Fujitsu code A1: discharge temperature error
Fujitsu display
A1
“Discharge temperature error (Outdoor unit)”
What it means
Code A1 is a discharge temperature error. The A counts as ten blinks, so in the installation manuals’ lamp tables A1 is ten OPERATION blinks and one TIMER blink, repeated, while ECONOMY blinks fast KPAS Installation Manual, p. En-16; LZBS Installation Manual, p. En-11; RLS3 Installation Manual, p. En-12.
The outdoor unit’s main PCB stops the compressor when the discharge temperature reaches 230°F (110°C) or more during compressor operation. A1 is set when that protection stop happens twice within 24 hours KPAS/KPBS Service Manual SR_AS142ES_09, p. 03-64. In that manual’s mobile app table the code is A1.1, “Outdoor unit discharge temperature 1 error (permanent stop)” KPAS/KPBS Service Manual SR_AS142ES_09, p. 03-9. The RLS3 Service Instructions print the same 230°F (110°C), twice-in-24-hours rule p. 02-24.
The causes the manual lists KPAS/KPBS Service Manual SR_AS142ES_09, p. 03-64:
- a 3-way valve that is not open;
- a defective electronic expansion valve (EEV) or capillary tube, or a clogged strainer;
- an outdoor unit that does not operate properly, or foreign matter on its heat exchanger;
- a failed discharge temperature thermistor;
- insufficient refrigerant;
- a failed main PCB.
Check these first
Fujitsu’s owner’s manuals give no owner fix for this code. The steps are the same as for any code; the manuals’ wording is on the code 11 page.
- Check that it is an error code: OPERATION and TIMER blink while ECONOMY blinks fast KPAS Operation Manual, p. En-13.
- Read the code with Service check if your remote has it; it shows the A as a character KPAS Operation Manual, pp. En-13–En-14.
- Stop the unit, turn off its breaker and consult authorized service personnel, as the manuals require for this lamp pattern RLS3 Operation Manual, p. En-10; KPAS Operation Manual, p. En-12. This is separate from their rule against using the breaker for everyday on and off KPAS Operation Manual, p. En-2.
- Give them the code KPAS Operation Manual, p. En-14.
When to call a licensed technician
The KPAS/KPBS service manual’s checks for A1, in order KPAS/KPBS Service Manual SR_AS142ES_09, pp. 03-64–03-65:
- Whether the 3-way valve is open: the gas side for cooling, the liquid side for heating. If it is closed, open it and check operation.
- The electronic expansion valve, the capillary tube and the strainer.
- The outdoor fan and heat exchanger: foreign objects, whether the fan turns by hand, and the fan motor.
- The discharge temperature thermistor, checked with it disconnected from the PCB.
- The refrigerant amount, by checking for refrigerant leakage.
- If none of these improves the symptom, replace the main PCB.
Fujitsu’s service manual says anyone working on or breaking into a refrigerant circuit should hold a valid certificate KPAS/KPBS Service Manual SR_AS142ES_09, p. 02-1; in the US that is a technician certified under EPA Section 608. Fujitsu also warns of electric shock and sets a waiting time after power-off before electrical components are touched: 5 minutes in the service manual, 10 minutes in the KPAS installation manual KPAS/KPBS Service Manual SR_AS142ES_09, p. 02-1; KPAS Installation Manual, p. En-2.
Notes for different models
- The other K-series service manuals have their own sections for A1 KNAS Service Manual SR_AS159ES_02, pp. 03-58–03-59; KMAS Service Manual SR_AS134ES_03, pp. 03-54–03-55; KZAS Service Manual SR_AS137ES_03, pp. 03-61–03-62; KTAS Service Manual SR_AS147ES_04, pp. 03-60–03-61; ASLH Service Manual SR_AS143ES_03, pp. 03-48–03-49, and so do the L-series ones LZBS Service Manual SR_AS048EF_02, pp. 03-37–03-38; LZAS Service Manual SR_AS024EF_09, pp. 03-37–03-38; LMAS Service Manual SR_AS058EF_04, pp. 03-25–03-26; LPAS Service Manual SR_AS050EF_03, pp. 03-27–03-28. Their temperature limits are not repeated here.
- RLS3-era tables call it “Discharge temp. error” RLS3 Service Manual, p. 7, and their service instructions have a section for it RLS3Y Service Instruction, p. 02-29; RLB Service Instructions, p. 02-23; RLS2 Service Instructions, p. 02-24; RLFW1 Service Instruction, p. 02-22.
- 71, “Discharge thermistor error (Outdoor unit)”, is a separate code for the discharge thermistor; its checks are the connector, the thermistor’s resistance and the main PCB voltage KPAS/KPBS Service Manual SR_AS142ES_09, p. 03-49.
Related Fujitsu codes
See also
- Heat pump vs gas calculator
- R-410A after 2025: EPA rules for home AC and heat pumps
- HVAC and furnace tax credits in 2025 and 2026: 25C, 25D, 30C
Other ductless mini-splits: Daikin, Mitsubishi Electric, MrCool
Fujitsu is a trademark of its owner. How House Works is not affiliated with or endorsed by Fujitsu.
