at least that of the 1/2 in. drain connection, a slope toward the floor drain or pump, and an approved supplemental heat source on lines in areas subject to freezing (RU manual, p. 54).
- The condensate trap inside the heater and an air gap in the drain line, both on the troubleshooting guide’s list (p. 34).
Notes for different models
Code 25 appears only in the RU, RUR, RSC and RX/CX tables (RU manual, p. 74; SENSEI RX/CX Tech Sheet, p. 1), although the troubleshooting guide applies it to Non-SENSEI models as well (p. 34). The RE, REP, Value, V53De and VC tables have no code 25.
Related codes: 10, 54. All Rinnai codes
Rinnai code 61 (combustion fan): what to check
Checked
Rinnai display
61
“Combustion Fan”
Printed on 5 model series · 10 documents
Short answer Rinnai code 61 is a combustion fan fault. The fan sits inside the cabinet, so leave the front panel on and call a licensed technician. See what to check
What it means
Code 61 is a fault in the combustion fan; the troubleshooting guide titles it “Combustion Fan Motor” (p. 52). The fan is inside the cabinet: Rinnai’s instructions for cleaning dust from the fan blades begin with removing the front panel (RU manual, p. 76).
The remedies in the tables are checking the motor’s wire harness for loose or damaged connections, measuring resistance, and making sure the fan turns freely (RU manual, p. 74; RE manual, p. 51). The Value, V53De and VC tables mark all of them “licensed professional only” (Value manual, p. 35; V53De manual, p. 29; VC manual, p. 38). The RU, RX, RE and REP tables do not split remedies between owner and professional; in our reading, these are technician work there too, since the fan is inside the cabinet.
Check these first
The Value, V53De and VC tables give owners no steps for code 61. If you smell gas, the Value and V53De manuals put one step before those in the box above: leave the premises (Value manual, p. 28; V53De manual, p. 22). What an owner can do:
- To see how often 61 has appeared, view the code history. Turn the heater off with On/Off, hold On/Off for 2 seconds, then press Up; the last nine codes flash one after another (RU manual, p. 73; Value manual, p. 33).
- Leave the front panel on. Rinnai says not to operate the heater without it, and that it comes off only for service, maintenance or replacing internal parts (RU manual, p. 8).
- If the heater will not operate, turn off the gas to the appliance as the operating instructions describe, then call a service technician or the gas supplier (RU manual, p. 68; Value manual, p. 29).
When to call a licensed technician
Call for code 61 itself. The checks in the tables and the troubleshooting guide:
- The fan motor’s wiring harness and its connections back to the PC board (RU manual, p. 74; troubleshooting guide, p. 52).
- The resistance of the motor winding (RE manual, p. 51; Value manual, p. 35).
- Whether the blower wheel turns freely, and debris in the fan housing (troubleshooting guide, p. 52).
- On SENSEI and RX models, the check valve behind the fan motor, which must not stick closed (p. 52).
- The PC board, if the motor windings and fan voltage are within specification and the fan turns freely (p. 52).
The guide has the technician turn off power and gas before servicing the fan motor, and never plug or unplug the motor while the heater has power (p. 52). Rinnai also asks for the fan and motor to be kept free of dust and dirt by cleaning annually (RU manual, p. 76), as part of the maintenance it assigns to a trained and qualified professional (p. 76).
Notes for different models
Fan items show up under other codes as well. On SENSEI models, the code 10 remedies include fan debris and the check valve, and the code 16 remedies include the fan motor (RU manual, pp. 73–74).
Related codes: 10, 16. All Rinnai codes
Rinnai code 63 (recirculation low flow): what to check
Checked
Rinnai display
63
“Recirculation Low Flow”
Short answer On Rinnai RU, RUR, RSC, RX, RE and REP heaters, code 63 means recirculation low flow: too little water is moving through the recirculation loop. Clean the inlet water filter first, or have a professional do it; if 63 returns, call for service. See what to check
What it means
Code 63 is about the hot water recirculation loop: too little water is moving through it (RU manual, p. 74). The RX/CX tech sheet states that recirculation flow must be greater than 0.4 GPM (1.5 L/min) (p. 1).
