Carrier furnace code 13 (1 short, 3 long): limit circuit lockout
Furnace control LED
13
“LIMIT CIRCUIT LOCKOUT”
Printed on 20 model series · 30 documents
What it means
Code 13 is one short flash followed by three long ones. On most Carrier, Bryant and Payne labels it is “LIMIT CIRCUIT LOCKOUT”: a limit or flame rollout switch stayed open longer than 3 minutes and the control locked out. The control resets itself after three hours, and the label sends you to code 33 for the causes 59SC5A-13SI, p. 67. Code 33 is the same open switch before those 3 minutes pass; after that, 33 changes to 13 59SC5A-13SI, p. 67.
On the 58STA, 58SB0A, 58SC0A, 820SA, 58TP0A and 58TN0A families the label also lists the draft safeguard and a blocked vent switch, if used 58SC0A-05SI, p. 26; 58TN0A-02SI, p. 35. On two-stage boards the lockout also follows 10 successive limit trips during high heat, and on the modulating 59MN7B during maximum heat 59TP6A-10SI, p. 73; 59MN7B-02SI, p. 73.
Check these first
Carrier’s owner’s manuals have no code table. These steps come from their general checklist, “Before you request a service call”, where it matches a cause the label gives for 13 or, through its “Refer to #33”, for 33.
- Write the code down before you turn off the power or remove the blower access door, as Carrier’s owner’s manual for condensing furnaces asks OM9GFRC-02, p. 10. Carrier’s 80% owner’s manual does not mention the LED. How to count the flashes: reading a Carrier code.
- Most labels list “Dirty filter or restricted duct system” under 33; the 59SU5A, Bryant 935SA, 59CU5A and Payne PG80ESU labels list it under 13 itself 59SC5A-13SI, p. 67; 59SU5A-05SI, p. 51; GFULN80-G-01TS, p. 6. The owner’s manual lets you check for a dirty air filter and for return-air or supply-air grilles that are blocked or closed OM9GFRC-02, pp. 10–11; 80GSFRN-C-03OM, p. 7. It says a dirty filter can make the furnace overheat and shut down automatically, and asks for the filter to be checked every four weeks OM9GFRC-02, p. 7.
- Through code 33, the label says the flame rollout switch requires a manual reset 59SC5A-13SI, p. 67. The owner’s manual gives you that step, behind the furnace door. First turn off the electrical power supply to the furnace and install a lockout tag before removing the access doors OM9GFRC-02, p. 10; Carrier’s 80% manual says to turn off the electrical power supply before removing the access doors 80GSFRN-C-03OM, pp. 5, 7. On condensing furnaces, push the button on the manual reset rollout switch on the burner box; if it trips again, shut down the furnace and call for service OM9GFRC-02, p. 11. Carrier’s 80% manual names manual reset limit switches on the ends of the burner enclosure, reset the same way; if one trips a second time, turn off the furnace and call for service 80GSFRN-C-03OM, p. 7. The 80% manual does not use the word rollout; this page treats those switches as the ones the label calls the flame rollout switch.
- The manual’s start-up steps replace the main furnace door before the electrical supply is turned on OM9GFRC-02, p. 5, steps 7 and 8.
- The label says the control clears the lockout itself after three hours 59SC5A-13SI, p. 67. If you shut the furnace down because of a malfunction, the owner’s manual says to call your dealer as soon as possible OM9GFRC-02, p. 6.
The 59SU5A, 935SA, 59CU5A and PG80ESU labels do not mention a rollout switch for code 13, so step 3 does not come from their labels 59SU5A-05SI, p. 51; 59CU5A-01SI, p. 65; GFULN80-G-01TS, p. 6. The 33 lists of the 59TP6A, 59TP6B and PG96VAT, the 59TN6B and 986TC, the 59MN7B and the 58MVP do not name the filter, so step 2 does not come from their labels 59TP6A-10SI, p. 73; 59TN6B-01SI, p. 60; 59MN7B-02SI, p. 73; 58-06T, p. 8.