Sources
- GENERAL Inc.. KPAS/KPBS Service Manual SR_AS142ES_09. Document code SR_AS142ES_09, page stamp 2026.06.18; covers ASUH09–36KPAS/KPBS and AOUH09–36KPAS1. The 2026 revision. It adds code 45, which the earlier revision SR_AS142ES_04 does not list.. Accessed Oct 12, 2026.
- Fujitsu General America / GENERAL HVAC Solutions America (document portal). KPAS Installation Manual. PART No. 9387603408-01; KP series; no publication date printed. Accessed Oct 12, 2026.
- Fujitsu General America / GENERAL HVAC Solutions America (document portal). KPAS Operation Manual. PART No. 9387602548-01; KP series; no publication date printed. Accessed Oct 12, 2026.
- Fujitsu General Limited. KNAS Service Manual SR_AS159ES_02. Document code SR_AS159ES_02, page stamp 2025.10.08; covers ASUH09–24KNAS and AOUH09–24KNAS1. Accessed Oct 12, 2026.
- Fujitsu General Limited. KMAS Service Manual SR_AS134ES_03. Document code SR_AS134ES_03, page stamp 2024.11.11; covers ASUH09/12KMAS and AOUH09/12KMAS1. Accessed Oct 12, 2026.
- Fujitsu General Limited. KZAS Service Manual SR_AS137ES_03. Document code SR_AS137ES_03, page stamp 2025.01.09; covers ASUH09–24KZAS and AOUH09–24KZAH1. Accessed Oct 12, 2026.
- Fujitsu General Limited. KTAS Service Manual SR_AS147ES_04. Document code SR_AS147ES_04, page stamp 2025.07.30; titled Service Manual for Cold Climate Region; covers ASUH09/12/15KTAS and KTAB with AOUH09/12/15KTAP1. Accessed Oct 12, 2026.
- Fujitsu General Limited. ASLH Service Manual SR_AS143ES_03. Document code SR_AS143ES_03, page stamp 2024.11.11; covers ASLH09/12KNAS and AOLH09/12KNAS1, 115 V. Its code table prints blink counts only, with no wired remote controller code column.. Accessed Oct 12, 2026.
- Fujitsu General Limited. LZBS Service Manual SR_AS048EF_02. Document code SR_AS048EF_02, page stamp 2022.10.14; covers ASUG09–15LZBS and AOUG09–15LZAS1. Accessed Oct 12, 2026.
- Fujitsu General America / GENERAL HVAC Solutions America (document portal). LZBS Installation Manual. PART No. 9387603187; no publication date printed. Accessed Oct 12, 2026.
- Fujitsu General Limited. LZAS Service Manual SR_AS024EF_09. Document code SR_AS024EF_09, page stamp 2022.10.12; covers ASUG09–15LZAS and AOUG09–15LZAS1. Accessed Oct 12, 2026.
- Fujitsu General Limited. LMAS Service Manual SR_AS058EF_04. Document code SR_AS058EF_04, page stamp 2022.10.05; covers ASUH09/12LMAS and AOUH09/12LMAS1. Accessed Oct 12, 2026.
- Fujitsu General Limited. LPAS Service Manual SR_AS050EF_03. Document code SR_AS050EF_03, page stamp 2022.10.18; covers ASUH09/12LPAS and AOUH09/12LPAS1. Accessed Oct 12, 2026.
- Fujitsu General America / GENERAL HVAC Solutions America (document portal). RLS3 Service Manual. No document code printed; the error table page is stamped 2015.01.06; covers ASU9/12RLS3 and AOU9/12RLS3. Accessed Oct 12, 2026.
- Fujitsu General America / GENERAL HVAC Solutions America (document portal). RLS3 Service Instructions. No document code or date printed; covers ASU9/12/15RLS3 and AOU9/12/15RLS3. Accessed Oct 12, 2026.
- Fujitsu General America / GENERAL HVAC Solutions America (document portal). RLS3 Installation Manual. PART No. 9320456016; no publication date printed. Accessed Oct 12, 2026.
- Fujitsu General America / GENERAL HVAC Solutions America (document portal). RLS3 Operation Manual. PART No. 9320455026; no publication date printed. Accessed Oct 12, 2026.
- Fujitsu General America / GENERAL HVAC Solutions America (document portal). RLS3Y Service Instruction. No document code or date printed; covers ASU9/12/15RLS3Y and AOU9/12/15RLS3. The cover is stamped “TENTATIVE”.. Accessed Oct 12, 2026.
- Fujitsu General America / GENERAL HVAC Solutions America (document portal). RLB Service Instructions. No document code or date printed; covers ASU18/24RLB and AOU18/24RLB. Accessed Oct 12, 2026.
- Fujitsu General America / GENERAL HVAC Solutions America (document portal). RLS2 Service Instructions. No document code or date printed; covers ASU9/12/15RLS2 and AOU9/12/15RLS2. Accessed Oct 12, 2026.
- Fujitsu General America / GENERAL HVAC Solutions America (document portal). RLFW1 Service Instruction. No document code or date printed; covers ASU9/12RLF1 and AOU9/12RLFW1. Accessed Oct 12, 2026.