The tables name the usual causes: a dirty inlet water filter, recirculation parameters set wrong, the pump’s supply voltage, and air in the recirculation line (RU manual, p. 74; RE manual, p. 51). The troubleshooting guide adds two more. On SENSEI and RX models, the heater shows 63 if parameter 04 is set for recirculation but no pump is connected. And a leak in the house plumbing can let the running pump draw air into the system (p. 54).
Check these first
- Clean the inlet water filter (RU manual, p. 74; RE manual, p. 51). Rinnai’s maintenance steps: close the cold and hot water isolation valves, put a bucket under the filter at the bottom of the heater, unscrew the filter, rinse off the debris, refit it and open the valves again (RU manual, p. 77; RE manual, p. 54). Before any maintenance, Rinnai says to turn off the electrical power, the gas at the manual gas control valve, and the incoming water supply (RU manual, p. 7). The troubleshooting guide adds that the heater should be drained before the inlet water filter is removed (p. 53). Rinnai also says repairs and maintenance shall be performed by a trained and qualified professional (RU manual, p. 76; RE manual, p. 53), so if you are not sure of any of these steps, leave the filter to one.
- To see how often 63 has appeared, view the code history. Turn the heater off with On/Off, hold On/Off for 2 seconds, then press Up; the last nine codes flash in turn (RU manual, p. 73).
- If 63 returns after the filter is clean, call for service. The tables give no separate reset step for this code.
When to call a licensed technician
- The recirculation parameter settings (RU manual, p. 74). Only trained and qualified professionals may adjust parameters (RU manual, p. 8). On RX models, if the recirculation water is not hot enough, the pump speed parameter (16A) should be set to Max (SENSEI RX/CX Tech Sheet, p. 1). The REP table adds a check of the pump speed settings (REP manual, p. 50).
- The pump’s supply voltage (RU manual, p. 74), which the guide gives as 120 VAC at the pump wiring harness (troubleshooting guide, p. 53), and the wiring between the pump and the PC board (RE manual, p. 51).
- Removing air from the recirculation line (RU manual, p. 74).
- On RU and RUR models in crossover (COV) mode, the bypass plug removed and a clean bypass filter installed (RU manual, p. 74).
- Loop length. The guide caps the recirculation loop’s equivalent length at 400 ft (122 m) with 3/4 in. pipe or 100 ft (30 m) with 1/2 in. pipe (troubleshooting guide, p. 54).
- Leaks in the house plumbing (p. 54).
Notes for different models
The RSC table drops the bypass plug and bypass filter items that the RU and RUR tables carry (RSC manual, p. 73). The Value, V53De and VC tables have no code 63, although the troubleshooting guide applies it to Non-SENSEI models too (p. 53).
Rinnai code 79 (water leak detected): what to do
Checked
Rinnai display
79
“Water Leak Detected”
Short answer On Rinnai RE, REP, Value and VC heaters, code 79 means water has been detected at the bottom of the unit. Turn off the water supply to the heater and contact a licensed professional; the checks are inside the cabinet. See what to check
What it means
Code 79 means water has been detected at the bottom of the unit (Value manual, p. 35). It appears in the RE, REP, Value and VC tables (RE manual, p. 51; REP manual, p. 50; VC manual, p. 38). The V53De table and the SENSEI RU, RUR, RSC and RX tables do not list it.
The troubleshooting guide’s checks show where the water can come from: the technician inspects the leak detector’s wiring, the heat exchanger and all piping inside the heater, and the bottom pan of the cabinet for pooled water (p. 62).
Check these first
- Turn off the water supply to the heater (RE manual, p. 51). Use the isolation valve immediately below the heater, or shut off the water supply to the building (Value manual, p. 3).
- Contact a licensed professional (RE manual, p. 51).