When to call a licensed technician
- The rollout or limit switch trips again after you push the button OM9GFRC-02, p. 11; 80GSFRN-C-03OM, p. 7.
- The furnace still fails to operate after the checklist OM9GFRC-02, p. 11.
- The causes listed under 33 on most labels: a loose blower wheel, a defective blower motor or capacitor, a defective switch or its connections, a restricted vent, vent sizing, excessive wind, and inadequate combustion air supply when the flame rollout switch is open 59SC5A-13SI, p. 67. Two-stage and modulating labels list other items; see the code 33 page.
- On the 59SU5A, 935SA and 59CU5A, the 13 label lists a loose blower wheel, a restricted vent, vent sizing, a dirty filter or restricted duct system, and a defective switch or connections 59SU5A-05SI, p. 51; 59CU5A-01SI, p. 65. The PG80ESU guide adds excess wind and inadequate combustion air supply with the burner thermal switch open GFULN80-G-01TS, p. 6.
- The owner’s manual lets untrained people clean and replace air filters and says all other operations must be performed by trained service personnel OM9GFRC-02, p. 2.
Notes for different models
- The 58PAV and 58RAV Series 131 label calls 13 “LIMIT OR FLAME ROLLOUT SWITCH LOCKOUT”, with an automatic reset after three hours and a manual reset for the flame rollout switch 58P_R-9SM, p. 9.
- On the 59SU5A, 935SA and 59CU5A the label gives the condition as “Lockout occurs if a limit is open.”, with no 3-minute time 59SU5A-05SI, p. 51; 59CU5A-01SI, p. 65. On the PG80ESU it names a limit, the draft safeguard, the burner thermal switch or a blocked vent switch, if used GFULN80-G-01TS, p. 6.
- The 59SU5A, 935SA and 59CU5A also have code 26, “BURNER THERMAL SWITCH (BTS) open”, which the label describes as a permanent lockout if the switch is open during a call for heat 59SU5A-05SI, p. 51; 59CU5A-01SI, p. 65.
- Boards with a 3-digit display show 13.1, “Limit Lockout - switch open longer than 3 minutes in Main Limit circuit” 59TP6C-01SI, p. 56; IM-PG96VTAB-01, p. 54; 58SP0B-01SI, p. 30; II800SB-01, p. 31. On the Bryant 935SB it reads “Limit Lockout – switch opened in the limit circuit” II935SB-01, p. 48.
- The 58SU0A has no code 13. An open main limit circuit is 4 red flashes, with a 3-hour lockout 58SU0A-05SI, p. 36.
- The Infinity zone control lists furnace code 13; for 13 the system heats only with the heat pump, if there is one, until the code clears UIZ01-07SI, p. 20.
Related Carrier codes
See also
Other gas furnaces: Goodman, Lennox, Rheem and Ruud
Carrier is a trademark of its owner. How House Works is not affiliated with or endorsed by Carrier.
Sources
- Carrier Corporation. Owner's Manual, Condensing Gas Furnace. OM9GFRC-02, edition 04/20; replaces OM9GFRC-01. Accessed Oct 17, 2026.
- Carrier Corporation. Owner's Manual, Non-Condensing, 80% AFUE Gas Furnace. 80GSFRN-C-03OM, edition 08/22; replaces OM8GFRC-02. Accessed Oct 17, 2026.
