Carrier furnace code 14 (1 short, 4 long): ignition lockout
Furnace control LED
14
“IGNITION LOCKOUT”
Printed on 21 model series · 31 documents
What it means
Code 14 is one short flash followed by four long ones. Every two-digit label calls it “IGNITION LOCKOUT”: the control will auto-reset after three hours, and the label sends you to code 34 for the causes 59SC5A-13SI, p. 67. Code 34 is a failed attempt to prove flame; 14 is the lockout after the last attempt 59SC5A-13SI, p. 67.
The documents count the attempts in different words but all come to four. Carrier’s owner’s manual for condensing furnaces says the control locks out if the main burners fail to ignite after four attempts OM9GFRC-02, p. 6; its 80% manual describes three more ignition cycles after the burners first fail to ignite 80GSFRN-C-03OM, p. 5. On the 59TP6C, if the flame is not proved within two seconds, the control closes the gas valve and repeats the ignition sequence for up to three more trials before ignition lockout 59TP6C-01SI, p. 71.
Check these first
The owner’s manual has a direct instruction for this case: “If lockout occurs, main burners fail to light, or blower does not come on, shut down the furnace and call your dealer for service.” OM9GFRC-02, p. 6. Carrier’s 80% manual gives the same instruction if lockout occurs or the blower does not come on 80GSFRN-C-03OM, p. 5. Separately, the 34 label lists a closed manual valve and a gas valve that is turned off among the causes 59SC5A-13SI, p. 67, and the owner’s checklist for a furnace that fails to operate lets you check both:
- Write the code down before you turn off the power or remove the blower access door OM9GFRC-02, p. 10. Carrier’s 80% owner’s manual does not mention the LED. How to count the flashes: reading a Carrier code.
- Check that the manual shut-off valve in the gas supply pipe leading to the furnace is open OM9GFRC-02, p. 11. Carrier’s 80% manual explains the handle: it is open when the lever points the same way as the pipe and closed when it is at a right angle to the pipe 80GSFRN-C-03OM, p. 7.
- Check that the control switch on the gas valve is in the ON position. The switch is behind the furnace door: first turn off the electrical power supply to the furnace and install a lockout tag before removing the access doors OM9GFRC-02, pp. 10–11; Carrier’s 80% manual says to turn off the electrical power supply and remove the access door before this check 80GSFRN-C-03OM, p. 7. If you must reset the switch to ON, the manual says to follow the start-up procedure OM9GFRC-02, p. 11. That procedure has you set the switch to OFF, wait five minutes and smell for gas, including near the floor, and stop if you smell gas, before you set it to ON OM9GFRC-02, pp. 4–6.
- In the 80% manual, if either check shows an interruption in the gas supply, make sure the gas has not been shut off for safety reasons; if nothing else seems to be wrong, follow the start-up procedures on pages 3 and 4 of that booklet 80GSFRN-C-03OM, p. 7.
- Never try to light the burners with a match or other source of flame OM9GFRC-02, p. 4; 80GSFRN-C-03OM, p. 3.
- If the valve was open and the switch was on, follow the lockout instruction: shut down the furnace and call your dealer OM9GFRC-02, p. 6.
When to call a licensed technician
- The lockout comes back, or the main burners still fail to light OM9GFRC-02, p. 6.
- The other causes on the 34 label: oxide on the flame sensor, the flame sense current, control ground continuity and the green/yellow wire to the furnace sheet metal, a grounded flame sensor, a defective hot surface igniter, a defective gas valve, low inlet gas pressure, and inadequate flame carryover or rough ignition 59SC5A-13SI, p. 67. See the code 34 page.
- The owner’s manual lets untrained people clean and replace air filters and says all other operations must be performed by trained service personnel OM9GFRC-02, p. 2.
Notes for different models
- Labels word the retries differently: “three more times” on most, “four ignition trials” on the Bryant 820SA and the 58TP0A, and “ignition four times” on the 59SU5A, Bryant 935SA, 59CU5A and Payne PG80ESU 59SC5A-13SI, p. 67; II820SA-02, p. 26; 58TP0A-02SI, p. 37; 59SU5A-05SI, p. 51; GFULN80-G-01TS, p. 6.
- Boards with a 3-digit display split the lockout: 14.1, “Ignition Lockout after 4 consecutive ignition tries”; 14.2, “Flame lost 3 times after 70s of heating”; 14.3, “Lockout - 7 loss of flame events during a heat request” 59TP6C-01SI, p. 56; IM-PG96VTAB-01, p. 54; 58SP0B-01SI, p. 30; II800SB-01, p. 31. On the 59TP6C, 59TP7A, Bryant 926TC and Payne PG96VTAB, 14.4 is “Lockout - 7 LPS open events during a heat request”, a pressure switch lockout; see code 32 59TP6C-01SI, p. 56; IM-PG96VTAB-01, p. 54.
- On the Bryant 935SB, 14.3 adds “or three 34.4 faults during heat request”, and 14.4 is “Lockout – 7 loss of pressure events during a heat request” II935SB-01, p. 48.