- If any part of the heater has been under water, do not use it. Rinnai asks for a licensed professional (Value manual, p. 3) or a qualified service technician (RE manual, p. 44) to inspect it and to replace any part of the control system and any gas control that was under water.
The tables give no reset step for code 79.
When to call a licensed technician
Everything after the water shut-off. The Value and VC tables put the whole remedy, including turning off the water and checking all plumbing inside the heater for leakage, in the “licensed professional only” column (Value manual, p. 35; VC manual, p. 38). The guide’s checks for the technician (p. 62):
- the leak detector’s wiring harness and connections;
- the heat exchanger and all piping inside the heater;
- water in the cabinet;
- the leak sensor itself.
A leaking heat exchanger also comes up under other codes. The SENSEI RU table lists a check that the heat exchanger is not leaking under code 72 (SENSEI RU Installation and Operation Manual, p. 75), and the guide’s Non-SENSEI steps for code 71 trace moisture in the plastic tubing between the combustion box and the gas valve to a leaking heat exchanger or to condensation from the vent system (troubleshooting guide, p. 59).
Notes for different models
The RE and REP tables address the shut-off to the owner: turn off the water supply and contact a licensed professional (RE manual, p. 51; REP manual, p. 50). The Value and VC tables shade the same step as licensed professional only (Value manual, p. 35; VC manual, p. 38). In both cases the repair belongs to a professional.
Related codes: 72, 71. All Rinnai codes
How to read a Rinnai code
The code appears on the temperature controller. Most Rinnai codes are two digits, such as 11 or 79. Three of the codes listed here are letters: LC (shown as LC0 to LC9) means scale build-up, SS is a time-based service reminder, and FF marks maintenance done by a service provider (Value manual, p. 35; RU manual, p. 75).
To see the last nine codes, turn the heater off with On/Off, hold On/Off for 2 seconds, then press Up while still holding it. Do the same to exit, then turn the heater back on (RU manual, p. 73). In the history, “00” stands for LC (RE manual, p. 52).
Code tables by manual: RU, pp. 73–75; RUR and RSC, pp. 72–74; RE, pp. 49–52; REP, pp. 48–51; Value (V65, V75, V94), pp. 34–35; V53De, pp. 28–29; VC (RL75, RL94, RLX94), pp. 37–38. The RX manual has no table and points to the tech data sheet inside the front cover (SENSEI RX Installation and Operation Manual, p. 58), quoted here from the SENSEI RX/CX Tech Sheet.
Clearing a code
Rinnai has no single reset. What the manuals say, code by code:
- 03: turn off all hot water taps, then press On/Off twice (RU manual, p. 73).
- 15 and 54: the RU table lists resetting the main power supply to the heater (RU manual, p. 74). For 15, the other remedies in that row, the venturi motor and the gas valve assembly, are technician work.
- 25: the table row has no reset step. The RU manual’s installation test clears the code by turning the heater off with On/Off, waiting five seconds and turning the power back on (RU manual, p. 55).
- SS: press On/Off five times within 5 seconds (RU manual, p. 75). On RX models the reset is holding the A button until SS disappears (SENSEI RX Installation and Operation Manual, p. 50). That button is on the PC board behind the front panel (p. 67), the panel comes off only for service or maintenance (p. 6), and the RX manual tells owners who see SS to contact their local service provider (p. 50).
- LC: five presses of On/Off keep the heater running until a flush (Value manual, p. 35). Clearing it after the flush differs by model; see the LC page.
If the heater will not operate, turn off the gas to the appliance and call a service technician or the gas supplier (RU manual, p. 68).
When to stop and call a professional
If you smell gas, do not light any appliance, touch an electrical switch or use a phone in the building. Call the gas supplier from a neighbor’s phone, or the fire department if you cannot reach the supplier (RU manual, p. 6). The Value and V53De manuals add “Leave the premises” (Value manual, p. 28; V53De manual, p. 22).