- Carrier Corporation. SYSTXCCUIZ01--V Infinity Control (Zone), Installation Instructions. UIZ01-07SI, edition 05/12; replaces UIZ01-06SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58PAV, 58RAV Induced-Combustion Furnaces, Service and Maintenance Instructions, Sizes 045-155, Series 131. Form 58P,R-9SM (Catalog No. 535-835), edition 9-94; replaces 58P,R-8SM. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58MCB 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace, Service and Maintenance Instructions, Sizes 040-120, Series 110 & 120. 58MCB-4SM, edition 10/09; replaces 58MCB-3SM. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58STA/STX Single-Stage Deluxe, Induced-Combustion 4-Way Multipoise Gas Furnace, Series 160. 58ST-24SI, edition 08/13; replaces 58ST-23SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Payne Heating & Cooling. PG8MAA/PG8JAA Series G: Single-Stage Deluxe, Induced-Combustion 4-Way Multipoise Gas Furnace. IM-PG8J-17, edition 08/13; replaces IM-PG8J-16. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58SC0A/58SC1A: 80% AFUE, Single-Stage, Multi-Speed ECM, 4-Way Multipoise, Non-Condensing Gas Furnace. 58SC0A-05SI REV B, edition 09/21; replaces 58SC0A-05SI REV A. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58SB0A/58SB1A: Single Stage, Multi-Speed ECM, Non-Condensing Gas Furnace, Input Capacities 45,000 thru 155,000 Btuh. 58SB0A-04SI, edition 03/20; replaces 58SB0A-03SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 810SA/811SA: 80% AFUE, Single-Stage, Multi-Speed ECM, 4-Way Multipoise, Non-Condensing Gas Furnace. II810SA-05 REV B, edition 09/21; replaces II810SA-05 REV A. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Payne Heating & Cooling. PG80ESAA/PG80ESLA: 80% AFUE, Single-Stage, Multi-Speed ECM, 4-Way Multipoise, Non-Condensing Gas Furnace. IM-PG80ESA-05 REV B, edition 08/21; replaces IM-PG80ESAA-05 REV A. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Payne Heating & Cooling. PG80ESAA/PG80ESLA: Single Stage, Multi-Speed ECM, Non-Condensing Gas Furnace, Input Capacities 45,000 thru 155,000 Btuh. IM-PG80ESAA-04, edition 03/20; replaces IM-PG80ESAA-03. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 820SA/821SA: 80% AFUE, Non-Communicating, Single Stage, ECM Motor, Variable Speed, 4-Way Multipoise, Non-Condensing Gas Furnace. II820SA-02 REV A, edition 08/21; replaces II820SA-02. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58TP0A/58TP1A Variable-Speed, ECM Induced-Combustion, 2-Stage 4-Way Multipoise, Non-Condensing Gas Furnace, Series A. 58TP0A-02SI, edition 07/19; replaces 58TP0A-01SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58TN0A/58TN1A: 80% AFUE, Two-Stage, Variable-Speed 4-Way Multipoise, Non-Condensing Gas Furnace, Series A. 58TN0A-02SI REV A, edition 08/21; replaces 58TN0A-02SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 880TA/881TA: 80% AFUE, Two-Stage, Variable-Speed 4-Way Multipoise, Non-Condensing Gas Furnace, Series A. II880TA-02 REV A, edition 08/21; replaces II880TA-02. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SC2D Single Stage, 35-in. (889 mm) Tall 4-Way Multipoise Condensing Gas Furnace. 59SC2D-02SI, edition 11/19; replaces 59SC2D-01BSI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SC5A Single Stage 4-Way Multipoise Condensing Gas Furnace, Series 1 and 2. 59SC5A-13SI, edition 01/19; replaces 59SC5A-12SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SP5A Single Stage, 4-Way Multipoise Condensing Gas Furnace, Series 1 and 2. 59SP5A-18SI, edition 01/19; replaces 59SP5A-17SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SC5B: Single-Stage, High Efficiency, 4-Way Multipoise, 35-in. (889 mm), Condensing Gas Furnace. 59SC5B-04SI REV E, edition 06/23; replaces 59SC5B-04SI REV D. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SP6A: Single-Stage, Non-Communicating, Variable-Speed, ECM Multipoise, Condensing Gas Furnace. 59SP6A-01SI REV D, edition 06/23; replaces 59SP6A-01SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59TP6A Two-Stage Variable Speed ECM Multipoise Condensing Gas Furnace, Series 2, All Series 3 80-20, 100-20, 120-22. 59TP6A-10SI, edition 11/18; replaces 59TP6A-09SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59TP6B: Installation, Start-up, Operating and Service and Maintenance Instructions. 59TP6B-04SI REV D, edition 06/23; replaces 59TP6B-04SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 19, 2026.
