Rheem and Ruud furnace code 0: standby, not a fault
Furnace control display or LED
0
“Standby”
Printed on 13 model series · 13 documents
What it means
0 is the display at rest. Rheem’s manuals say that in standby mode with no fault codes present the display reads 0 (zero) 92-24161-144-09, p. 39. The normal operation code cards define it as no fault present and no thermostat call present: the furnace is idle 95P: 92-24161-111-17, p. 87; 96V: 92-24161-124-12, p. 111.
Any fault takes its place. In the 96P code list 0 has the lowest priority, 24, and the control shows a lower priority number over a higher one 92-24161-122-12, p. 88; 92-24161-157-00, p. 88. When the thermostat calls, 0 changes to a mode letter: H for gas heat, h for low gas heat on two-stage furnaces, C for cooling or heat-pump heat, F for continuous fan 92-24161-144-09, p. 39; 92-24161-122-12, p. 88. On the communicating furnaces 0 also shows while the blower runs its off-delay after heating or cooling 92-24161-124-12, p. 93.
So a furnace that shows 0 and is not heating has no call for heat present at the control and no fault on the display. During a lockout the control shows the lockout code, even in place of C or F when it answers a cooling or fan call 92-24161-144-09, p. 40.
Check these first
From Rheem’s owner’s manuals for condensing and 80% furnaces, in their order 92-20802-128-03, p. 4; 92-20802-130-02, p. 4:
- Keep heat from a television, lamps or radios away from the thermostat: the manual asks you not to let it influence the thermostat’s operation 92-20802-128-03, p. 4.
- The manuals describe the thermostat’s switches: HEAT turns heating on when the temperature drops below the desired temperature, AUTO turns heating or cooling on as needed to hold the desired temperature, and OFF turns heating and cooling off. They do not tell the owner to check them when the furnace is not heating 92-20802-128-03, p. 4.
- If the furnace will not operate, the last of the operating instructions is to turn off the gas to the furnace by “To Turn Off Gas To The Appliance” and call your service technician or gas supplier 92-20802-128-03, p. 4. The steps, with the manual’s warning to turn off electrical power before removing the front access door 92-20802-128-03, p. 7, are under shutting the furnace down.
The owner’s manuals do not mention the display or its codes (92-20802-128-03; 92-20802-130-02).
When to call a licensed technician
- The furnace will not operate. The owner’s manual’s step is to turn off its gas and call your service technician or gas supplier 92-20802-128-03, p. 4.
- A code replaces the 0. Read it with the rows for your series; pages for 57, 45, 22, 93, 61, 66 and 68 are linked from the Rheem and Ruud code list.
- Anything past the filter: the owner’s manuals leave routine maintenance to a qualified installer, service agency or the gas supplier 92-20802-128-03, p. 7.
Notes for different models
| Series | Where | Wording | Source |
|---|---|---|---|
| 92P, 92T, 95P, 95T, 96P, 96T, 801S, 801P, 801T, 802P | code list | “STANDBY” | 92-24161-111-17, p. 87; 92-24161-122-12, p. 88; 92-24161-144-09, p. 39; 92-24161-146-05, p. 40 |
| 92P to 96T 2017 revisions, 96V, 97V, 98V, 802V, 801T Ultra Low NOx | normal operation code card | “STANDBY MODE” | 92-24161-111-17, p. 87; 92-24161-124-12, p. 111; 92-24161-164-01, p. 32 |
| 96V | diagnostics chart | “System Off, Standby Mode no Thermostat Calls or Errors.” | 96V-chart |
| 97V, 98V | diagnostics chart | “System Off, Standby Mode No Thermostat Call Or Errors” | 97V-chart |
| Fault code label 92-103343-01-00 (listed on the RGGE and RGJF support pages) | label, no models printed | “Standby” | 92-103343-01-00, p. 1 |
The 801T Ultra Low NOx card title was read from the page image 92-24161-164-01, p. 32. On the diagnostics charts 0 has fault level 0, which the 97V chart defines as “Status (No Fault)” (96V-chart; 97V-chart). The troubleshooting legends in the installation instructions print standby as the letter O, while the code lists use the digit 0 92-24161-144-09, pp. 39, 50.
On the communicating furnaces the mode letter follows the thermostat’s demand: a first-stage call shows h even though the furnace ignites at high stage 92-24161-124-12, p. 92. The green LED blink legend of the RGPN, RGPS, RGLN and RGLS instructions has no 0; its codes are blink counts (92-24161-38-12, p. 39; 3 blinks, 2 blinks).
For Ruud, the documents show only the replacement-parts line “www.myrheem.com/myruud.com” in the 802P manuals 92-24161-146-05, p. 50; 92-24161-147-04, p. 46 and the model name R801T on both a Ruud and a Rheem specification sheet (G22-556 Rev 8; G11-662 Rev 7); none ties a Ruud furnace to a series on this page.
Related Rheem and Ruud codes
See also
Rheem and Ruud is a trademark of its owner. How House Works is not affiliated with or endorsed by Rheem and Ruud.
Sources
- Rheem Manufacturing. USER'S INFORMATION MANUAL UPFLOW/DOWNFLOW/HORIZONTAL CONDENSING GAS FURNACES. 92-20802-128-03 SUPERSEDES 92-20802-128-02; listed July 2017. Accessed Oct 20, 2026.
- Rheem Manufacturing. USER'S INFORMATION MANUAL UPFLOW/DOWNFLOW/HORIZONTAL 80% GAS FURNACES. 92-20802-130-02 SUPERSEDES 92-20802-130-01. Accessed Oct 20, 2026.
- Rheem Manufacturing. Specification sheet, Endeavor Line Classic Series gas furnaces, R801T UH. G11-662 Rev 7. Accessed Oct 20, 2026.
