Goodman furnace code EE0: ignition lockout and how to reset it

By How House Works EditorialBased on Goodman service manuals and installation instructionsChecked against sources Updated

Furnace control display or LED

EE0

“Furnace lockout due to an excessive number of ignition “retries” (3 total)”

Printed on 21 model series · 20 documents

GR9S92 / GR9S96 / GD9S96, A/GR9S96*U* Ultra-Low NOx, GR9S80 / GD9S80 / AR9S80 / AD9S80, A/GR9S80*U* Ultra-Low NOx, VR9S80/VD9S80, GR9T96 / GD9T96 / AR9T96 / AD9T96, GR9T80 / GD9T80 / AR9T80 / AD9T80, GRVT80 / GDVT80 / ARVT80 / ADVT80, GM9S92 / GM9S96 / GC9S96, GM9S80 / GC9S80 / AM9S80 / AC9S80 / VM9S80 / VC9S80, *M9S96*U; *M9S80*U, GM9C96 / GC9C96 / AM9C96 / AC9C96, GM9C80 / GC9C80 / AM9C80 / AC9C80, GMVC96*BB / GCVC96*BB, GMVC96*BA, GMVC80*AC / GCVC80*AC / ACVC80*AC / AMVC80*AC, GMVC8 / AMVC8 / ADVC8; ACVC8 / GCVC8, GMVM97*BA / GCVM97, *MVS80*U ; CCVS80; *MVS96; CCVS96, *MES96*U, GMES80*U / AMES80*U · IOG-2037A p. 41; RS6612302 p. 31; RS6621301 p. 34; RS6621302 p. 28; RS6612304 p. 27; RS6621304 p. 35; RS6621305 p. 43; IOG-2029D p. 39; IOG-2030B p. 28; IOG-2032C p. 37; IOG-2027E p. 46; IOG-2026B p. 30; IOG-2015L p. 48; RS6612014R3 p. 60; IOG-2023E p. 33; IOG-2016A p. 36; IOG-2017H p. 46; IOG-2034A p. 35; RS6612017R4 p. 30; RS6621006R4 p. 33

Owner checks, then technician

What it means

EE0 is a lockout. The control tried to light the burners three times without success: either no flame was established, or the flame was lost after it was established IOG-2037D, p. 43. The furnace does not run RS6612301, p. 36. Goodman’s owner’s manual describes a lockout as a non-functioning furnace, with the circulator blower possibly running continuously, “providing a diagnostic LED code” HIG-2002A, p. 6. For boards with a display, the GRVT96 installation instructions tie lockout to this code: a non-functioning furnace and “an EE0 code displayed on the 7-segment display” IOG-2044B, p. 45.

The current table lists these possible causes: no gas or improper gas pressure to the burners, a bad igniter or igniter alignment, restricted orifices, a coated, oxidized or improperly connected flame sensor, a restriction in the flue or a lack of combustion air, and improper induced draft blower performance IOG-2037D, p. 43.

Check these first

Goodman’s owner’s manual has no code table, but it has a section on lockouts. Its troubleshooting section is written for a flashing LED and does not mention the three-character display HIG-2002A, p. 8.

  1. Write the code down before you open anything; the manual’s first step, written for the LED, is to record the flashes HIG-2002A, p. 8. See how to read a Goodman code.
  2. Reset the lockout by one of the three methods in the owner’s manual HIG-2002A, p. 6: wait for the control to reset itself after the one-hour lockout period; interrupt the 115 volt power to the furnace for more than 20 seconds; or interrupt the thermostat signal to the furnace for between 0 and 20 seconds.
  3. If the condition that caused the lockout is still there, the control locks out again. If the furnace locks out often, the manual says a problem exists that must be corrected and to contact a qualified servicer HIG-2002A, p. 6.
  4. For a code that stays, the troubleshooting section says to shut the furnace down and contact a qualified servicer HIG-2002A, p. 8. The shut-down: thermostat to its lowest setting, then, behind the burner compartment door, the gas valve’s ON/OFF switch to OFF, the external manual gas shut-off valve closed, and the door back on HIG-2002A, p. 6. Before the gas control goes to OFF, the start-up steps and the label also turn off the electrical power to the furnace; the label says to do so if service is to be performed HIG-2002A, pp. 6, 9. Move the gas control by hand only, never with tools HIG-2002A, p. 9. Full steps: shutting the furnace down.

