Rheem water heater blinking blue light: 1 blink is normal
How House Works EditorialChecked against 14 sources,
- Prepared by
- How House Works Editorial
- How it is checked
- Methodology
- Page
- HHW · ERROR-CODES · RHEEM-GAS-TANK · 1-BLINK
- Based on
- Rheem use and care manuals and the Maximus service manual
Short answer On Rheem, Ruud and Richmond status light models, one blue blink every three seconds is "Normal Operation": the pilot is lit. If the knob is still at PILOT, Rheem's fix is to set it to the temperature you want. See what to check
Status light, gas valve LED or display
1 blink
“Normal Operation”
Printed on 15 model series · 8 documents
What it means
One blue blink every three seconds is the code Rheem calls “Normal Operation”. The label legend prints it in blue, and the table under it reads “Normal Operation Temperature knob in pilot position and pilot is lit” (AP23060 Rev 01, p. 24). The label shows it as the “Normal Operation” example next to a “System Problem” example.
Two notes beside the legend tell you how to read the color: “If the Status Light is not blinking blue, relight the pilot.” and “If Status Light blinks red more than one flash every three seconds, see Use & Care Manual.” (AP23060 Rev 01, p. 24). Blinking is also how the lighting label tells you the pilot has caught: you hold the knob in until the STATUS light begins to blink, then check the flame through the sight glass (AP23060 Rev 01, p. 17).
The row describes the knob in the pilot position, and its only fix is to set the knob to the setting you want (AP23060 Rev 01, p. 24).
Check these first
- If you smell gas, stop and follow the steps at the top of this page.
- If the knob is still at PILOT, set it to the temperature you want; that is the table’s only step for this row (AP23060 Rev 01, p. 24). The control leaves the factory at its lowest setting, and the recommended starting point is 120°F (49°C) (AP23060 Rev 01, p. 18).
- Mind the scald risk. Water above 125°F (52°C) can cause severe burns or death from scalding, and households with small children, disabled or elderly persons may need a setting of 120°F or lower (AP23060 Rev 01, p. 18).
- To check the result, run a hot water faucet and hold a thermometer in the stream. Maximum water temperatures occur just after the burner has shut off (AP23060 Rev 01, p. 4).
- If the water is still not hot enough, the “Before You Call For Service” chart lists causes an owner can check: water usage may have exceeded the heater’s capacity, so wait for it to recover; the gas control may be set too low; or hot water faucets may be leaking or open, so make sure all of them are closed (AP23060 Rev 01, p. 23).
When to call a licensed technician
- Not for one blue blink by itself. The table gives it only the knob setting (AP23060 Rev 01, p. 24).
- Low gas pressure. The chart’s fix, “Check gas supply pressure and manifold pressure.”, is a gas measurement for a technician (AP23060 Rev 01, p. 23).
- A tripped combustion shutoff system. The chart lists it for not enough hot water and for a pilot that lights while the main burner will not stay lit, with “Contact a qualified service technician.” (AP23060 Rev 01, p. 23).
- Water that is too hot with the knob set correctly. The chart’s other cause is a defective gas control, replaced by a qualified service technician (AP23060 Rev 01, p. 23).
Notes for different models
All eight status light manuals print one blink as normal operation: AP23060 Rev 01, AP16801-2 (08/14), AP17110-1 (01/15), AP23698, AP23699, AP20849 Rev 02 and AP19928 Rev 02 on page 24, and AP22858 on page 23. AP17110-1 (01/15) prints no colors; its notes read “If the Status Light is not blinking, relight the Pilot.” and “If Status Light blinks more than one flash every three seconds, see Installation Instructions.” (AP17110-1, p. 24).
On power vent, powered damper and induced draft models, one flash of the gas valve LED is not normal operation:
| Indicator and manuals | One flash | Normal states |
|---|---|---|
| Power vent: AP22511 Rev 02, AP23058 Rev 01, AP23057 Rev 01, p. 37 | “Low flame signal” (LCD code 12) | Short flash once every four seconds; “heartbeat” |
| Powered damper: AP15756 (05/10), p. 24 | “Control still operating/ Low flame signal” | “Normal Operating Condition/ No Fault Condition”; “Calling For Heat/No Fault Conditions” |
| Induced draft: AP15696-3 (03/17), p. 28. Also the Ruud manual AP19361 (12/17), p. 32 | “Low flame signal (control continues to operate)” | “IDLE (no call for heat, no fault conditions)”; “Call For Heat (no fault conditions)” |
For low flame signal, the power vent table’s fixes are raising a low inlet gas supply pressure, raising low supply voltage to the rated voltage, and replacing the pilot assembly (AP22511 Rev 02, p. 37). All three are technician work.
Related Rheem gas tank water heaters codes
See also
- Water heater size calculator
- 2029 water heater regulations: the DOE standard from May 6, 2029
- Furnace and HVAC tax credits for 2025 and 2026: 25C ended after 2025
- Form 5695 for 2025 and 2026: QMID, lines, carryforward
- Gas water heater pilot won't stay lit: thermocouple, thermopile and the status light
- Home maintenance schedule from the manuals: monthly to yearly
- Winter home maintenance checklist: furnace, boiler, water heater
- Water heater or furnace closet: clearance and air requirements
All Rheem gas tank water heaters codes
Rheem, Ruud, Richmond are trademarks of their owners. How House Works is not affiliated with or endorsed by Rheem, Ruud, Richmond.
Sources
14 documents
- Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP23060 Rev 01. Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - Low NOx Emissions. AP23698. Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP22858. Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - Low NOx Emissions. AP23699. Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - Ultra Low NOx Emissions. AP19928 Rev 02. Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Residential 29, 30, 40, 50, 55 and 60 Gallon with Electronic Control, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters. AP16801-2 (08/14). Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Residential 28, 38, 40, 48 and 55 Gallon, Use & Care Manual, With Installation Instructions for the Installer, Water Heaters. AP17110-1 (01/15). Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - Ultra Low NOx Emissions. AP20849 Rev 02. Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Induced Draft, Residential Gas - FVIR Certified. AP15696-3 (03/17). Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Water Heaters, Residential Gas - Low NOx Emissions, FVIR Certified, Use & Care Manual. AP19361 (12/17). Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Residential 38, 40, and 50 Gallon, Residential Gas - FVIR Certified, With Damper & Electronic Control. AP15756 (05/10). Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP22511 Rev 02. Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP23058 Rev 01. Accessed Oct 26, 2026.
- Rheem Manufacturing Company. Use & Care Manual, With Installation Instructions for the Installer, Water Heaters, Residential Gas - FVIR Certified. AP23057 Rev 01. Accessed Oct 26, 2026.