- Rheem Manufacturing. Specification sheet, R801T upflow/horizontal series, 80% AFUE. G22-556 Rev 8. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR 4 POSITION CONDENSING SINGLE STAGE SINGLE-STAGE GAS FURNACES (-)92P SERIES & (-)(-)92MSP SERIES. 92-24161-118-16 SUPERSEDES 92-24161-118-15; listed December 2017. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR 4 POSITION CONDENSING SINGLE STAGE GAS FURNACES WITH CONSTANT-TORQUE AIR CIRCULATING BLOWER (-)92T SERIES & (-)(-)92MSX SERIES. 92-24161-154-03 SUPERSEDES 92-24161-154-02; listed December 2017. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR 4 POSITION CONDENSING SINGLE STAGE SINGLE-STAGE GAS FURNACES (-)95P SERIES, (-)(-)95MSP SERIES. 92-24161-111-17 SUPERSEDES 92-24161-111-16; listed November 2017. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR 4 POSITION CONDENSING SINGLE STAGE GAS FURNACES WITH CONSTANT-TORQUE AIR CIRCULATING BLOWER (-)95T SERIES & (-)(-)95MSX SERIES. 92-24161-120-16 SUPERSEDES 92-24161-120-15; listed December 2017. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR 4 POSITION CONDENSING TWO-STAGE, PSC GAS FURNACES (-)96P SERIES & (-)(-)96MDP SERIES. 92-24161-122-12 SUPERSEDES 92-24161-122-11; listed December 2017. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR 4 POSITION CONDENSING TWO-STAGE, CONSTANT TORQUE GAS FURNACES (-)96T SERIES & (-)(-)96MDT SERIES. 92-24161-157-04 SUPERSEDES 92-24161-157-03; listed December 2017. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR UPFLOW/HORIZONTAL SINGLE STAGE GAS FURNACES (-)801S UPFLOW/HORIZONTAL SERIES (-)801P UPFLOW/HORIZONTAL SERIES (-)(-)80MSS UPFLOW/HORIZONTAL SERIES (-)(-)80MSP UPFLOW/HORIZONTAL SERIES. 92-24161-142-15 SUPERSEDES 92-24161-142-14; listed May 2018. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR DOWNFLOW SINGLE STAGE GAS FURNACES (-)801S DOWNFLOW SERIES (-)801P DOWNFLOW SERIES (-)(-)80DSS DOWNFLOW SERIES (-)(-)80DSP DOWNFLOW SERIES. 92-24161-143-14 SUPERSEDES 92-24161-143-13; listed May 2018. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR UPFLOW/HORIZONTAL SINGLE STAGE GAS FURNACES WITH CONSTANT-TORQUE AIR CIRCULATION BLOWER (-)801T UPFLOW/ HORIZONTAL SERIES (-)(-)80MSX UPFLOW /HORIZONTAL SERIES. 92-24161-144-09 SUPERSEDES 92-24161-144-08; listed December 2017. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR DOWNFLOW SINGLE STAGE GAS FURNACES WITH CONSTANT TORQUE AIR CIRCULATING BLOWER (-)801T DOWNFLOW SERIES (-)(-)80DSX DOWNFLOW SERIES. 92-24161-145-10 SUPERSEDES 92-24161-145-09; listed December 2017. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR UPFLOW/HORIZONTAL TWO STAGE PSC GAS FURNACES (-)802P UPFLOW/HORIZONTAL SERIES (-)(-)80MDP UPFLOW/HORIZONTAL SERIES. 92-24161-146-05 SUPERSEDES 92-24161-146-04; listed December 2014. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR DOWNFLOW TWO STAGE PSC GAS FURNACES (-)802P DOWNFLOW SERIES (-)(-)80DDP DOWNFLOW SERIES. 92-24161-147-04 SUPERSEDES 92-24161-147-03; listed December 2014. Accessed Oct 20, 2026.
- Rheem Manufacturing. Serial Communicating Gas Furnace Fault Code Label (sheet “FAULT CODES”). 92-103343-01-00. Accessed Oct 20, 2026.
- Rheem Manufacturing. Diagnostics chart “DISPLAY CODES” (97V_ Trouble-Shooting_Chart.pdf, linked from the R97V and R98V pages). 97V-chart. Accessed Oct 20, 2026.
- Rheem Manufacturing. Diagnostics chart, untitled (96V_Trouble-Shooting_Chart.pdf, linked from the R96V page). 96V-chart. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR 4 POSITION CONDENSING TWO-STAGE, COMMUNICATING GAS FURNACES W/ECM BLOWER (-)96V SERIES & (-)(-)96MDV SERIES. 92-24161-124-12 SUPERSEDES 92-24161-124-11; listed December 2017. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR UPFLOW/HORIZONTAL SINGLE STAGE ULTRA LOW NOx (LESS THAN 14 ng/J) GAS FURNACES WITH CONSTANT-TORQUE AIR CIRCULATION BLOWER (-)801T UPFLOW SERIES. 92-24161-164-01; listed July 2018. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR 4 POSITION CONDENSING TWO-STAGE, CONSTANT TORQUE GAS FURNACES (-)96T SERIES & (-)(-)96MDT SERIES. 92-24161-157-00; listed September 2016. Accessed Oct 20, 2026.
- Rheem Manufacturing. INSTALLATION INSTRUCTIONS FOR UPFLOW/HORIZONTAL & DOWNFLOW INDUCED DRAFT GAS FURNACES RGPN/RGPS UPFLOW/HORIZONTAL SERIES RGLN/RGLS DOWNFLOW SERIES. 92-24161-38-12 SUPERSEDES 92-24161-38-11; listed April 2012. Accessed Oct 20, 2026.