Do not go further than this: “Do not attempt repairs yourself” HIG-2002A, p. 8, and “do not remove any internal compartment covers” HIG-2002A, p. 6.

When to call a licensed technician

  • The lockout comes back after a reset, or happens often HIG-2002A, p. 6.
  • The gas supply and gas pressure to the burners. The table’s first corrective action is to locate and correct a gas interruption IOG-2037D, p. 43.
  • The igniter: replacing or realigning it IOG-2037D, p. 43. The GMVC96*BA service manual adds that the igniter is fragile RS6612014R3, p. 60.
  • The flame sensor: checking the flame sense signal and cleaning the sensor if it is coated or oxidized IOG-2037D, p. 43.
  • The front cover pressure switch and drainage, the flue piping (blockage, length, elbows, termination) and the induced draft blower IOG-2037D, p. 43.
  • Any service or maintenance. The owner’s manual says to disconnect electrical power before performing it HIG-2002A, p. 7, and that maintenance is for a qualified service technician HIG-2002A, p. 6.

Notes for different models

Board or series Code Wording in the table Source
Most three-character boards (GR9, GM9, VR9 and GMVC96 lines; MES96U and GMES80*U from the March 2023 manuals) EE0 “Furnace lockout due to an excessive number of ignition “retries” (3 total)” IOG-2029D, p. 39; RS6612017R4, p. 30
ComfortNet alarm tables (GMVC96BA, GMVC96BB, GMVC80AC, GMVM97BA, GRVT96, GRVT80, GRVM97) EE0 “Lockout Due to Excessive Retries or Recycles” RS6612014R3, p. 56; RS6612305, p. 39
Single-LED boards (GMSS9, GMES9, GMES80, GKS9, GMS8 and others) 1 flash Same lockout after 3 ignition retries IOG-2009Q, p. 42
GMEC96, GMEC80 Red 7 flashes “Lockout - excessive retries from flame not being proven during trial for ignition” IOG-2011U, p. 55 (GMEC96); RS6621005R1, p. 29 (GMEC80)
GMEC96, GMEC80 Red 8 flashes “Lockout - excessive recycles from flame proving being lost after being proven” IOG-2011U, p. 55 (GMEC96); RS6621005R1, p. 29 (GMEC80)
MES96U, GMES80*U, 2019 manuals Red 1 flash Lockout after 3 ignition attempts RS6612017, p. 20; RS6621006, p. 16
Older ComfortNet two-character boards E0 (thermostat: LOCKOUT) Same lockout after 3 ignition retries RS6612010R6, p. 47

Reset times differ between documents. The owner’s manual gives more than 20 seconds without power, or 0 to 20 seconds without the thermostat signal HIG-2002A, p. 6. The GR9T96 installation instructions give 1 to 20 seconds for both IOG-2038E, p. 46. The GMVC96*BA service manual gives no time for the power method and describes the thermostat method as lowering the thermostat so there is no call for heat for 1 to 20 seconds, then setting it back RS6612014, p. 72. All of them have the automatic reset after one hour. These pages follow the owner’s manual.

Older editions of the owner’s manual (HI-115C, 02/12; HIG-2002, 07/19) had one more check: that the manual gas shut-off valve outside the furnace is ON, and if it is OFF, turning the gas on by following the start-up steps HI-115C, p. 8; HIG-2002, p. 8. The current edition, HIG-2002A (09/19), no longer has this check HIG-2002A, p. 8, and this page does not recommend it. The start-up steps include a five-minute wait to clear out gas and a smell check near the floor; if you smell gas after that wait, the manual says to immediately follow the instructions on its cover HIG-2002A, p. 6.