- The 58SU0A has no code 14. Its 1 red flash is “System Lockout: Retries Exceeded, 1 Hour Fixed”, and its checks start with no gas or the gas valve OFF 58SU0A-05SI, p. 36.
- The Infinity zone control lists furnace code 14; for 14 the system heats only with the heat pump, if there is one, until the code clears UIZ01-07SI, p. 20.
Related Carrier codes
See also
Other gas furnaces: Goodman, Lennox, Rheem and Ruud
Carrier is a trademark of its owner. How House Works is not affiliated with or endorsed by Carrier.
Sources
- Carrier Corporation. Owner's Manual, Condensing Gas Furnace. OM9GFRC-02, edition 04/20; replaces OM9GFRC-01. Accessed Oct 17, 2026.
- Carrier Corporation. Owner's Manual, Non-Condensing, 80% AFUE Gas Furnace. 80GSFRN-C-03OM, edition 08/22; replaces OM8GFRC-02. Accessed Oct 17, 2026.
- Carrier Corporation. SYSTXCCUIZ01--V Infinity Control (Zone), Installation Instructions. UIZ01-07SI, edition 05/12; replaces UIZ01-06SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58PAV, 58RAV Induced-Combustion Furnaces, Service and Maintenance Instructions, Sizes 045-155, Series 131. Form 58P,R-9SM (Catalog No. 535-835), edition 9-94; replaces 58P,R-8SM. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58MCB 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace, Service and Maintenance Instructions, Sizes 040-120, Series 110 & 120. 58MCB-4SM, edition 10/09; replaces 58MCB-3SM. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58STA/STX Single-Stage Deluxe, Induced-Combustion 4-Way Multipoise Gas Furnace, Series 160. 58ST-24SI, edition 08/13; replaces 58ST-23SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Payne Heating & Cooling. PG8MAA/PG8JAA Series G: Single-Stage Deluxe, Induced-Combustion 4-Way Multipoise Gas Furnace. IM-PG8J-17, edition 08/13; replaces IM-PG8J-16. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58SC0A/58SC1A: 80% AFUE, Single-Stage, Multi-Speed ECM, 4-Way Multipoise, Non-Condensing Gas Furnace. 58SC0A-05SI REV B, edition 09/21; replaces 58SC0A-05SI REV A. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58SB0A/58SB1A: Single Stage, Multi-Speed ECM, Non-Condensing Gas Furnace, Input Capacities 45,000 thru 155,000 Btuh. 58SB0A-04SI, edition 03/20; replaces 58SB0A-03SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 810SA/811SA: 80% AFUE, Single-Stage, Multi-Speed ECM, 4-Way Multipoise, Non-Condensing Gas Furnace. II810SA-05 REV B, edition 09/21; replaces II810SA-05 REV A. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Payne Heating & Cooling. PG80ESAA/PG80ESLA: 80% AFUE, Single-Stage, Multi-Speed ECM, 4-Way Multipoise, Non-Condensing Gas Furnace. IM-PG80ESA-05 REV B, edition 08/21; replaces IM-PG80ESAA-05 REV A. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Payne Heating & Cooling. PG80ESAA/PG80ESLA: Single Stage, Multi-Speed ECM, Non-Condensing Gas Furnace, Input Capacities 45,000 thru 155,000 Btuh. IM-PG80ESAA-04, edition 03/20; replaces IM-PG80ESAA-03. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 820SA/821SA: 80% AFUE, Non-Communicating, Single Stage, ECM Motor, Variable Speed, 4-Way Multipoise, Non-Condensing Gas Furnace. II820SA-02 REV A, edition 08/21; replaces II820SA-02. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58TP0A/58TP1A Variable-Speed, ECM Induced-Combustion, 2-Stage 4-Way Multipoise, Non-Condensing Gas Furnace, Series A. 58TP0A-02SI, edition 07/19; replaces 58TP0A-01SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58TN0A/58TN1A: 80% AFUE, Two-Stage, Variable-Speed 4-Way Multipoise, Non-Condensing Gas Furnace, Series A. 58TN0A-02SI REV A, edition 08/21; replaces 58TN0A-02SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 880TA/881TA: 80% AFUE, Two-Stage, Variable-Speed 4-Way Multipoise, Non-Condensing Gas Furnace, Series A. II880TA-02 REV A, edition 08/21; replaces II880TA-02. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SC2D Single Stage, 35-in. (889 mm) Tall 4-Way Multipoise Condensing Gas Furnace. 59SC2D-02SI, edition 11/19; replaces 59SC2D-01BSI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SC5A Single Stage 4-Way Multipoise Condensing Gas Furnace, Series 1 and 2. 59SC5A-13SI, edition 01/19; replaces 59SC5A-12SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SP5A Single Stage, 4-Way Multipoise Condensing Gas Furnace, Series 1 and 2. 59SP5A-18SI, edition 01/19; replaces 59SP5A-17SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SC5B: Single-Stage, High Efficiency, 4-Way Multipoise, 35-in. (889 mm), Condensing Gas Furnace. 59SC5B-04SI REV E, edition 06/23; replaces 59SC5B-04SI REV D. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SP6A: Single-Stage, Non-Communicating, Variable-Speed, ECM Multipoise, Condensing Gas Furnace. 59SP6A-01SI REV D, edition 06/23; replaces 59SP6A-01SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59TP6A Two-Stage Variable Speed ECM Multipoise Condensing Gas Furnace, Series 2, All Series 3 80-20, 100-20, 120-22. 59TP6A-10SI, edition 11/18; replaces 59TP6A-09SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59TP6B: Installation, Start-up, Operating and Service and Maintenance Instructions. 59TP6B-04SI REV D, edition 06/23; replaces 59TP6B-04SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 19, 2026.