- Payne Heating & Cooling. PG96VAT: Two-Stage 4-Way Multipoise Condensing Gas Furnace, Series B, All Series C, Sizes 60080, 60100, 66120. IM-PG96VAT-13, edition 11/18. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59TN6B: Two-Stage, Variable-Speed, Multipoise, 35 in. (889 mm) Tall, Condensing Gas Furnace. 59TN6B-01SI REV D, edition 06/23; replaces 59TN6B-01SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 986TC: Two-Stage, Variable-Speed, Multipoise, 35 in. (889 mm) Tall, Condensing Gas Furnace. II986TC-01 REV D, edition 06/23; replaces II986TC-01 REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59MN7B: Modulating, High Efficiency Condensing Gas Furnace, 4-Way Multipoise. 59MN7B-02SI REV D, edition 06/23; replaces 59MN7B-02SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SU5A: Up to 95% AFUE, Single-Stage, Upflow/Horizontal, Ultra Low NOx, 35-in. Tall, Condensing Gas Furnace (Minor Series 2). 59SU5A-05SI REV D, edition 06/23; replaces 59SU5A-05SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 935SA: Up to 95% AFUE, Single-Stage, Upflow/Horizontal, Ultra Low NOx, 35-in. Tall, Condensing Gas Furnace (Minor Series B). II935SA-05 REV D, edition 06/23; replaces II935SA-05 REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59CU5A: Single-Stage, Upflow/Horizontal Communicating, Variable Speed ECM, Ultra Low NOx, 35-in Tall Condensing Gas Furnace. 59CU5A-01SI REV D, edition 06/23; replaces 59CU5A-01SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58SU0A 4-Way Multipoise, Ultra Low NOx 80% AFUE Gas Furnace, Input Capacities 40,000 thru 100,000 Btuh. 58SU0A-05SI, edition 11/19; replaces 58SU0A-04SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Payne Heating & Cooling. PG80ESU (Minor Series B&C) Troubleshooting Guide: 80% AFUE, Ultra Low NOx, 4-Way Multipoise Gas Furnace. GFULN80-G-01TS, edition 08/23. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. Troubleshooting Guide: Mid-Efficiency Variable-Speed, Two-Stage Induced-Combustion Deluxe, 4-Way Multipoise Gas Furnace. TG-GFC80-02, edition 05/18; replaces TG-GFC80-01. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59MN7A Series 100 Troubleshooting Guide: Variable Speed, Modulating Electronic Condensing Four-Way Multipoise Gas Furnace. Form 59MN7A-01T, edition 9-11. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 19, 2026.
- Carrier Corporation. 58MVP Series 170 & 180, 58MVB, 58UVB Troubleshooting Guide: Variable Speed, Two-Stage Electronic Condensing Gas Furnace. Form 58-06T, edition 6-08; replaces 58MVP-10SM. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 19, 2026.
- Carrier Corporation. 59TP6C: Two-Stage, Non-Communicating, Variable 25-Speed, ECM Multipoise, Condensing Gas Furnace with InteliSense. 59TP6C-01SI REV A, edition 06/23; replaces 59TP6C-01SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Payne Heating & Cooling. PG96VTAB: Two-Stage, Non-Communicating, Variable 25-Speed, ECM Multipoise, Condensing Gas Furnace. IM-PG96VTAB-01 REV A, edition 06/23; replaces IM-PG96VTAB-01. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58SP0B/58SP1B: 80% AFUE, Non-Communicating, Single Stage, Variable 25-Speed, ECM Motor, 4-Way Multipoise, Non-Condensing Gas Furnace with InteliSense. 58SP0B-01SI, edition 03/23. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 800SB/801SB: 80% AFUE, Single Stage, Multi-Speed ECM, 4-Way Multipoise, Non-Condensing Gas Furnace. II800SB-01 REV B, edition 06/23; replaces II800SB-01 REV A. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 935SB: Installation, Start-up, Operating and Service Maintenance Instructions (single-stage ultra low NOx condensing; 3-digit display). II935SB-01 REV C, edition 06/23; replaces II935SB-01 REV B. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 19, 2026.