Two documents describe the lockout display differently from their own tables. The GR9T96 installation instructions say a lockout shows as a one flash diagnostic LED code, while their table gives EE0 IOG-2038E, pp. 45, 49. The GMVC96*BA service manual describes the code on a “dual 7-segment display” RS6612014, p. 72.

Related Goodman codes

See also

Other gas furnaces: Carrier, Lennox, Rheem and Ruud

All Goodman codes

Goodman is a trademark of its owner. How House Works is not affiliated with or endorsed by Goodman.

Sources

  1. Goodman Manufacturing. Gas-Fired Warm Air Furnace User's Information Manual. HIG-2002A, 09/19. Accessed Oct 17, 2026.
  2. Goodman Manufacturing. Gas-Fired Warm Air Furnace User's Information Manual. HIG-2002, 07/19. Accessed Oct 17, 2026.
  3. Goodman Manufacturing. GAS-FIRED WARM AIR FURNACE USER'S INFORMATION MANUAL. HI-115C, 02/12. Accessed Oct 17, 2026.
  4. Goodman Manufacturing. Service manual: 34.5" Chassis ACVC96/AMVC96 GCVC96/GMVC96 Gas Furnaces. RS6612010R6, November 2017. Accessed Oct 19, 2026.
  5. Goodman Manufacturing. Installation Instructions for *DVT96* & *RVT96* Two-Stage Gas Furnace. IOG-2044B, 10/2026. Accessed Oct 17, 2026.
  6. Goodman Manufacturing. Installation Instructions for *R9S96/*D9S96 & *R9S92 Single-Stage Gas Furnace. IOG-2037D, 10/2026. Accessed Oct 17, 2026.
  7. Goodman Manufacturing. Installation Instructions for *R9T96 & *D9T96 Two-Stage Gas Furnaces. IOG-2038E, 07/2026. Accessed Oct 17, 2026.
  8. Goodman Manufacturing. Service manual: 34.5" Chassis ACVC96*BA/AMVC96*BA GCVC96*BA/GMVC96*BA Gas Furnaces (BA revision & above). RS6612014R3, October 2020. Accessed Oct 19, 2026.
  9. Goodman Manufacturing. Installation Instructions for *R9S96/*D9S96 & *R9S92 Single-Stage Gas Furnace. IOG-2037A, 09/2023. Accessed Oct 17, 2026.
  10. Goodman Manufacturing. Service manual: 96% Single Stage Ultra-Low NOx Gas Furnaces A/GR9S96*U*. RS6612302, January 2025. Accessed Oct 17, 2026.
  11. Goodman Manufacturing. Service manual: 80% Single Stage Ultra-Low NOx Gas Furnaces A/GR9S80*U*. RS6621302, October 2024. Accessed Oct 17, 2026.
  12. Goodman Manufacturing. Service manual: GR9S92 / GR9S96 / GD9S96 / AR9S92 / AR9S96 / AD9S96 / VM9S96 / VC9S96 Single Stage Gas Furnaces and Accessories. RS6612301, May 2024. Accessed Oct 17, 2026.
  13. Goodman Manufacturing. Service manual: Goodman Brand GR9T96/GD9T96 & Amana Brand AR9T96/AD9T96 Two Stage Furnace with Nine speed ECM Motor. RS6612304, May 2024. Accessed Oct 17, 2026.
  14. Goodman Manufacturing. Service manual: Goodman Brand GR9T80/GD9T80 & Amana Brand AR9T80/AD9T80 Two Stage Furnace with Nine Speed ECM Motor. RS6621304, December 2023. Accessed Oct 17, 2026.
  15. Goodman Manufacturing. Installation Instructions for *M9S96/*C9S96 & *M9S92 Single-Stage Gas Furnace. IOG-2029D, 07/2023. Accessed Oct 17, 2026.
  16. Goodman Manufacturing. Installation Instructions for *M9S80 & *C9S80* Gas Furnace. IOG-2030B, 04/2022. Accessed Oct 17, 2026.