- Payne Heating & Cooling. PG96VAT: Two-Stage 4-Way Multipoise Condensing Gas Furnace, Series B, All Series C, Sizes 60080, 60100, 66120. IM-PG96VAT-13, edition 11/18. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59TN6B: Two-Stage, Variable-Speed, Multipoise, 35 in. (889 mm) Tall, Condensing Gas Furnace. 59TN6B-01SI REV D, edition 06/23; replaces 59TN6B-01SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 986TC: Two-Stage, Variable-Speed, Multipoise, 35 in. (889 mm) Tall, Condensing Gas Furnace. II986TC-01 REV D, edition 06/23; replaces II986TC-01 REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59MN7B: Modulating, High Efficiency Condensing Gas Furnace, 4-Way Multipoise. 59MN7B-02SI REV D, edition 06/23; replaces 59MN7B-02SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59SU5A: Up to 95% AFUE, Single-Stage, Upflow/Horizontal, Ultra Low NOx, 35-in. Tall, Condensing Gas Furnace (Minor Series 2). 59SU5A-05SI REV D, edition 06/23; replaces 59SU5A-05SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 935SA: Up to 95% AFUE, Single-Stage, Upflow/Horizontal, Ultra Low NOx, 35-in. Tall, Condensing Gas Furnace (Minor Series B). II935SA-05 REV D, edition 06/23; replaces II935SA-05 REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59CU5A: Single-Stage, Upflow/Horizontal Communicating, Variable Speed ECM, Ultra Low NOx, 35-in Tall Condensing Gas Furnace. 59CU5A-01SI REV D, edition 06/23; replaces 59CU5A-01SI REV C. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58SU0A 4-Way Multipoise, Ultra Low NOx 80% AFUE Gas Furnace, Input Capacities 40,000 thru 100,000 Btuh. 58SU0A-05SI, edition 11/19; replaces 58SU0A-04SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Payne Heating & Cooling. PG80ESU (Minor Series B&C) Troubleshooting Guide: 80% AFUE, Ultra Low NOx, 4-Way Multipoise Gas Furnace. GFULN80-G-01TS, edition 08/23. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. Troubleshooting Guide: Mid-Efficiency Variable-Speed, Two-Stage Induced-Combustion Deluxe, 4-Way Multipoise Gas Furnace. TG-GFC80-02, edition 05/18; replaces TG-GFC80-01. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 59MN7A Series 100 Troubleshooting Guide: Variable Speed, Modulating Electronic Condensing Four-Way Multipoise Gas Furnace. Form 59MN7A-01T, edition 9-11. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 19, 2026.
- Carrier Corporation. 58MVP Series 170 & 180, 58MVB, 58UVB Troubleshooting Guide: Variable Speed, Two-Stage Electronic Condensing Gas Furnace. Form 58-06T, edition 6-08; replaces 58MVP-10SM. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 19, 2026.
- Carrier Corporation. 59TP6C: Two-Stage, Non-Communicating, Variable 25-Speed, ECM Multipoise, Condensing Gas Furnace with InteliSense. 59TP6C-01SI REV A, edition 06/23; replaces 59TP6C-01SI. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Payne Heating & Cooling. PG96VTAB: Two-Stage, Non-Communicating, Variable 25-Speed, ECM Multipoise, Condensing Gas Furnace. IM-PG96VTAB-01 REV A, edition 06/23; replaces IM-PG96VTAB-01. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Carrier Corporation. 58SP0B/58SP1B: 80% AFUE, Non-Communicating, Single Stage, Variable 25-Speed, ECM Motor, 4-Way Multipoise, Non-Condensing Gas Furnace with InteliSense. 58SP0B-01SI, edition 03/23. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 800SB/801SB: 80% AFUE, Single Stage, Multi-Speed ECM, 4-Way Multipoise, Non-Condensing Gas Furnace. II800SB-01 REV B, edition 06/23; replaces II800SB-01 REV A. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 17, 2026.
- Bryant Heating & Cooling Systems. 935SB: Installation, Start-up, Operating and Service Maintenance Instructions (single-stage ultra low NOx condensing; 3-digit display). II935SB-01 REV C, edition 06/23; replaces II935SB-01 REV B. Manufacturer PDF hosted on shareddocs.com, not on the brand website.. Accessed Oct 19, 2026.