If the heater overheats or the gas does not shut off, turn off the manual gas control valve by hand, never with tools. Do not use the heater if any part has been under water (RU manual, p. 8).
Installation, service, the annual inspection and parameter changes belong to a trained and qualified professional (RU manual, pp. 6, 8, 76). The Value, V53De and VC tables mark many remedies “licensed professional only” (Value manual, p. 34). The troubleshooting guide behind the technician checks on these pages is for trained and qualified professionals only (Troubleshooting Tankless Water Heater Diagnostic Codes, p. 3).
See also
- Water heater size calculator
- 2029 water heater regulations: the DOE standard from May 6, 2029
- Furnace and HVAC tax credits for 2025 and 2026: 25C ended after 2025
- Form 5695 for 2025 and 2026: QMID, lines, carryforward
- How a tankless water heater lights: ignition codes by brand
- Home maintenance schedule from the manuals: monthly to yearly
- Winter home maintenance checklist: furnace, boiler, water heater
- Water heater or furnace closet: clearance and air requirements
Rinnai is a trademark of its owner. How House Works is not affiliated with or endorsed by Rinnai.
Sources
15 documents
- Rinnai America Corporation. Troubleshooting Tankless Water Heater Diagnostic Codes. 100000652(03), 5/2024; for trained and qualified professionals. Accessed Oct 12, 2026.
- Rinnai America Corporation. SENSEI RU Installation and Operation Manual. 100000467(07), 1/2021; cover title: Tankless Water Heater (Residential) Installation and Operation Manual; listed on rinnai.us as N Series Residential Condensing Installation and Operation Manual. Accessed Oct 12, 2026.
- Rinnai America Corporation. SENSEI RUR Installation and Operation Manual. 100000508(07), 1/2021; cover title: Tankless Water Heater (With Pump) Installation and Operation Manual. Accessed Oct 12, 2026.
- Rinnai America Corporation. SENSEI RSC Installation and Operation Manual. 100000773(01), 1/2023. Accessed Oct 12, 2026.
- Rinnai America Corporation. SENSEI RX Installation and Operation Manual. 100000839(03), 3/2025 (from PDF metadata; not printed). Accessed Oct 12, 2026.
- Rinnai America Corporation. SENSEI RX/CX Tech Sheet. 100000849, U362-0875(00); no printed date or page numbers (p. 1 is the PDF page). Accessed Oct 12, 2026.
- Rinnai America Corporation. SENSEI RX Spec Sheet. 100000883; no printed date. Accessed Oct 12, 2026.
- Rinnai America Corporation. RE Series Installation and Operation Manual. 100000722(03), 6/2022; cover title: Tankless Water Heater Installation and Operation Manual. Accessed Oct 12, 2026.
- Rinnai America Corporation. REP Series Installation and Operation Manual. 100000726(03), 3/2022; cover title: Tankless Water Heater (With Pump) Installation and Operation Manual. Accessed Oct 12, 2026.
- Rinnai America Corporation. Value Series Installation and Operation Manual. 100000258(10), 4/2021; cover title: Direct Vent Tankless Water Heater Installation and Operation Manual. Accessed Oct 12, 2026.
- Rinnai America Corporation. V53De Installation and Operation Manual. 100000561(05) (from the file name; no printed revision or date). Accessed Oct 12, 2026.
- Rinnai America Corporation. VC Series Installation and Operation Manual. 100000244(12), 8/2019; cover title: Direct Vent Tankless Water Heater Installation and Operation Manual. Accessed Oct 12, 2026.
- Rinnai America Corporation. TB-188 Optimized Flushing Procedure for SENSEI Tankless Water Heaters. Technical bulletin; no printed date. Accessed Oct 12, 2026.
- Rinnai America Corporation. TB-181 Higher Vinegar Concentration for Descaling. Technical bulletin; no printed date. Accessed Oct 12, 2026.
- Rinnai America Corporation. TB-166 Updates to PC Board Ignition Sequence. Technical bulletin; no printed date. Accessed Oct 12, 2026.