  17. Goodman Manufacturing. Installation Instructions for *M9C96 & *C9C96 Two-Stage Gas Furnaces. IOG-2027E, 07/2023. Accessed Oct 17, 2026.
  18. Goodman Manufacturing. Installation Instructions for *M9C80 & *C9C80* Gas Furnace. IOG-2026B, 04/2022. Accessed Oct 17, 2026.
  19. Goodman Manufacturing. Installation Instructions for *CVC96*BB & *MVC96*BB Two-Stage Gas Furnace. IOG-2015L, 06/2023. Accessed Oct 19, 2026.
  20. Goodman Manufacturing. Installation Instructions for *MVC8*CA & *CVC8*CA Gas Furnace. IOG-2016A, 07/2019. Accessed Oct 17, 2026.
  21. Goodman Manufacturing. Installation Instructions for *CVM97*B* & *MVM97*B* Modulating Gas Furnace. IOG-2017H, 07/2023. Accessed Oct 19, 2026.
  22. Goodman Manufacturing. Installation Instructions for CCVS96 Ultra Low NOx Variable Speed Gas Furnace. IOG-2034A, 6/2023. Accessed Oct 17, 2026.
  23. Goodman Manufacturing. Installation Instructions for *M9S96*U Ultra Low NOx Gas Furnace. IOG-2032C, 07/2023. Accessed Oct 17, 2026.
  24. Goodman Manufacturing. Service manual: *MES96*U Single Stage Ultra-Low NOx Gas Furnaces and Accessories. RS6612017R4, March 2023. Accessed Oct 19, 2026.
  25. Goodman Manufacturing. Service manual: 80% Single Stage Ultra-Low NOx Gas Furnaces GMES80*U* & AMES80*U* & Accessories. RS6621006R4, March 2023. Accessed Oct 19, 2026.
  26. Goodman Manufacturing. Service manual: Goodman Brand GRVT80/GDVT80 & Amana Brand ARVT80/ADVT80 80% Two Stage Gas Furnaces with Variable-Speed ECM Motor. RS6621305, January 2025. Accessed Oct 17, 2026.
  27. Goodman Manufacturing. Installation Instructions for *MVC80* & *CVC80* Gas Furnace. IOG-2023E, 07/2022. Accessed Oct 17, 2026.
  28. Goodman Manufacturing. Service manual: Goodman Brand GRVT96/GDVT96 & Amana Brand ARVT96/ADVT96 96% Two Stage Gas Furnaces with Variable-Speed ECM Motor. RS6612305, April 2025. Accessed Oct 17, 2026.
  29. Goodman Manufacturing. Service manual: 34.5" Chassis ACVC96*BA/AMVC96*BA GCVC96*BA/GMVC96*BA Gas Furnaces (BA revision & above). RS6612014, December 2017. Accessed Oct 17, 2026.
  30. Goodman Manufacturing. Service manual: 80% Single Stage Gas Furnaces GR9S80, AR9S80, GD9S80, AD9S80, VR9S80, VD9S80 & Accessories. RS6621301, November 2023. Accessed Oct 17, 2026.
  31. Goodman Manufacturing. Installation Instructions for *MSS9* & *CSS9* Single-Stage Gas Furnace. IOG-2009Q, 08/2022. Accessed Oct 19, 2026.
  32. Goodman Manufacturing. Installation Instructions for *MEC96 Upflow / Horizontal Two-Stage Gas Furnace. IOG-2011U, 02/2022. Accessed Oct 19, 2026.
  33. Goodman Manufacturing. Service manual: Goodman Brand GMEC80/GCEC80 & Amana Brand AMEC80/ACEC80 Two Stage Furnace with multi-speed ECM Motor. RS6621005R1, June 2020. Accessed Oct 19, 2026.
  34. Goodman Manufacturing. Service manual: *MES96*U Single Stage Ultra-Low NOx Gas Furnaces and Accessories. RS6612017, October 2019. Accessed Oct 17, 2026.
  35. Goodman Manufacturing. Service manual: 80% Single Stage Ultra-Low NOx Gas Furnaces GMES80*U* & AMES80*U* & Accessories. RS6621006, October 2019. Accessed Oct 17, 2026.